• Schneider BMXXBP0600H Modicon X80 Backplane Rack
  • Schneider BMXXBP0600H Modicon X80 Backplane Rack
  • Schneider BMXXBP0600H Modicon X80 Backplane Rack
  • Schneider BMXXBP0600H Modicon X80 Backplane Rack
Product Overview The Schneider BMXXBP0600H Modicon X80 Backplane Rack is a backplane component used to build a modular Modicon X80 I/O station. Rather than processing signals itself, the rack establishe……
Schneider BMXXBP0600H Modicon X80 Backplane Rack
  • Schneider
  • BMXXBP0600H
  • Backplane Rack
  • France
  • 103.7 × 307.6 × 19 mm
  • 0.79 kg
  • Xiamen, China
  • New & In Stock
  • T/T, PayPal, Western Union
  • 1 Year
  • 1-3 Working Days
  • DHL, UPS, TNT, FedEx and EMS.
  • 24-Hour Service
  • COO
  • 5

Our advantage

Schneider BMXXBP0600H Modicon X80 Backplane Rack

Global Logistics

We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.

Schneider BMXXBP0600H Modicon X80 Backplane Rack

Brand new and original

Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.

Schneider BMXXBP0600H Modicon X80 Backplane Rack

24-hour service

We provide 7*24 hours service to our customers. We will be there whenever you need us.

Schneider BMXXBP0600H Modicon X80 Backplane Rack

Price advantage

All our products are priced very favorably because we have our own warehouse and supply.


Company Information
E-mail [email protected]
Mobile +8615980777398
Whatsapp +8615980777398
WeChat 15980777398

Product Overview

The Schneider BMXXBP0600H Modicon X80 Backplane Rack is a backplane component used to build a modular Modicon X80 I/O station. Rather than processing signals itself, the rack establishes the physical and electrical structure in which compatible X80 modules are installed and interconnected.

In a typical X80 installation, a single controller cabinet may contain a CPU, power supply, communication interfaces, digital I/O, analog I/O, and other application-specific modules. These components need a common mounting and backplane connection arrangement. The BMXXBP0600H forms that foundation.

A practical example would be a machine-control cabinet containing several X80 I/O modules. Field sensors connect to input modules, actuators connect to output modules, and the controller exchanges data with those modules through the X80 architecture. The backplane rack holds the modules in their designated positions and establishes the internal module connection.

The BMXXBP0600H is therefore not an I/O module or controller. Its role is structural and architectural: it supports the installation and interconnection of the modules that make up an X80 station.

For maintenance work, this distinction is useful. If several modules in the same rack exhibit abnormal behavior at the same time, engineers should consider the common rack and backplane connection rather than assuming that multiple independent I/O modules have failed simultaneously.


Technical Specifications

Parameter Specification
Manufacturer Schneider Electric
Model BMXXBP0600H
Product Family Modicon X80
Product Type Backplane Rack
System Role X80 Module Mounting and Backplane Interconnection
Application Industrial Automation
Architecture Modicon X80 Modular I/O
Installation Modicon X80 Automation Station
Function Supports X80 Module Installation and Internal Bus Connection
Dimensions 103.7 × 307.6 × 19 mm
Weight 0.79 kg

Product Features

The BMXXBP0600H forms the physical foundation of a modular X80 station.

  • Schneider Electric Modicon X80 Backplane Rack
  • Model BMXXBP0600H
  • Used for X80 module installation
  • Provides the backplane connection between compatible modules
  • Supports modular PLC and I/O architectures
  • Suitable for mixed I/O and communication configurations
  • Allows multiple X80 modules to be arranged in one station
  • Useful for control cabinet construction
  • Suitable for system expansion and replacement work
  • Relevant to modular industrial automation installations

The rack should be selected according to the required number and type of X80 modules and the overall station architecture.


Working Principle

The BMXXBP0600H does not perform control calculations or field signal conversion. Its function is to give compatible X80 modules a common physical and electrical platform.

A simplified arrangement is:

Power / Controller → X80 Backplane → I/O and Communication Modules → Field Equipment

Once the applicable modules are installed, the backplane provides the internal connection required by the X80 station architecture.

For example, an X80 station may contain:

CPU / Communication Module → Backplane Rack → Digital Input → Analog Input → Digital Output

The individual modules perform their own functions, while the backplane provides the common mounting and interconnection structure.

This means the BMXXBP0600H can affect multiple modules without itself being responsible for processing their signals. If a module is not seated correctly, if the backplane connection is damaged, or if the rack has a physical problem, several modules may show abnormal behavior.

During troubleshooting, engineers should therefore look for common symptoms across neighboring modules. A single failed input channel points toward the relevant I/O module or field circuit, while several modules becoming unavailable together may justify inspection of the shared backplane infrastructure.


Role in a Modicon X80 Control Architecture

The backplane rack is positioned at the center of the local X80 module assembly.

A simplified architecture is:

PLC / Network → X80 Backplane Rack → CPU / I/O / Communication Modules → Field Devices

System Element Function
BMXXBP0600H Provides the X80 backplane and module mounting structure
X80 CPU Executes the control application
Power Supply Supplies the station’s required power
Digital Input Modules Acquire discrete field signals
Digital Output Modules Control discrete devices
Analog Input Modules Acquire analog process values
Analog Output Modules Generate analog control signals
Communication Modules Connect the station with external systems
Field Sensors Provide equipment and process information
Actuators Execute control commands

The backplane is consequently a shared infrastructure component rather than a signal-processing device.


Backplane Rack in Modular System Design

A modular PLC station allows engineers to arrange different functional modules according to the needs of the application.

For example, a process-control cabinet may require:

  • PLC processing
  • Digital input acquisition
  • Digital output control
  • Analog measurement
  • Analog control
  • Network communication

The backplane provides the physical arrangement in which these modules are installed.

This modular structure also simplifies future expansion. If an application requires additional I/O or communication functions, the engineer can evaluate whether the existing rack has sufficient capacity and whether an additional rack or related hardware is required.

The backplane therefore has a direct relationship with the physical architecture of the control cabinet.


Industrial Applications

Application Typical Use
Manufacturing Lines Centralized X80 control and I/O installation
Process Automation Modular control and signal acquisition
Packaging Machinery PLC, I/O, and communication module integration
Water Treatment Distributed or centralized X80 I/O stations
Material Handling Machine-control module assembly
Energy Systems Modular automation cabinets
Machine Building Structured PLC and I/O installation
Industrial Utilities Control and monitoring systems

The actual use depends on the X80 modules installed on the rack and the overall control-system architecture.


Installation and Maintenance

Backplane maintenance is different from servicing an I/O module because the rack can affect several installed modules at once.

Recommended practices include:

  • Confirm the complete BMXXBP0600H model.
  • Verify the required X80 rack configuration.
  • Check the number and type of modules installed.
  • Inspect the rack for physical deformation or damage.
  • Check module seating and alignment.
  • Inspect backplane connections for contamination or damage.
  • Verify that modules are correctly positioned.
  • Check the station power supply.
  • Review controller and module diagnostics.
  • Look for faults affecting multiple modules.
  • Document the existing module arrangement before replacement.
  • Follow the approved electrical isolation procedure.
  • Remove modules carefully before replacing the rack.
  • Install the replacement backplane correctly.
  • Reinstall modules in their documented positions.
  • Verify mechanical seating.
  • Restore power according to the approved procedure.
  • Check module recognition and diagnostics.
  • Confirm communication with the controller.
  • Test representative I/O points.
  • Verify the complete station under normal operating conditions.

If multiple adjacent modules become unavailable simultaneously, inspect the common backplane and station infrastructure before replacing several individual modules.


Compatible System Components

The BMXXBP0600H is normally used together with other components of a Modicon X80 station.

Component Function
BMXXBP0600H X80 backplane and module mounting
Modicon X80 CPU Control-program execution
X80 Power Supply Station power
X80 Digital Input Modules Discrete signal acquisition
X80 Digital Output Modules Discrete equipment control
X80 Analog Input Modules Analog process measurement
X80 Analog Output Modules Analog control signals
X80 Communication Modules External network communication
Terminal / Wiring Components Field signal connection
Field Devices Sensors and actuators

The exact module combination should be checked against the requirements of the X80 station.


Recommended Related Models

The recommended products below focus on Modicon X80 backplanes, I/O, power, and communication hardware that are commonly relevant when building or maintaining an X80 station.

Model / Product Family Product Type Typical Application
Schneider BMXXBP0600H Modicon X80 Backplane Rack X80 module installation and interconnection
Schneider BMXXBP0400 Modicon X80 Backplane Rack Smaller X80 module assemblies
Schneider BMXXBP0800 Modicon X80 Backplane Rack Larger X80 station configurations
Schneider BMXCPS2000 Modicon X80 Power Supply X80 station power
Schneider BMXP342020 Modicon X80 Processor PLC control applications
Schneider BMXDDI1602 Modicon X80 Digital Input Module Discrete signal acquisition
Schneider BMXDDO1602 Modicon X80 Digital Output Module Discrete output control
Schneider BMXAMI0410 Modicon X80 Analog Input Module Analog process measurement

Key Advantages

  • Schneider Electric Modicon X80 Backplane Rack.
  • Model BMXXBP0600H.
  • Provides the mounting and backplane structure for X80 modules.
  • Supports modular PLC and I/O station architectures.
  • Allows different X80 functional modules to be assembled into one station.
  • Suitable for control cabinet construction and system expansion.
  • Useful for X80 rack replacement and maintenance projects.
  • Supports organized modular automation hardware installation.

Technical FAQs

Does the BMXXBP0600H process input or output signals?

No. The BMXXBP0600H is a backplane rack rather than a signal-processing module. It provides the physical and electrical infrastructure used by compatible X80 modules installed in the station.

What symptoms can indicate a backplane-related problem?

A problem with shared backplane infrastructure can affect multiple modules at the same time. Examples may include several modules becoming unavailable, unexpected module diagnostics, or loss of communication with modules that otherwise appear physically intact.

Why is module positioning important when working with an X80 backplane?

Each X80 station has a defined hardware arrangement. Modules need to be installed in the appropriate positions and connected correctly to the backplane so that the controller can recognize and communicate with the station hardware as configured.

What should be checked before replacing the BMXXBP0600H?

Record the complete module arrangement, isolate the station according to the approved procedure, inspect the existing rack and module connections, and verify whether the fault actually affects the backplane. After installation, check module recognition, diagnostics, communication, and representative I/O operation.



Related Products

Get the latest price? We will reply as soon as possible (within 12 hours)

No:77501