• Honeywell 05701-A-0326 System 57 Series Field Interface Card
  • Honeywell 05701-A-0326 System 57 Series Field Interface Card
  • Honeywell 05701-A-0326 System 57 Series Field Interface Card
  • Honeywell 05701-A-0326 System 57 Series Field Interface Card
Product Overview The Honeywell 05701-A-0326 is a System 57 Series Field Interface Card used to connect field-level gas detection equipment with the associated System 57 control and monitoring infrastruc……
Honeywell 05701-A-0326 System 57 Series Field Interface Card
  • Honeywell
  • 05701-A-0326
  • Field Interface Card
  • USA
  • 160 × 30 × 130 mm
  • 0.23 kg
  • Xiamen, China
  • New & In Stock
  • T/T, PayPal, Western Union
  • 1 Year
  • 1-3 Working Days
  • DHL, UPS, TNT, FedEx and EMS.
  • 24-Hour Service
  • COO
  • 5

Our advantage

Honeywell 05701-A-0326 System 57 Series Field Interface Card

Global Logistics

We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.

Honeywell 05701-A-0326 System 57 Series Field Interface Card

Brand new and original

Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.

Honeywell 05701-A-0326 System 57 Series Field Interface Card

24-hour service

We provide 7*24 hours service to our customers. We will be there whenever you need us.

Honeywell 05701-A-0326 System 57 Series Field Interface Card

Price advantage

All our products are priced very favorably because we have our own warehouse and supply.


Company Information
E-mail [email protected]
Mobile +8615980777398
Whatsapp +8615980777398
WeChat 15980777398

Product Overview

The Honeywell 05701-A-0326 is a System 57 Series Field Interface Card used to connect field-level gas detection equipment with the associated System 57 control and monitoring infrastructure. It forms part of the interface layer between gas detection devices installed in the field and the central monitoring system.

The card is suited to installations where gas detectors and related field devices need to exchange signals with a centralized gas detection controller. Typical applications include industrial plants, process areas, utility facilities, and other locations where combustible or toxic gas monitoring is required.

A field interface arrangement allows detector signals and system information to be transferred into the System 57 architecture for monitoring, alarm handling, and control functions. The interface card works with the surrounding System 57 equipment rather than acting as a standalone gas detector.

For maintenance personnel, the 05701-A-0326 can be considered part of the signal path between field detection equipment and the monitoring system. Troubleshooting should therefore include the detector, field wiring, interface card, associated System 57 modules, and system configuration.


Technical Specifications

Parameter Specification
Manufacturer Honeywell
Model 05701-A-0326
Product Family System 57 Series
Product Type Field Interface Card
Primary Function Field gas-detection signal interface
System Role Gas detection system interface
Application Gas detection and industrial safety monitoring
Dimensions 160 × 30 × 130 mm
Weight 0.23 kg

Product Features

  • System 57 Series Field Interface Card.
  • Interfaces field gas-detection equipment with the System 57 control platform.
  • Supports organized signal exchange between detectors and central monitoring equipment.
  • Suitable for distributed gas detection installations.
  • Can be used as part of industrial gas monitoring and alarm systems.
  • Supports integration of field detection signals into a centralized safety-monitoring architecture.
  • Useful for maintenance and replacement of System 57 field-interface hardware.
  • Works as part of the complete System 57 system rather than as an independent gas detector.

Working Principle

The 05701-A-0326 operates within the field signal interface path of a System 57 installation. A connected gas detector or field device generates measurement or status information, which is transferred through the field wiring to the interface card and then into the associated System 57 monitoring equipment.

Gas Detector / Field Device → 05701-A-0326 → System 57 Control Equipment → Alarm / Monitoring System

The interface card does not itself perform the complete gas-detection process. Its function is to handle the connection between the field device and the system-level monitoring architecture.

When a detector reports a normal condition, alarm condition, fault, or other configured status, the corresponding information can be passed through the System 57 signal path for processing and indication. The actual alarm logic and system response depend on the connected System 57 equipment and configured application.


Role in a Honeywell System 57 Gas Detection Architecture

The 05701-A-0326 occupies the field-interface layer between gas detection devices and the System 57 control and monitoring equipment. This arrangement allows field detectors to be distributed throughout the protected area while their signals are brought into a centralized monitoring architecture.

Field Gas Detector → 05701-A-0326 → System 57 Control / Monitoring Equipment → Alarm & Safety Response

System Element Function
Gas Detector Detects the presence or concentration of target gas
Field Wiring Transfers detector signals to the system interface
05701-A-0326 Interfaces field detection signals with System 57
System 57 Control Unit Processes detection and system-status information
Alarm / Indication Reports configured gas alarms and system conditions
Plant Safety System Provides higher-level safety response where integrated

The interface card should be evaluated together with the detector and the complete System 57 communication or signal path when investigating abnormal readings or loss of detection channels.


Industrial Applications

Application Typical Use
Oil and Gas Facilities Field gas detection and centralized alarm monitoring
Chemical Plants Monitoring combustible or toxic gas hazards
Process Industries Distributed gas detector signal interfacing
Industrial Utility Areas Gas detection around equipment and service areas
Power Generation Facilities Gas monitoring in plant and equipment areas
Manufacturing Facilities Local gas detection connected to centralized monitoring
Safety-Critical Plant Areas Detector signal collection and alarm handling

Installation and Maintenance

  1. Confirm that the 05701-A-0326 is compatible with the installed System 57 configuration before replacement.
  2. Isolate the applicable gas detection system circuits according to the approved maintenance procedure.
  3. Record the existing field connections and card position before removing the installed unit.
  4. Verify detector wiring against the approved System 57 system documentation.
  5. Inspect terminal connections for loose conductors, damaged wiring, or signs of corrosion.
  6. Check the connected gas detector and field device before diagnosing the interface card itself.
  7. Ensure field wiring is properly supported and protected against mechanical damage.
  8. Verify that the associated System 57 control equipment is correctly powered and operating.
  9. Check detector status and system indications after installing or replacing the card.
  10. Test representative normal, alarm, and fault conditions using an approved gas-detection commissioning procedure.
  11. Investigate abnormal detector signals by checking the field device, wiring, interface card, and System 57 configuration as separate parts of the signal path.
  12. After replacement, perform a complete functional test of the affected gas-detection channel before returning the safety-monitoring system to normal operation.

Compatible System Components

Component Function
Honeywell System 57 Gas detection control and monitoring platform
System 57 Gas Detector Detects target gas conditions in the protected area
Field Junction Box Provides field wiring and detector connection
Gas Detection Controller Processes detector information and system conditions
Alarm Indicator Provides visual or audible gas alarm indication
Relay / Output Interface Transfers configured alarm or control signals
Plant Safety System Performs higher-level safety actions when integrated
Field Power Supply Supplies operating power to associated field devices

Recommended Related Models

Model / Product Family Product Type Typical Application
Honeywell System 57 Series Gas Detection System Industrial gas detection and monitoring
Honeywell System 57 Modules Gas Detection Modules Detector signal processing and interface
Honeywell System 57 Cards Interface / Control Cards System-level gas detection functions
Honeywell Gas Detectors Gas Detection Device Combustible and toxic gas detection
Honeywell Gas Monitoring Gas Detection Equipment Plant-wide gas monitoring
Honeywell Alarm Modules Alarm Interface Gas alarm indication and control
Honeywell Safety Interfaces Safety Interface Integration with plant safety systems

Key Advantages

  • Connects field gas-detection equipment with the System 57 monitoring architecture.
  • Supports distributed detector installations within industrial facilities.
  • Provides an organized interface between field wiring and system-level gas monitoring.
  • Useful for centralized alarm and detector-status management.
  • Simplifies troubleshooting by establishing a defined field-to-system signal path.
  • Suitable for maintenance and replacement of existing System 57 installations.

Technical FAQs

What is the difference between the 05701-A-0326 and a gas detector?

The 05701-A-0326 is a Field Interface Card, not the sensing element itself. The gas detector performs the field detection function, while the interface card connects the detector-related signals with the System 57 control and monitoring infrastructure.

What could cause a System 57 channel to lose its detector signal?

Possible causes include a detector fault, damaged field wiring, loose terminals, power loss, interface-card problems, or an issue elsewhere in the System 57 signal path. The complete channel should be checked rather than assuming the interface card is the cause.

Why is the field interface important in a distributed gas detection system?

Field detectors are often installed throughout different areas of a plant while monitoring equipment is concentrated in control or safety cabinets. A field interface provides the connection point needed to transfer detector information into the centralized System 57 architecture.

What should be tested after replacing the 05701-A-0326?

Verify the field connections and System 57 configuration first. The affected detector channel should then be tested for normal status, alarm response, fault indication, and correct reporting at the central monitoring equipment before the system is returned to service.