• Emerson SE4002S1T2B3 DeltaV S-series Discrete Output Card
  • Emerson SE4002S1T2B3 DeltaV S-series Discrete Output Card
  • Emerson SE4002S1T2B3 DeltaV S-series Discrete Output Card
  • Emerson SE4002S1T2B3 DeltaV S-series Discrete Output Card
Product Overview The Emerson SE4002S1T2B3 DeltaV S-series Discrete Output Card is an industrial I/O module used to transmit digital control commands from the DeltaV automation system to field devices. I……
Emerson SE4002S1T2B3 DeltaV S-series Discrete Output Card
  • Emerson
  • SE4002S1T2B3
  • Discrete Output Card
  • USA
  • 131 × 41.8 × 130.8 mm
  • 0.4 kg
  • Xiamen, China
  • New & In Stock
  • T/T, PayPal, Western Union
  • 1 Year
  • 1-3 Working Days
  • DHL, UPS, TNT, FedEx and EMS.
  • 24-Hour Service
  • COO
  • 6

Our advantage

Emerson SE4002S1T2B3 DeltaV S-series Discrete Output Card

Global Logistics

We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.

Emerson SE4002S1T2B3 DeltaV S-series Discrete Output Card

Brand new and original

Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.

Emerson SE4002S1T2B3 DeltaV S-series Discrete Output Card

24-hour service

We provide 7*24 hours service to our customers. We will be there whenever you need us.

Emerson SE4002S1T2B3 DeltaV S-series Discrete Output Card

Price advantage

All our products are priced very favorably because we have our own warehouse and supply.


Company Information
E-mail [email protected]
Mobile +8615980777398
Whatsapp +8615980777398
WeChat 15980777398

Product Overview

The Emerson SE4002S1T2B3 DeltaV S-series Discrete Output Card is an industrial I/O module used to transmit digital control commands from the DeltaV automation system to field devices.

In process control applications, discrete outputs are commonly used for executing simple but critical equipment actions, such as switching relays, controlling solenoid valves, activating alarms, and operating auxiliary devices. The SE4002S1T2B3 provides the interface between DeltaV control logic and external equipment, allowing automated strategies to directly influence field operations.

As a member of the DeltaV S-series I/O platform, this output card is installed within a modular DeltaV architecture and works with controllers, carriers, terminal blocks, and engineering software. It helps organize signal communication between the control system and field layer while supporting efficient system maintenance.

For troubleshooting, engineers generally check the complete control chain, including controller logic, I/O configuration, module diagnostics, field wiring, and the connected device, rather than focusing only on the output card.


Technical Specifications

Parameter Specification
Manufacturer Emerson
Model SE4002S1T2B3
Product Family DeltaV S-series
Product Type Discrete Output Card
Main Function Digital Output Signal Control
System Role Field Device Command Interface
Dimensions 131 × 41.8 × 130.8 mm
Weight 0.4 kg

Product Features

The Emerson SE4002S1T2B3 DeltaV S-series Discrete Output Card provides digital output capability for process automation and industrial control systems.

Key characteristics include:

  • Emerson DeltaV S-series I/O module
  • Model SE4002S1T2B3
  • Designed for discrete output control applications
  • Transfers commands from DeltaV controllers to field devices
  • Supports ON/OFF control operations
  • Integrates with DeltaV modular system architecture
  • Suitable for industrial process environments
  • Simplifies connection between control logic and equipment

The module configuration should match the DeltaV database settings and connected field device requirements.


Working Principle

The SE4002S1T2B3 works by receiving digital output commands from the DeltaV controller and converting those commands into electrical signals for external devices.

The signal process is:

Control Strategy → DeltaV Controller → SE4002S1T2B3 Output Card → Terminal Connection → Field Device

When the controller determines that a device action is required, it sends a digital command to the output card. The module changes the corresponding output channel state, allowing the connected equipment to respond.

Typical operations include:

  • Energizing or de-energizing control circuits
  • Activating solenoid valves
  • Switching relays
  • Controlling discrete actuators
  • Triggering external status devices

The output card serves as the connection point between software-based automation decisions and physical equipment actions.


Role in a DeltaV Automation System

The Emerson SE4002S1T2B3 operates as the execution interface between DeltaV control logic and field equipment.

A typical system structure is:

Operator Station / Engineering Station → DeltaV Controller → Discrete Output Card → Field Device

The controller processes operating conditions and generates commands, while the output module delivers those commands to external devices.

In process industries, reliable digital output execution is essential because field equipment operation often depends on precise and timely control signals.


Industrial Applications

The Emerson SE4002S1T2B3 DeltaV S-series Discrete Output Card is commonly used in applications requiring digital equipment control.

Application Typical Use
Oil & Gas Facilities Controlling valves and auxiliary equipment
Chemical Plants Managing discrete process operations
Power Generation Executing equipment switching commands
Water Treatment Systems Operating pumps and control devices
Manufacturing Lines Controlling machine functions
Process Automation Systems Performing ON/OFF control tasks

The specific application depends on the DeltaV system design and connected field devices.


Installation and Maintenance

Proper installation and system configuration are important for reliable operation.

Recommended maintenance procedures include:

  • Confirm module model before installation
  • Verify S-series carrier compatibility
  • Check terminal wiring connections
  • Confirm output channel assignments
  • Review DeltaV I/O configuration
  • Monitor module diagnostics
  • Inspect installation environment
  • Test field device response
  • Record replacement information

When replacing an output module, engineers should verify the configuration and ensure the new card matches the original control strategy.


Related Components

The SE4002S1T2B3 is normally integrated with other DeltaV automation components.

Component Function
DeltaV Controller Executes control logic
S-series Carrier Provides module mounting and communication
Terminal Block Provides field wiring interface
Engineering Workstation Configures system parameters
Operator Station Displays process status
Field Actuators and Relays Execute output commands

These components together create a complete industrial control output system.


Recommended Related Models

Model / Product Family Product Type Typical Application
Emerson SE4002S1T2B3 DeltaV S-series Discrete Output Card Digital equipment control
Emerson SE4002S1T2B2 DeltaV S-series Discrete Output Card Field output applications
Emerson SE4002S1T1B2 DeltaV S-series Discrete Output Card Process control outputs
Emerson DeltaV S-series Digital Output Modules Digital I/O Hardware Industrial automation
Emerson DeltaV CHARMs Output Modules Modular Output Interface Flexible field connection

Model selection should be based on field device type, control requirements, and the existing DeltaV hardware configuration.


Key Advantages

  • Emerson DeltaV S-series digital output module.
  • Provides reliable field control signal transmission.
  • Supports DeltaV automation system integration.
  • Suitable for discrete equipment control.
  • Simplifies connection between controller and field devices.
  • Applied in industrial process control systems.

Technical FAQs

What role does the SE4002S1T2B3 play in a DeltaV control loop?

The module acts as the output execution point, transferring controller decisions to physical field devices.

What types of equipment can receive signals from this discrete output card?

Compatible applications include digital control devices such as relays, actuators, solenoid valves, and other ON/OFF equipment.

What should be checked if a field device does not react to an output command?

Engineers should inspect the control logic, module status, output configuration, wiring path, power supply, and field device condition.

Why is channel assignment verification necessary after module replacement?

Incorrect channel mapping can cause commands to be sent to the wrong equipment, so configuration verification is required before operation.



Related Products

Get the latest price? We will reply as soon as possible (within 12 hours)

No:77501