Product Overview The Honeywell 05701-A-0405 is a System 57 Series 16-Way AC to DC Power Supply Unit used to supply DC power to associated gas detection and monitoring equipment. It forms part of the pow……
Honeywell 05701-A-0405 System 57 Series 16-Way AC to DC Power Supply Unit
  • Honeywell
  • 05701-A-0405
  • AC to DC Power Supply Unit
  • USA
  • 350 × 60 × 208 mm
  • 1.5 kg
  • Xiamen, China
  • New & In Stock
  • T/T, PayPal, Western Union
  • 1 Year
  • 1-3 Working Days
  • DHL, UPS, TNT, FedEx and EMS.
  • 24-Hour Service
  • COO
  • 4

Our advantage

Honeywell 05701-A-0405 System 57 Series 16-Way AC to DC Power Supply Unit

Global Logistics

We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.

Honeywell 05701-A-0405 System 57 Series 16-Way AC to DC Power Supply Unit

Brand new and original

Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.

Honeywell 05701-A-0405 System 57 Series 16-Way AC to DC Power Supply Unit

24-hour service

We provide 7*24 hours service to our customers. We will be there whenever you need us.

Honeywell 05701-A-0405 System 57 Series 16-Way AC to DC Power Supply Unit

Price advantage

All our products are priced very favorably because we have our own warehouse and supply.


Company Information
E-mail [email protected]
Mobile +8615980777398
Whatsapp +8615980777398
WeChat 15980777398

Product Overview

The Honeywell 05701-A-0405 is a System 57 Series 16-Way AC to DC Power Supply Unit used to supply DC power to associated gas detection and monitoring equipment. It forms part of the power-distribution layer within a System 57 installation, supporting multiple connected circuits from an AC source.

The unit is suited to gas detection systems where several field or system devices require centralized DC power. A multi-way power arrangement can simplify the organization of power connections in installations containing multiple detectors, interface modules, indication equipment, or other System 57 components.

Within the overall system, the power supply operates independently from the gas sensing function. Its role is to convert the incoming AC supply into the required DC power for connected equipment, while the System 57 control and interface modules handle detection, monitoring, alarm processing, and associated system functions.

For maintenance personnel, the power supply should be considered when several System 57 channels or devices experience simultaneous loss of operation. Checking the incoming AC supply, DC output, connected loads, and individual distribution circuits can help distinguish a power-distribution problem from a fault in a specific detector or interface module.


Technical Specifications

Parameter Specification
Manufacturer Honeywell
Model 05701-A-0405
Product Family System 57 Series
Product Type 16-Way AC to DC Power Supply Unit
Primary Function AC-to-DC power conversion and distribution
System Role System power supply
Application Gas detection and industrial safety systems
Dimensions 350 × 60 × 208 mm
Weight 1.5 kg

Product Features

  • System 57 Series 16-way AC to DC power supply unit.
  • Converts incoming AC power for use by compatible DC-powered system equipment.
  • Provides multiple power distribution paths within the gas detection architecture.
  • Suitable for centralized power arrangements in System 57 installations.
  • Supports installations containing multiple detection and monitoring devices.
  • Helps organize power connections within control and instrumentation systems.
  • Suitable for maintenance, expansion, and replacement of existing System 57 power equipment.
  • Works as part of the complete System 57 power and monitoring infrastructure.

Working Principle

The 05701-A-0405 receives AC electrical power and converts it into DC power for distribution to connected System 57 equipment and associated circuits.

AC Power Source → 05701-A-0405 → DC Power Distribution → System 57 Modules / Field Equipment

The multiple output paths allow several connected circuits to receive power from the centralized supply arrangement. The individual loads then use the supplied DC power to operate their respective detection, interface, monitoring, or control functions.

The power supply does not perform gas detection or alarm decision-making itself. Its function is to maintain the electrical supply required by the equipment responsible for those functions.

When troubleshooting a system-wide fault, loss of DC power can be distinguished from an individual device fault by checking whether multiple connected channels are affected simultaneously. The incoming AC supply, power conversion stage, distribution paths, and connected loads should be evaluated as a complete power chain.


Role in a Honeywell System 57 Gas Detection Architecture

The 05701-A-0405 occupies the power-supply layer of the System 57 architecture. It supports the electrical supply requirements of multiple connected system and field devices, allowing the gas detection infrastructure to operate from a centralized power arrangement.

AC Supply → 05701-A-0405 → DC Distribution → System 57 Modules → Gas Detectors / Alarm Equipment

System Element Function
AC Power Source Supplies incoming electrical power
05701-A-0405 Converts AC power and distributes DC power
System 57 Modules Performs gas detection interface and monitoring tasks
Gas Detectors Detects target gas conditions
Alarm / Indication Devices Reports configured alarm and fault conditions
Safety System Provides higher-level safety response where integrated

A stable power supply is essential to the operation of the connected detection and monitoring channels. Simultaneous faults across several channels can therefore justify checking the centralized power-distribution path before investigating individual field devices.


Industrial Applications

Application Typical Use
Oil and Gas Facilities Centralized DC supply for gas detection equipment
Chemical Plants Power distribution for distributed gas monitoring
Process Plants System power for detection and alarm infrastructure
Power Generation Facilities Gas detection system power distribution
Industrial Utility Areas Supply for multiple detection and monitoring circuits
Hazardous Process Areas Centralized power support for gas detection systems
Large Industrial Facilities Multi-channel System 57 power distribution

Installation and Maintenance

  1. Confirm that the 05701-A-0405 is compatible with the installed System 57 power architecture.
  2. Isolate the incoming AC supply before installation or maintenance.
  3. Verify the approved electrical schematic before connecting the power supply.
  4. Check the incoming AC wiring and protective devices before energizing the unit.
  5. Confirm the intended DC distribution connections for each connected circuit.
  6. Inspect terminals and wiring for loose connections, damage, or signs of overheating.
  7. Verify that connected loads are suitable for the installed power-distribution arrangement.
  8. Energize the unit under controlled commissioning conditions and verify the expected DC supply.
  9. Check individual distribution paths when a connected System 57 device fails to operate.
  10. Investigate simultaneous equipment failures by checking the centralized power supply before replacing individual modules.
  11. Inspect the power supply and associated wiring for abnormal heating, intermittent operation, or physical damage during maintenance.
  12. After replacement, verify the DC power distribution and operation of all affected System 57 equipment before returning the gas detection system to normal service.

Compatible System Components

Component Function
Honeywell System 57 Gas detection and monitoring platform
System 57 Interface Modules Interfaces field detection equipment with the system
System 57 Gas Detectors Detects target gas conditions
Field Junction Equipment Distributes field wiring and power connections
Alarm Indicators Provides visual or audible alarm indication
Gas Detection Controllers Processes detection and system-status information
DC Distribution Circuits Transfers supplied power to connected equipment
Safety System Interface Transfers configured safety-related signals

Recommended Related Models

Model / Product Family Product Type Typical Application
Honeywell System 57 Series Gas Detection System Industrial gas detection and monitoring
Honeywell System 57 Modules Gas Detection Modules Detector interface and signal processing
Honeywell System 57 Cards Interface / Control Cards System-level gas detection functions
Honeywell System 57 Power Supplies Power Supply Unit System DC power distribution
Honeywell System 57 Field Interfaces Field Interface Card Detector and field signal connection
Honeywell Gas Detectors Gas Detection Device Combustible and toxic gas detection
Honeywell Alarm Modules Alarm Interface Gas alarm indication and control

Key Advantages

  • Provides centralized AC-to-DC power conversion for System 57 equipment.
  • Supports multiple connected power circuits within a gas detection installation.
  • Helps organize power distribution across distributed detection equipment.
  • Useful when several System 57 devices need to be supplied from a common power arrangement.
  • Simplifies troubleshooting of system-wide power-related faults.
  • Suitable for maintenance and replacement of existing System 57 power infrastructure.

Technical FAQs

Why can a failure of the 05701-A-0405 affect several System 57 devices at once?

The power supply serves multiple connected circuits. If the centralized DC supply or its distribution path is interrupted, several downstream devices may lose power simultaneously even though the individual detectors or interface modules remain functional.

What should be checked when only one System 57 device loses power?

Start with the specific distribution path serving that device. Check the associated wiring, terminals, protective elements, and connected load before assuming that the 05701-A-0405 itself has failed.

How should the AC-to-DC power supply be evaluated during commissioning?

The incoming AC supply should be verified first, followed by the resulting DC distribution and the operation of connected System 57 equipment. Testing representative output circuits helps confirm that the complete power path is functioning correctly.