Product Overview The Emerson SE4033S2B1 DeltaV S-series Redundant Analog Input Card is an 8-channel redundant analog input solution for DeltaV S-series control systems. It is used to acquire continuous ……
Emerson SE4033S2B1 DeltaV S-series Redundant Analog Input Card
  • Emerson
  • SE4033S2B1
  • Redundant Analog Input Card
  • USA
  • 131 × 41.8 × 130.8 mm
  • 0.29 kg
  • Xiamen, China
  • New & In Stock
  • T/T, PayPal, Western Union
  • 1 Year
  • 1-3 Working Days
  • DHL, UPS, TNT, FedEx and EMS.
  • 24-Hour Service
  • COO
  • 57

Our advantage

Emerson SE4033S2B1 DeltaV S-series Redundant Analog Input Card

Global Logistics

We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.

Emerson SE4033S2B1 DeltaV S-series Redundant Analog Input Card

Brand new and original

Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.

Emerson SE4033S2B1 DeltaV S-series Redundant Analog Input Card

24-hour service

We provide 7*24 hours service to our customers. We will be there whenever you need us.

Emerson SE4033S2B1 DeltaV S-series Redundant Analog Input Card

Price advantage

All our products are priced very favorably because we have our own warehouse and supply.


Company Information
E-mail [email protected]
Mobile +8615980777398
Whatsapp +8615980777398
WeChat 15980777398

Product Overview

The Emerson SE4033S2B1 DeltaV S-series Redundant Analog Input Card is an 8-channel redundant analog input solution for DeltaV S-series control systems. It is used to acquire continuous 4–20 mA process signals from field transmitters while maintaining a redundant input path for applications where the loss of a single I/O card could affect process monitoring.

The SE4033S2B1 is intended for HART-capable analog instrumentation and supports both 2-wire and 4-wire transmitter applications. Typical signals come from pressure, temperature, flow, level, and other process transmitters used throughout distributed control systems.

The redundant configuration consists of two analog input cards together with a dedicated redundant 8-channel terminal block. The field signals are therefore presented to the DeltaV system through a paired input arrangement rather than a single card path.

HART communication also makes the module useful for intelligent field-instrument applications where process measurement and instrument information need to be handled through the same analog loop. Correct transmitter wiring, field power, terminal connections, and redundant-card configuration should be verified during commissioning and maintenance.


Technical Specifications

Parameter Specification
Product Type Redundant Analog Input Card
Product Series DeltaV S-series
Model SE4033S2B1
Number of Analog Inputs 8
Input Signal 4–20 mA
Communication HART
Transmitter Support 2-Wire and 4-Wire Devices
Configuration Redundant
Card Arrangement 2 × Analog Input Cards
Terminal Block Redundant 8-Channel Terminal Block
Application Process Measurement and HART Instrumentation
Dimensions 131 × 41.8 × 130.8 mm
Weight 0.29 kg

Product Features

  • 8-channel redundant analog input configuration for continuous process measurement.
  • Supports standard 4–20 mA process instrumentation.
  • Supports HART-enabled field transmitters.
  • Suitable for both 2-wire and 4-wire transmitter applications.
  • Uses two analog input cards in the redundant configuration.
  • Includes the associated redundant 8-channel terminal-block arrangement.
  • Integrates analog measurement data into DeltaV control and monitoring functions.
  • Suitable for process variables such as pressure, flow, level, temperature, and other continuously measured conditions.
  • Provides an input architecture suited to process applications where I/O availability is important.

Working Principle

The SE4033S2B1 receives analog current signals from field transmitters and transfers the measured process information into the DeltaV control system. HART communication can be used alongside the 4–20 mA process signal for compatible intelligent instrumentation.

Field Transmitter → Redundant Terminal Block → SE4033S2B1 Card Pair → DeltaV Controller → Control Logic / HMI / SCADA

The signal path normally operates as follows:

  • A compatible transmitter measures a process variable such as pressure, flow, temperature, or level.
  • The transmitter represents the measurement using a 4–20 mA current signal.
  • The signal enters the redundant terminal-block arrangement and is presented to the paired analog input cards.
  • The input circuitry converts the analog current into process data for the DeltaV system.
  • DeltaV control logic applies scaling, alarm limits, calculations, or control functions to the acquired value.
  • For compatible HART instruments, digital instrument information can be accessed through the HART communication path.
  • The measured process value can be displayed on operator stations or passed to supervisory applications.

The redundant architecture allows the input function to be maintained through the paired-card arrangement when an individual card fault occurs, subject to the overall DeltaV redundancy configuration.


Role in a DeltaV S-series Control Architecture

The SE4033S2B1 forms the analog measurement layer between field instrumentation and the DeltaV controller, supplying redundant process measurements for control and supervisory functions.

Process Transmitter → Redundant Terminal Block → SE4033S2B1 → DeltaV Controller → Control / Alarm / HMI / SCADA

System Element Typical Function
Process Transmitter Measures a physical process variable and generates a 4–20 mA signal
HART Instrument Provides process measurement and additional digital instrument information
Redundant Terminal Block Connects field instrumentation to the redundant AI card arrangement
SE4033S2B1 Acquires 4–20 mA signals through redundant analog input paths
DeltaV Controller Processes measurement values and executes control logic
Engineering Station Configures channels, ranges, alarms, and diagnostics
Operator Station Displays process measurements and instrument status
SCADA / Historian Provides supervisory monitoring and process data management

Industrial Applications

Application Typical Use
Oil and Gas Monitoring pressure, flow, temperature, and level transmitters
Chemical Processing Continuous acquisition of critical process variables
Power Generation Monitoring steam, water, fuel, and auxiliary process conditions
Compressor Systems Acquisition of pressure, temperature, and flow measurements
Pump Stations Monitoring suction/discharge pressure, flow, and tank level
Water Treatment Measuring flow, pressure, level, and treatment-process variables
Refining Redundant acquisition of process transmitter signals
Pharmaceutical Processing Continuous monitoring of controlled process conditions
Distributed Process Units Centralized redundant acquisition of multiple analog instruments

Installation and Maintenance

  1. Confirm that the SE4033S2B1 is the correct redundant analog input configuration for the DeltaV system.
  2. Verify that the associated redundant 8-channel terminal block is installed.
  3. Confirm the transmitter type and whether each instrument uses a 2-wire or 4-wire connection.
  4. Check that the field instrument produces a compatible 4–20 mA signal.
  5. Verify field power and transmitter loop wiring before energizing the input channels.
  6. Install the paired analog input cards according to the DeltaV S-series redundant I/O arrangement.
  7. Check terminal assignments carefully because an incorrect field connection can affect both measurement and HART communication.
  8. Keep analog instrument wiring separated from high-power switching and motor circuits where practical.
  9. Configure the input range, engineering units, scaling, and alarm limits in the DeltaV engineering environment.
  10. Compare the controller reading with the transmitter’s expected process value during commissioning.
  11. Check HART communication separately if the analog measurement is correct but digital instrument information is unavailable.
  12. If one redundant card reports a fault, inspect its seating, diagnostics, and associated connections while maintaining the healthy redundant path where possible.
  13. If several channels become abnormal simultaneously, investigate common field power, terminal connections, grounding, and redundant I/O configuration.
  14. During preventive maintenance, inspect terminal blocks, transmitter loops, card connections, and field wiring for deterioration or loose connections.

Incorrect transmitter configuration, loop wiring, field power problems, scaling errors, and HART communication issues can produce symptoms that resemble an I/O card failure. The complete signal path should be checked before replacing the module.


Related Components

Component Function
DeltaV S-series Controller Processes acquired analog values and executes control logic
Redundant 8-Channel AI Terminal Block Provides the field interface for the redundant input cards
4–20 mA Transmitters Generate continuous process measurement signals
HART Field Instruments Provide analog measurement with additional digital instrument data
24 V DC Field Supply Supplies compatible transmitter loops
S-series I/O Carrier Provides the I/O system connection
DeltaV Engineering Station Used for channel configuration and diagnostics
DeltaV Operator Station Displays process values, alarms, and instrument status
SCADA / Historian Provides supervisory monitoring and historical process data
Instrumentation Cabling Connects field transmitters to the I/O terminal arrangement

Recommended Related Models

Model / Series Product Type Typical Application
SE4033S2B1 DeltaV S-series Redundant Analog Input Card Redundant 8-channel 4–20 mA HART input
SE4003S2B1 DeltaV S-series Analog Input Card Standard 8-channel 4–20 mA HART input
SE4003S2B2 DeltaV S-series Analog Input Card 8-channel 4–20 mA HART input with fused terminal arrangement
SE4003S2B4 DeltaV S-series Analog Input Card 8-channel 4–20 mA HART input with mass I/O connection
SE4003S2B5 DeltaV S-series Analog Input Card 8-channel 4–20 mA HART input with 24-pin mass connection
SE4003S2B6 DeltaV S-series Analog Input Card 16-channel 4–20 mA HART input
SE4033S2B11 DeltaV S-series Redundant Analog Input Redundant 16-channel 4–20 mA HART applications
SE4003S6B1 DeltaV S-series RTD Input Card RTD and resistance measurement
DeltaV S-series I/O Modular I/O Platform Distributed process-control applications

Key Advantages

  • Redundant 8-channel analog acquisition supports critical process measurements.
  • Handles standard 4–20 mA signals used by a wide range of industrial transmitters.
  • HART capability supports intelligent field-instrument applications.
  • Accommodates both 2-wire and 4-wire transmitter configurations.
  • Redundant card architecture reduces dependence on a single analog input path.
  • Suitable for pressure, flow, level, temperature, and other continuous process measurements.
  • Integrates directly with the DeltaV S-series control and supervisory environment.

Technical FAQs

What type of transmitters can be connected to the SE4033S2B1?

The card is intended for compatible 4–20 mA HART transmitters, including both 2-wire and 4-wire field devices. Common applications include pressure, flow, level, and temperature transmitters.

How does HART communication relate to the 4–20 mA signal?

The 4–20 mA loop carries the primary analog process measurement, while HART adds digital communication over the same loop for compatible instruments. This allows the control system to work with the measured process value while also accessing additional instrument information.

Does the redundant configuration provide 16 independent analog inputs?

No. SE4033S2B1 is an 8-channel redundant analog input configuration using two AI cards. The duplicate card arrangement provides redundancy for the input functions rather than creating 16 independently assignable measurement channels.

What should be checked if the analog value is correct but HART communication is unavailable?

Check the transmitter’s HART capability and configuration first, followed by the loop wiring, field power, terminal connections, and DeltaV channel configuration. If the 4–20 mA measurement remains correct while HART data is unavailable, the issue may be related specifically to digital communication rather than the analog input path.



Related Products

Get the latest price? We will reply as soon as possible (within 12 hours)

No:77501