• Schneider BMXDDO1602H Modicon X80 Discrete Output Module
  • Schneider BMXDDO1602H Modicon X80 Discrete Output Module
  • Schneider BMXDDO1602H Modicon X80 Discrete Output Module
  • Schneider BMXDDO1602H Modicon X80 Discrete Output Module
Product Overview The Schneider BMXDDO1602H Modicon X80 Discrete Output Module connects PLC control logic with discrete field equipment in a Modicon X80 automation system. It converts output commands gen……
Schneider BMXDDO1602H Modicon X80 Discrete Output Module
  • Schneider
  • BMXDDO1602H
  • Discrete Output Module
  • France
  • 100 × 32 × 86 mm
  • 0.12 kg
  • Xiamen, China
  • New & In Stock
  • T/T, PayPal, Western Union
  • 1 Year
  • 1-3 Working Days
  • DHL, UPS, TNT, FedEx and EMS.
  • 24-Hour Service
  • COO
  • 5

Our advantage

Schneider BMXDDO1602H Modicon X80 Discrete Output Module

Global Logistics

We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.

Schneider BMXDDO1602H Modicon X80 Discrete Output Module

Brand new and original

Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.

Schneider BMXDDO1602H Modicon X80 Discrete Output Module

24-hour service

We provide 7*24 hours service to our customers. We will be there whenever you need us.

Schneider BMXDDO1602H Modicon X80 Discrete Output Module

Price advantage

All our products are priced very favorably because we have our own warehouse and supply.


Company Information
E-mail [email protected]
Mobile +8615980777398
Whatsapp +8615980777398
WeChat 15980777398

Product Overview

The Schneider BMXDDO1602H Modicon X80 Discrete Output Module connects PLC control logic with discrete field equipment in a Modicon X80 automation system. It converts output commands generated by the controller into discrete electrical states that can be used by relays, contactors, solenoid valves, indicator circuits, and other compatible devices.

In an X80 control cabinet, the module works with the PLC CPU and backplane to deliver output commands to equipment located in the machine or process area. The PLC determines when an output should change state based on sequencing, permissives, interlocks, operator commands, and feedback from input devices.

Typical applications include starting or stopping auxiliary equipment, operating solenoid valves, controlling relays, switching indication circuits, and sending discrete commands to other control devices. Output status can also be incorporated into machine sequences where a defined command must be maintained until a feedback condition is received.

During commissioning, technicians can test each output in a controlled state and compare the commanded output with the actual response of the connected equipment. This helps separate PLC logic issues from field wiring, load, or output-channel problems.


Technical Specifications

Parameter Specification
Manufacturer Schneider Electric
Model BMXDDO1602H
Product Family Modicon X80
Product Series BMXDDO
Product Type Discrete Output Module
Primary Function Discrete output signal control
System Role Digital output interface
Typical Application Machine and process automation
Installation Modicon X80 rack / control panel
Dimensions 100 × 32 × 86 mm
Weight 0.12 kg

Product Features

  • Modicon X80 discrete output module
  • Transfers PLC commands to discrete field circuits
  • Suitable for machine and process-control applications
  • Interfaces control logic with relays, contactors, valves, and indicators
  • Supports discrete equipment actuation
  • Integrates with the modular X80 I/O architecture
  • Suitable for sequencing, interlocking, and auxiliary control functions
  • Can operate alongside X80 CPU, input, analog, and communication modules

Working Principle

The BMXDDO1602H receives output commands from the PLC through the Modicon X80 backplane and changes the corresponding output state according to the control application.

PLC CPU → X80 Backplane → BMXDDO1602H → Output Circuit → Field Equipment

The PLC application determines whether an output should be activated or deactivated. The command is transferred to the output module, where the corresponding channel controls its connected discrete circuit.

For example, a PLC sequence may activate an output to energize a relay or solenoid valve. The resulting field action changes the state of the associated machine component. Feedback from an input module can then confirm whether the expected equipment condition has been achieved.

The BMXDDO1602H therefore forms the interface between software-based control logic and physical discrete equipment. It does not determine the operating sequence itself; the CPU and application program establish the conditions under which each output is commanded.


Role in a Modicon X80 Control Architecture

The BMXDDO1602H occupies the discrete output layer of the Modicon X80 control system. It receives processed commands from the PLC and transfers them to the appropriate field circuits.

Field Inputs → X80 Input Modules → CPU / PLC Logic → BMXDDO1602H → Field Actuators

System Element Function
Input Sensors / Switches Provides machine and process feedback
X80 Input Modules Acquires field conditions
X80 CPU Executes sequencing and control logic
X80 Backplane Transfers commands between rack modules
BMXDDO1602H Provides discrete output signals
Relays / Contactors Switches associated electrical circuits
Solenoid Valves / Actuators Performs the commanded physical action
HMI / SCADA Provides operator monitoring and command functions

This architecture allows the PLC application to control field equipment while keeping output switching separate from the higher-level control logic executed by the CPU.


Industrial Applications

Application Typical Use
Packaging Machinery Controlling solenoids, relays, and machine actuators
Assembly Equipment Operating discrete mechanisms and auxiliary devices
Conveyor Systems Controlling motor-related circuits and equipment functions
Machine Tools Switching valves, relays, and machine-control devices
Material Handling Operating discrete actuators and equipment commands
Pumping Systems Controlling auxiliary valves and switching devices
Process Automation Sending discrete commands to process equipment
Manufacturing Lines Executing machine sequence outputs and interlocks

Installation and Maintenance

  1. Install the BMXDDO1602H in the designated position within the Modicon X80 rack.
  2. Verify the rack configuration before connecting the module.
  3. Confirm the field-output wiring against the approved electrical drawings.
  4. Check terminal assignments and connected load circuits before energizing the system.
  5. Verify that each connected field device is appropriate for the intended output circuit.
  6. Test output channels individually during controlled commissioning.
  7. Confirm that the PLC command corresponds to the expected output-channel state.
  8. Check the associated relay, contactor, solenoid, or actuator when an output state does not produce the expected equipment response.
  9. Inspect field wiring and connections when multiple output channels show abnormal behavior.
  10. Review PLC logic, permissives, and interlocks when an output is not being commanded as expected.
  11. Follow the applicable electrical isolation procedure before replacing the module or modifying output wiring.
  12. After replacement, verify every required output channel, connected load, PLC sequence, interlock, and machine response before returning the system to service.

Related Components

Component Function
Schneider Modicon X80 Rack Provides module mounting and backplane communication
X80 CPU Module Executes PLC control logic
X80 Discrete Input Modules Acquires feedback from field devices
X80 Analog I/O Modules Handles analog process signals
X80 Communication Modules Provides industrial network connectivity
Relays Provides electrical switching between control and load circuits
Contactors Switches motor and other electrical loads
Solenoid Valves Converts discrete electrical commands into mechanical action
HMI Terminals Provides operator monitoring and command functions

Recommended Related Models

Model / Product Family Product Type Typical Application
Schneider Modicon X80 Modular Automation Platform PLC, I/O, and process-control systems
Schneider BMXDDO3202K X80 Discrete Output Module Discrete equipment control
Schneider BMXDDI3202K X80 Discrete Input Module Discrete field signal acquisition
Schneider BMXDDI3202KH X80 Discrete Input Module Digital input applications
Schneider BMXDDM16025 X80 Discrete Mixed I/O Module Combined digital input and output applications
Schneider BMXCPS3500 X80 Power Supply Module X80 rack power supply

Key Advantages

  • Provides a direct discrete output interface for Modicon X80 systems
  • Transfers PLC commands to compatible field equipment
  • Suitable for machine sequencing and equipment actuation
  • Supports relay, contactor, solenoid, and indication applications
  • Integrates with the modular X80 rack architecture
  • Simplifies separation of PLC logic from field output switching

Technical FAQs

What equipment can be controlled through BMXDDO1602H?

Typical applications include relays, contactors, solenoid valves, indicator circuits, and other compatible discrete loads. The connected load must be evaluated against the electrical requirements of the particular output channel and control-panel design.

Why does the PLC command an output but the field device remain inactive?

First verify that the PLC application is actually commanding the expected output. Then check the module status, field wiring, power supply, terminal connections, and connected load. A correct PLC command does not by itself confirm that the field circuit is functioning.

What is the difference between an output-module fault and an actuator fault?

If the PLC output status changes correctly but the connected equipment does not respond, inspect the field circuit and actuator. If the PLC does not command the output when all expected conditions are satisfied, investigate the application logic, permissives, interlocks, and controller configuration before replacing the output module.

What should be checked after replacing BMXDDO1602H?

Verify the module position and I/O configuration first, then check field wiring and output assignments. Test each required output under controlled conditions and confirm that the connected equipment responds correctly throughout the relevant machine sequence.



Related Products

Get the latest price? We will reply as soon as possible (within 12 hours)

No:77501