• Siemens 6AG1992-1AM00-7AA0 SIPLUS SFP992-1LD Plug-in Transceiver
  • Siemens 6AG1992-1AM00-7AA0 SIPLUS SFP992-1LD Plug-in Transceiver
  • Siemens 6AG1992-1AM00-7AA0 SIPLUS SFP992-1LD Plug-in Transceiver
  • Siemens 6AG1992-1AM00-7AA0 SIPLUS SFP992-1LD Plug-in Transceiver
Product Overview The Siemens 6AG1992-1AM00-7AA0 SIPLUS SFP992-1LD Plug-in Transceiver is an industrial fiber optic communication module designed for use with compatible Siemens SCALANCE X network device……
Siemens 6AG1992-1AM00-7AA0 SIPLUS SFP992-1LD Plug-in Transceiver
  • Siemens
  • 6AG1992-1AM00-7AA0
  • SIPLUS SFP992-1LD Plug-in Transceiver
  • Germany
  • 14 × 9 × 57 mm
  • 0.01 kg
  • Xiamen, China
  • New & In Stock
  • T/T, PayPal, Western Union
  • 1 Year
  • 1-3 Working Days
  • DHL, UPS, TNT, FedEx and EMS.
  • 24-Hour Service
  • COO
  • 1

Our advantage

Siemens 6AG1992-1AM00-7AA0 SIPLUS SFP992-1LD Plug-in Transceiver

Global Logistics

We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.

Siemens 6AG1992-1AM00-7AA0 SIPLUS SFP992-1LD Plug-in Transceiver

Brand new and original

Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.

Siemens 6AG1992-1AM00-7AA0 SIPLUS SFP992-1LD Plug-in Transceiver

24-hour service

We provide 7*24 hours service to our customers. We will be there whenever you need us.

Siemens 6AG1992-1AM00-7AA0 SIPLUS SFP992-1LD Plug-in Transceiver

Price advantage

All our products are priced very favorably because we have our own warehouse and supply.


Company Information
E-mail [email protected]
Mobile +8615980777398
Whatsapp +8615980777398
WeChat 15980777398

Product Overview

The Siemens 6AG1992-1AM00-7AA0 SIPLUS SFP992-1LD Plug-in Transceiver is an industrial fiber optic communication module designed for use with compatible Siemens SCALANCE X network devices. It provides a high-speed optical interface for Industrial Ethernet networks, allowing connected switches and automation equipment to exchange data over single-mode fiber optic cables.

This transceiver belongs to the Siemens SIPLUS NET product range. Compared with standard industrial networking accessories, the SIPLUS version features conformal coating and an extended operating temperature range of -40°C to +85°C. These characteristics make it suitable for industrial installations where equipment may be exposed to temperature variations and more demanding environmental conditions.

The 6AG1992-1AM00-7AA0 provides one 1000 Mbps optical LC port and supports single-mode fiber transmission over distances of up to 10 km. It operates at a nominal wavelength of 1310 nm and is intended for applications that require reliable optical communication between industrial network devices.

As a Small Form-factor Pluggable (SFP) module, the transceiver can be inserted into a compatible SFP interface without replacing the entire network switch. This modular approach allows network engineers to select optical interfaces according to the required transmission distance and fiber type.

The module is particularly relevant to industrial Ethernet infrastructure used in manufacturing facilities, distributed automation systems, process-control networks, and remote equipment connections. Before installation, users should verify that the host SCALANCE X device supports the SFP992-1LD transceiver and that the optical fiber specifications match the module.

Technical Specifications

Parameter Specification
Brand Siemens
Product Series SIPLUS NET
Model 6AG1992-1AM00-7AA0
Product Designation SFP992-1LD
Product Type Plug-in Fiber Optic Transceiver
Product Category SCALANCE X Network Accessory
Base Product 6GK5992-1AM00-8AA0
Optical Interface 1 × LC
Data Rate 1000 Mbps
Transmission Standard 1000BASE-LX
Fiber Type Single-mode optical fiber
Optical Wavelength 1310 nm
Maximum Transmission Distance Up to 10 km
Operating Temperature -40°C to +85°C
Storage Temperature -40°C to +85°C
Transport Temperature -40°C to +85°C
Conformal Coating Included
Protection Class IP20
Module Format SFP
Installation Method Plug-in / Latching
Dimensions 14 × 9 × 57 mm
Net Weight 0.01 kg
Typical Application Industrial Ethernet fiber optic communication

The maximum transmission distance depends on fiber quality, optical attenuation, connector condition, and the specifications of the connected network equipment.

Function and Working Principle

The primary function of the Siemens 6AG1992-1AM00-7AA0 is to provide an optical communication interface for compatible industrial Ethernet equipment. It converts electrical network signals from the host device into optical signals for transmission through fiber optic cable and converts received optical signals back into electrical signals.

1. Electrical-to-Optical Signal Conversion

Industrial Ethernet switches process data using electrical signals internally. When communication must travel through fiber optic cable, an optical transceiver is required.

The SFP992-1LD performs this conversion through its optical transmitter. Electrical data from the host switch is converted into light signals at the specified wavelength of 1310 nm.

At the receiving end, the optical receiver detects the incoming light signals and converts them into electrical data that the network device can process.

This conversion enables Ethernet communication over longer distances than many conventional copper connections.

2. Gigabit Ethernet Transmission

The module supports a data rate of 1000 Mbps, making it suitable for Gigabit Ethernet communication in industrial networks.

Gigabit transmission provides sufficient bandwidth for many industrial applications, including communication between network switches, PLC systems, supervisory computers, and distributed automation equipment.

The actual network throughput depends on the complete network architecture, connected equipment, and communication traffic.

3. Single-Mode Fiber Communication

The 6AG1992-1AM00-7AA0 uses single-mode optical fiber. Single-mode fiber has a small core that supports a single propagation mode, making it suitable for longer-distance optical transmission.

The module supports communication distances of up to 10 km under suitable installation conditions.

This makes it useful when network devices are installed in separate production buildings, remote control rooms, or distributed industrial facilities.

4. LC Optical Connection

The transceiver provides one LC optical interface. LC connectors are compact fiber optic connectors commonly used in industrial and commercial networking equipment.

The connector must be compatible with the installed fiber cable and the optical interface at the opposite end of the communication link.

Proper connector cleaning and careful cable handling are important because dust, scratches, and contamination can increase optical attenuation and cause communication problems.

5. Environmental Protection

The SIPLUS version includes conformal coating to provide additional protection for electronic components against certain environmental influences.

Its specified operating temperature range is -40°C to +85°C. This extended range supports applications in industrial environments where temperatures may vary considerably.

However, conformal coating does not make the module waterproof or suitable for unrestricted exposure to corrosive substances. The host network device and installation enclosure must also meet the environmental requirements of the application.

Role in Industrial Ethernet Systems

The 6AG1992-1AM00-7AA0 provides an optical connection within a wider industrial communication network. It is not a standalone Ethernet switch or controller. Instead, it works as a network interface accessory installed in a compatible SFP port.

1. Communication Between Industrial Switches

Industrial Ethernet networks often contain multiple switches distributed across production areas. Fiber optic connections allow these switches to communicate over longer distances while supporting high-speed data exchange.

The SFP992-1LD can be used to establish optical links between compatible SCALANCE X devices, provided the connected equipment supports the transceiver and the link specifications match.

2. PLC Network Communication

Programmable logic controllers exchange information with remote I/O stations, operator panels, engineering computers, and other automation devices.

The transceiver can form part of the network infrastructure connecting these devices through compatible industrial switches.

It does not perform PLC processing or control logic. Its function is to support the physical optical communication link that carries network data.

3. Distributed Automation Architecture

Large industrial facilities may distribute automation equipment across multiple production areas. Fiber optic links can connect these locations without requiring long copper Ethernet cable runs.

The 10 km maximum optical range can support communication between separated network locations when the fiber path and optical link budget are suitable.

4. Network Segmentation and Expansion

Modular SFP interfaces allow network designers to select different optical modules according to distance and fiber requirements.

The 6AG1992-1AM00-7AA0 can therefore be considered when expanding a compatible SCALANCE X network with single-mode Gigabit Ethernet connections.

Network designers should confirm the supported SFP types, port configuration, and network topology before installation.

Industrial Applications

The Siemens SIPLUS SFP992-1LD is intended for industrial network infrastructure where reliable optical communication is required.

1. Manufacturing Automation

Modern manufacturing facilities use Ethernet networks to connect PLCs, industrial switches, remote I/O stations, HMIs, and supervisory systems.

Fiber optic connections can link different production areas and support communication between network devices over longer distances.

The SFP992-1LD provides a Gigabit optical interface for compatible SCALANCE X equipment in these installations.

2. Process Control Systems

Chemical plants, water-treatment facilities, and other process industries often distribute control equipment across large areas.

Optical Ethernet connections can connect remote network cabinets and control-room infrastructure while avoiding some of the distance limitations associated with copper cabling.

The extended temperature range of the SIPLUS module can also be relevant to installations exposed to demanding ambient conditions.

3. Power Generation and Energy Facilities

Power generation and energy distribution facilities may use industrial Ethernet networks for monitoring, supervisory communication, and equipment coordination.

Fiber optic links can connect network devices installed in separate buildings or equipment areas.

The module can support these links when the network equipment and optical design meet the required specifications.

4. Transportation and Infrastructure

Transportation infrastructure frequently relies on distributed communication networks for monitoring, equipment management, and control-system connectivity.

Single-mode fiber is useful where communication links must cover relatively long distances between network cabinets.

The SFP992-1LD can be used in compatible network equipment to provide a 1000 Mbps optical connection.

5. Remote Industrial Network Connections

Some industrial sites have network devices installed in remote equipment rooms, substations, pumping stations, or separate production buildings.

Using single-mode fiber can help establish communication links between these locations without depending on long copper Ethernet runs.

The maximum supported distance of up to 10 km provides flexibility for appropriately designed optical network connections.

Installation and System Integration

Correct installation is essential for maintaining optical signal quality and stable network communication.

1. Verify Host Device Compatibility

Before installing the transceiver, confirm that the host Siemens SCALANCE X device supports the SFP992-1LD or its corresponding approved module configuration.

Check the switch documentation for supported transceiver types, port requirements, and firmware compatibility.

A physically compatible SFP slot does not necessarily guarantee that every transceiver model is supported.

2. Inspect the Optical Fiber

The module is designed for single-mode fiber communication. Verify that the installed cable is suitable for the 1310 nm optical wavelength and the required transmission distance.

Check the fiber type, connector termination, cable condition, and optical attenuation before connecting the module.

Using an incompatible fiber type may result in poor signal quality or communication failure.

3. Install the SFP Module

Before installation, follow the safety and handling instructions for the host switch and optical transceiver.

Align the module with the SFP slot and insert it carefully until the retaining mechanism engages.

Avoid applying excessive force. If the module does not fit correctly, inspect the slot and module orientation instead of forcing the connection.

4. Connect the LC Fiber Cable

Remove protective dust caps only when the optical connectors are ready to be connected.

Inspect and clean the LC connectors using suitable fiber optic cleaning equipment. Connect the fiber carefully and ensure that the connector is fully seated.

Keep unused optical ports protected with appropriate dust caps.

Never look directly into an active optical port or fiber connector.

5. Verify Optical Link Status

After installation, check the host switch’s port indicators and diagnostic information.

Confirm that the optical link is established and that the connected network devices can exchange data.

If the link does not come online, check:

  • SFP module compatibility.
  • Fiber type and optical wavelength.
  • LC connector condition.
  • Transmit and receive fiber polarity.
  • Optical attenuation and cable damage.
  • Configuration and status of the connected switch port.

6. Maintain Environmental Conditions

The module supports an operating temperature range of -40°C to +85°C, with the manufacturer’s qualification that the maximum +85°C operating temperature is permitted for up to 16 hours.

Although the module has conformal coating, it is important to maintain suitable environmental conditions around the host switch.

Avoid direct exposure to water, conductive contamination, and mechanical damage. Ensure that the switch enclosure provides appropriate protection for the complete installation.

Compatible System Components

The 6AG1992-1AM00-7AA0 is used as part of a larger industrial Ethernet infrastructure.

Component Function Integration Considerations
Siemens SCALANCE X Industrial Ethernet Switch Provides network switching and SFP interface Verify support for the SFP992-1LD
Siemens 6GK5992-1AM00-8AA0 Related standard SFP992-1LD transceiver Check environmental and ordering-code differences
Single-Mode Fiber Optic Cable Carries optical Ethernet signals Must support the required wavelength and distance
LC Fiber Optic Connector Provides optical cable termination Connector type and cleanliness are important
Industrial Ethernet Switch Connects network devices Verify Gigabit optical port compatibility
PLC System Executes automation and process-control logic Communicates through the industrial Ethernet network
HMI Panel Displays process information and operator commands Connect through the network architecture
Engineering Workstation Supports configuration and diagnostics Requires a suitable network connection
Fiber Optic Patch Panel Organizes and distributes fiber connections Ensure correct fiber type and connector arrangement

These components are examples of equipment that may be used in a complete network installation. They are not necessarily included with the transceiver.

Alternative Models and Replacement Considerations

When replacing or expanding an industrial optical network, the alternative transceiver must match the host device, optical fiber, transmission distance, and required data rate.

Alternative Model Main Characteristics Selection Considerations
Siemens 6GK5992-1AM00-8AA0 Standard SFP992-1LD, 1 Gbps single-mode LC, up to 10 km Related base product; environmental specifications differ
Siemens 6AG1992-1AL00-7AA0 SIPLUS SFP992-1, 1 Gbps multimode LC Designed for multimode fiber and shorter distances
Siemens 6AG1991-1AF00-7AA0 SIPLUS SFP991-1LD, 100 Mbps single-mode LC Lower data rate with a different transmission-distance specification
Siemens 6GK5992-1AL00-8AA0 Standard SFP992-1, 1 Gbps multimode LC Requires compatible multimode fiber
Siemens 6GK5992-1AN00-8AA0 SFP992-1LH, long-haul optical transceiver Different optical performance and distance requirements

A replacement should not be selected based only on the physical SFP form factor. Check the following parameters:

  • Supported data rate.
  • Single-mode or multimode fiber type.
  • Optical wavelength.
  • LC connector compatibility.
  • Maximum transmission distance.
  • Optical transmitter and receiver specifications.
  • Host switch compatibility.
  • Operating temperature range.
  • Conformal coating requirements.

The standard 6GK5992-1AM00-8AA0 is the related base product for this SIPLUS version, but the environmental specifications should be considered before substituting one for the other.

Key Advantages

Gigabit Optical Communication

The SFP992-1LD supports a 1000 Mbps optical connection, making it suitable for Gigabit Ethernet links in industrial network infrastructure.

Single-Mode Transmission up to 10 km

Its single-mode optical interface supports communication distances of up to 10 km under suitable fiber and link conditions.

Compact SFP Design

The compact plug-in format allows the module to be installed in compatible network equipment without requiring a separate external transceiver enclosure.

Extended Temperature Capability

The specified operating range of -40°C to +85°C supports use in industrial installations with demanding ambient temperature conditions.

Conformal Coating

The SIPLUS version includes conformal coating to provide additional protection for electronic components in suitable industrial environments.

Flexible Network Expansion

The optical interface allows compatible SCALANCE X network devices to be connected through single-mode fiber, supporting distributed network architectures.

Low Weight and Compact Dimensions

With dimensions of 14 × 9 × 57 mm and a net weight of 0.01 kg, the transceiver occupies very little installation space.

Technical FAQs

1. What is the Siemens 6AG1992-1AM00-7AA0?

It is a SIPLUS NET SCALANCE X SFP992-1LD plug-in fiber optic transceiver designed for compatible Siemens industrial Ethernet equipment.

2. What is the data transmission speed?

The module supports a data rate of 1000 Mbps, making it suitable for Gigabit Ethernet communication.

3. What type of fiber optic cable does it use?

It uses single-mode optical fiber. The connected cable and optical connectors must match the module’s interface specifications.

4. What is the maximum transmission distance?

The specified maximum optical transmission distance is up to 10 km. Actual performance depends on the fiber quality, optical attenuation, connectors, and the connected equipment.

5. What is the operating wavelength?

The module operates at a wavelength of 1310 nm.

6. What connector does the transceiver use?

It provides one LC optical port. The fiber cable must use a compatible LC connector arrangement.

7. What is the operating temperature range?

The specified operating temperature range is -40°C to +85°C. The manufacturer notes that operation at the maximum +85°C temperature is permitted for a duration of up to 16 hours.

8. What is the difference between the SIPLUS version and the standard version?

The 6AG1992-1AM00-7AA0 is based on the standard 6GK5992-1AM00-8AA0 and includes conformal coating with an extended temperature specification. The two ordering numbers should not be treated as environmentally identical.

9. Can this transceiver be installed in any SFP slot?

No. The host network device must support the SFP992-1LD or an approved compatible transceiver. Check the switch documentation before installation.

10. What should be checked if the optical link does not work?

Check the host device’s SFP compatibility, fiber type, LC connector condition, fiber polarity, optical attenuation, and port configuration. Also verify that the connected transceiver at the opposite end has compatible optical specifications.

Procurement and Maintenance Recommendations

When purchasing the Siemens 6AG1992-1AM00-7AA0, verify the complete ordering number and confirm that the supplied module is the SIPLUS SFP992-1LD version rather than a standard or multimode SFP product.

For industrial replacement projects, check the host SCALANCE X switch model and confirm that it supports this transceiver. Pay particular attention to the optical interface, data rate, wavelength, fiber type, and maximum transmission distance.

If the equipment operates in a demanding environment, confirm that the SIPLUS temperature specification and conformal coating requirements are appropriate for the installation. Do not assume that every SFP module with a similar appearance provides the same environmental protection.

During maintenance, inspect the LC connectors and fiber cables for contamination, damage, or excessive bending. Keep unused optical interfaces protected with dust caps. Use suitable fiber optic cleaning tools and verify link status after reconnection.

For critical industrial networks, maintain records of installed transceiver models, fiber routes, optical link parameters, and switch port assignments. Keeping compatible spare modules available can also reduce recovery time when an optical communication fault occurs.

Conclusion

The Siemens 6AG1992-1AM00-7AA0 SIPLUS SFP992-1LD Plug-in Transceiver is a compact industrial fiber optic communication module designed for compatible SCALANCE X networking equipment. It provides one 1000 Mbps LC optical port, uses 1310 nm single-mode fiber, and supports transmission distances of up to 10 km.

Its conformal coating and extended operating temperature range of -40°C to +85°C make it suitable for selected industrial environments where standard networking accessories may not meet environmental requirements.

For industrial Ethernet installation, maintenance, and network expansion, the 6AG1992-1AM00-7AA0 offers a modular optical interface for connecting compatible network devices through single-mode fiber optic links.



Related Products

Get the latest price? We will reply as soon as possible (within 12 hours)

No:77501