Our advantage
Global Logistics
We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.
Brand new and original
Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.
24-hour service
We provide 7*24 hours service to our customers. We will be there whenever you need us.
Price advantage
All our products are priced very favorably because we have our own warehouse and supply.
| Company Information | |||
| [email protected] | |||
| Mobile | +8615980777398 | ||
| +8615980777398 | |||
| 15980777398 |

The Siemens 6AG1134-4GB52-2AB0 Analog Input Module is an industrial analog input module designed for accurate acquisition of analog process signals in PLC-based automation systems. As part of the SIPLUS ET 200S distributed I/O family, the module provides reliable analog signal conversion for demanding industrial environments where continuous process monitoring and stable data acquisition are essential.
The module receives analog signals from field devices such as pressure transmitters, temperature transmitters, flow meters, level sensors, position transmitters, and other industrial instruments. These analog values are converted into digital data and transmitted to the PLC CPU for real-time monitoring, control, and process optimization.
The supplied product information identifies the Siemens 6AG1134-4GB52-2AB0 as an Analog Input Module, with dimensions of 15 × 81 × 52 mm and a weight of 0.04 kg.
| Parameter | Specification |
|---|---|
| Manufacturer | Siemens |
| Model Number | 6AG1134-4GB52-2AB0 |
| Product Type | Analog Input Module |
| Dimensions | 15 × 81 × 52 mm |
| Weight | 0.04 kg |
| Installation | ET 200S Distributed I/O |
| Signal Type | Analog Input |
| Mounting | Industrial Control Cabinet |
| Primary Function | Analog Data Acquisition |
| Maintenance | Inspection and Troubleshooting |
The dimensions and weight shown above are based on the supplied product information.
The Siemens 6AG1134-4GB52-2AB0 continuously receives analog signals generated by industrial field devices and converts them into digital values that are processed by the PLC.
Typical signal flow:
Field Sensor
↓
Analog Signal
↓
6AG1134-4GB52-2AB0
↓
PLC CPU
↓
Control Program
↓
Industrial Equipment
Typical connected devices include:
The module continuously samples and converts analog measurements, allowing the PLC to monitor and control industrial processes accurately.
Collects continuous analog process data from industrial instruments.
Acquires pressure, flow, and temperature measurements.
Monitors pumps, pipelines, reservoirs, and treatment systems.
Supports process measurement throughout production and transportation facilities.
Provides accurate process measurements for automated production.
Acquires analog operating data from auxiliary systems.
Supports production equipment requiring continuous analog monitoring.
Confirm the complete product identification:
Always verify the model number before installation.
Inspect the module for:
Do not install a damaged module.
Verify:
Module dimensions:
15 × 81 × 52 mm
Weight:
0.04 kg
Install the module securely within the ET 200S distributed I/O station.
Verify:
Separate analog signal cables from high-power electrical wiring whenever possible.
Confirm:
Ensure configuration matches the connected instrumentation.
Before energizing the system verify:
Confirm that the module starts normally without diagnostic alarms.
Possible causes:
Recommended actions:
Possible causes:
Inspect the complete signal path.
Possible causes:
Inspect shielding and grounding.
Possible causes:
Compare PLC readings with calibrated test equipment.
Possible causes:
Review PLC diagnostics before replacing hardware.
Possible causes:
Inspect all connections thoroughly.
Possible causes:
Keep analog cables isolated from power cables.
Possible causes:
Test each channel individually.
Possible causes:
Ensure sufficient airflow around the module.
Possible causes:
Verify communication between the PLC and ET 200S station.
Recommended troubleshooting sequence:
Power Supply
↓
PLC Hardware Configuration
↓
Module Status
↓
Field Wiring
↓
Sensor
↓
Signal Verification
↓
System Operation
Following this sequence helps isolate hardware, wiring, and configuration problems efficiently.
| Maintenance Item | Recommended Action |
|---|---|
| Module Housing | Inspect regularly |
| Connectors | Check for secure connection |
| Wiring | Inspect for damage |
| Grounding | Verify continuity |
| PLC Diagnostics | Review periodically |
| Cabinet | Keep clean and dry |
| Ventilation | Maintain adequate airflow |
| Signal Quality | Verify regularly |
| Mounting | Check mechanical security |
| Maintenance Records | Update after service |
Maintain suitable cabinet temperatures for reliable operation.
Clean excessive dust accumulation during scheduled maintenance.
Prevent condensation and water ingress.
Inspect connectors periodically where vibration exists.
Use proper shielding and cable routing practices to minimize electrical noise.
It is an industrial Analog Input Module designed for acquiring analog process signals within Siemens ET 200S distributed I/O automation systems.
The module receives analog signals from field devices and converts them into digital process data for PLC processing.
The supplied dimensions are 15 × 81 × 52 mm.
The supplied weight is 0.04 kg.
Possible causes include installation errors, configuration problems, connector faults, power supply issues, or module failure.
Electrical interference, poor grounding, loose wiring, sensor faults, or improper cable routing are common causes.
Inspect the field transmitter, wiring, PLC configuration, terminal assignments, and signal continuity.
It is commonly used in process automation, water treatment, chemical plants, oil and gas, manufacturing, food processing, and power generation.
Inspect connectors, wiring, grounding, cabinet cleanliness, ventilation, and PLC diagnostics on a regular maintenance schedule.
Replace the module if persistent hardware faults remain after troubleshooting or if reliable analog signal acquisition cannot be restored.
The Siemens 6AG1134-4GB52-2AB0 Analog Input Module provides dependable analog signal acquisition for Siemens ET 200S distributed I/O systems. Its compact 15 × 81 × 52 mm dimensions and lightweight 0.04 kg design make it ideal for high-density industrial control cabinets while ensuring stable and accurate process data collection.
Proper installation, correct PLC configuration, reliable grounding, and careful wiring practices are essential for achieving optimum performance. Through systematic commissioning, preventive maintenance, and structured fault diagnosis, the Siemens 6AG1134-4GB52-2AB0 can deliver long-term reliability and consistent operation in demanding industrial automation applications.