• Foxboro FBM207 P0916AL I/A Series 200 Compression Termination Assembly
  • Foxboro FBM207 P0916AL I/A Series 200 Compression Termination Assembly
  • Foxboro FBM207 P0916AL I/A Series 200 Compression Termination Assembly
  • Foxboro FBM207 P0916AL I/A Series 200 Compression Termination Assembly
Product Overview The Foxboro FBM207 P0916AL is an I/A Series 200 Compression Termination Assembly used to organize and terminate field wiring associated with the FBM207 interface. It provides the physic……
Foxboro FBM207 P0916AL I/A Series 200 Compression Termination Assembly
  • Foxboro
  • FBM207 P0916AL
  • Compression Termination Assembly
  • USA
  • 127 × 80 × 125 mm
  • 0.272 kg
  • Xiamen, China
  • New & In Stock
  • T/T, PayPal, Western Union
  • 1 Year
  • 1-3 Working Days
  • DHL, UPS, TNT, FedEx and EMS.
  • 24-Hour Service
  • COO
  • 6

Our advantage

Foxboro FBM207 P0916AL I/A Series 200 Compression Termination Assembly

Global Logistics

We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.

Foxboro FBM207 P0916AL I/A Series 200 Compression Termination Assembly

Brand new and original

Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.

Foxboro FBM207 P0916AL I/A Series 200 Compression Termination Assembly

24-hour service

We provide 7*24 hours service to our customers. We will be there whenever you need us.

Foxboro FBM207 P0916AL I/A Series 200 Compression Termination Assembly

Price advantage

All our products are priced very favorably because we have our own warehouse and supply.


Company Information
E-mail [email protected]
Mobile +8615980777398
Whatsapp +8615980777398
WeChat 15980777398

Product Overview

The Foxboro FBM207 P0916AL is an I/A Series 200 Compression Termination Assembly used to organize and terminate field wiring associated with the FBM207 interface. It provides the physical connection point between field-side conductors and the corresponding I/O interface circuitry, helping keep signal wiring arranged in a controlled and serviceable manner.

In a typical Foxboro I/A Series 200 installation, the P0916AL is used where field devices need to be connected through a dedicated compression-style termination arrangement. The assembly is particularly useful during panel construction, commissioning, and later maintenance because individual field circuits can be accessed without disturbing unrelated wiring.

The termination assembly works as part of the overall I/O connection path rather than as an independent signal-processing module. Its role is concentrated on field wiring termination, signal routing, and maintaining an organized interface between the plant wiring and the FBM207 control-system hardware.


Technical Specifications

Parameter Specification
Product Model P0916AL
Product Type Compression Termination Assembly
Series I/A Series 200
Associated FBM FBM207
Termination Type Compression Termination
Dimensions 127 × 80 × 125 mm
Weight 0.272 kg

Product Features

  • Compression-style field termination — Provides a structured termination point for field conductors associated with the FBM207 I/O interface.
  • I/A Series 200 integration — Intended for use within the Foxboro I/A Series 200 I/O connection architecture.
  • Organized field wiring — Keeps incoming field circuits grouped at a defined termination location instead of routing individual conductors directly to the electronic interface.
  • Service-oriented connection layout — Makes wiring inspection, troubleshooting, and reconnection more manageable during plant maintenance.
  • Panel installation suitability — Fits the type of structured wiring arrangement commonly used in distributed control system cabinets and I/O panels.
  • Dedicated interface function — Concentrates on field termination and signal interconnection rather than performing the signal-conditioning or control functions of the FBM itself.

Working Principle

The P0916AL sits on the field-wiring side of the FBM207 connection path. Field conductors are brought to the compression termination assembly and secured at their designated connection points. From there, the terminated circuits are routed toward the associated I/O interface.

During normal operation, the assembly does not execute the control logic or independently interpret process signals. Its function is to maintain the electrical connection between field wiring and the FBM207-side interface in an orderly and serviceable form.

For commissioning work, technicians can trace individual field circuits from the termination point toward the corresponding I/O channel. During maintenance, this arrangement also helps isolate wiring-related issues from faults occurring within the electronic I/O module or the control-system communication network.


Role in a Foxboro I/A Series 200 I/O Control Architecture

Architecture Layer Role of P0916AL
Field Devices Provides the termination point for incoming field wiring
Field Wiring Organizes and secures individual conductors
Compression Termination Establishes the physical connection between field circuits and the I/O interface path
FBM207 Interface Routes the terminated circuits toward the associated FBM207
I/A Series 200 System Supports the physical field-I/O connection used by the distributed control architecture
Maintenance Gives technicians an accessible point for wiring checks and circuit tracing

The P0916AL therefore belongs to the physical I/O termination portion of the control architecture. It complements the FBM207 rather than replacing its electronic signal-processing function.


Industrial Applications

Application Typical Use
Process Control Panels Termination of field circuits associated with Foxboro I/O installations
Chemical Processing Organized field wiring for process measurement and control loops
Oil & Gas Systems Structured connection between field instrumentation and DCS I/O
Power and Utility Plants Panel-level termination for distributed field signals
Water and Wastewater Field wiring organization within centralized control cabinets
Plant Expansion Projects Adding or reorganizing field connections while maintaining a structured I/O layout
Maintenance and Retrofit Work Simplifying circuit identification and reconnection during service activities

Installation and Maintenance

  1. Verify the assembly model — Confirm that P0916AL is the correct termination assembly for the intended FBM207 installation before wiring begins.
  2. Review the cabinet drawings — Check the system wiring diagrams and termination schedules to identify each field circuit.
  3. Confirm power isolation — Follow the plant’s approved isolation procedure before connecting or removing field conductors.
  4. Inspect terminals — Check compression connection points for contamination, mechanical damage, or loose hardware before installation.
  5. Identify every conductor — Match wire labels with the termination schedule before making connections.
  6. Maintain wiring separation — Keep field conductors arranged according to the cabinet’s established routing and segregation practices.
  7. Secure conductors correctly — Ensure each conductor is properly seated in its assigned termination point without excessive mechanical force.
  8. Check circuit continuity — Verify the wiring path before connecting the associated electronic I/O equipment.
  9. Inspect the connection path — Confirm that the termination assembly, associated cabling, and FBM207 interface are correctly connected.
  10. Perform point-to-point verification — During commissioning, compare actual field wiring with the control-system I/O documentation.
  11. Check for loose connections during service — If an individual I/O point behaves unexpectedly, inspect the associated termination and field wiring before replacing electronic modules.
  12. Document wiring changes — Record any field-circuit modifications so future maintenance personnel have an accurate termination reference.

Related Components

Component Relationship
Foxboro FBM207 Associated I/A Series 200 I/O interface
I/A Series 200 I/O Base / Mounting Arrangement Provides the physical installation environment for the I/O hardware
Field Wiring Connects instruments and devices to the termination assembly
DCS I/O Cabinet Houses the termination and interface equipment
Field Instruments Supply or receive the process signals handled through the associated I/O path
I/O Documentation Defines channel assignments and field termination information

Recommended Related Models

Model Product Type Application Relationship
Foxboro FBM203 I/A Series 200 I/O Interface Module Related Series 200 I/O hardware for process signal interfacing
Foxboro FBM204 I/A Series 200 I/O Interface Module Suitable for applications requiring mixed analog signal interfacing
Foxboro FBM205 I/A Series 200 Redundant I/O Interface Module Used where redundant I/O architecture is required
Foxboro FBM206 I/A Series 200 Pulse Input Interface Module Related option for pulse or frequency-oriented field signals
Foxboro FBM207 I/A Series 200 I/O Interface Module Directly associated I/O hardware for this termination assembly

Key Advantages

  • Provides a dedicated field-wiring termination point for the FBM207 interface.
  • Keeps cabinet wiring structured and easier to trace.
  • Supports practical commissioning and maintenance work.
  • Fits the established Foxboro I/A Series 200 I/O architecture.
  • Separates field termination tasks from electronic I/O processing.
  • Helps simplify circuit identification during troubleshooting.

Technical FAQs

What is the function of the Foxboro P0916AL?

The P0916AL is a Compression Termination Assembly associated with the Foxboro FBM207 I/A Series 200 I/O interface. Its primary function is to provide an organized physical termination point for field wiring and connect those circuits with the associated I/O interface path.

Is the P0916AL itself an I/O signal-processing module?

No. The P0916AL is a termination assembly rather than the electronic I/O processing unit. Signal acquisition or interface functions are handled by the associated FBM hardware, while the P0916AL provides the field-side termination and connection arrangement.

What should be checked if an FBM207 channel has an unexpected field signal?

Start with the field device and wiring path, then inspect the corresponding termination point on the P0916AL. Point-to-point continuity, conductor identification, terminal condition, and the connection between the termination assembly and FBM207 should be checked before concluding that the electronic I/O module has failed.

Can the P0916AL be replaced independently during maintenance?

Replacement should be based on the actual cabinet configuration and Foxboro I/A Series 200 wiring documentation. Before removing the assembly, field circuits should be identified and isolated according to site procedures, and the replacement should match the required FBM207 termination arrangement.



Related Products

Get the latest price? We will reply as soon as possible (within 12 hours)

No:77501