1. Product Overview The Schneider TSXMRP0128P SRAM Application Memory Expansion is an industrial automation memory component intended for compatible Schneider Electric programmable logic controller (PLC……
Schneider TSXMRP0128P SRAM Application Memory Expansion
  • Schneider
  • TSXMRP0128P
  • SRAM Application Memory Expansion
  • France
  • 132 x 91 x 26 mm
  • 0.076 kg
  • Xiamen, China
  • New & In Stock
  • T/T, PayPal, Western Union
  • 1 Year
  • 1-3 Working Days
  • DHL, UPS, TNT, FedEx and EMS.
  • 24-Hour Service
  • COO
  • 3

Our advantage

Schneider TSXMRP0128P SRAM Application Memory Expansion

Global Logistics

We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.

Schneider TSXMRP0128P SRAM Application Memory Expansion

Brand new and original

Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.

Schneider TSXMRP0128P SRAM Application Memory Expansion

24-hour service

We provide 7*24 hours service to our customers. We will be there whenever you need us.

Schneider TSXMRP0128P SRAM Application Memory Expansion

Price advantage

All our products are priced very favorably because we have our own warehouse and supply.


Company Information
E-mail [email protected]
Mobile +8615980777398
Whatsapp +8615980777398
WeChat 15980777398

1. Product Overview

The Schneider TSXMRP0128P SRAM Application Memory Expansion is an industrial automation memory component intended for compatible Schneider Electric programmable logic controller (PLC) systems. SRAM-based memory components are used in automation architectures to provide storage for application data and other controller-related information, depending on the supported hardware configuration.

In industrial control systems, application memory is essential for storing the program information and data required for machine sequencing, process monitoring, and automated equipment coordination. Selecting the correct memory expansion helps ensure that the controller’s memory configuration matches the requirements of the installed application.

Static Random Access Memory (SRAM) provides fast data access and is commonly used where a controller requires working memory or application storage. Unlike non-volatile Flash EPROM, conventional SRAM generally requires continuous power to retain its contents unless supported by a battery-backed or other retention arrangement. The specific retention method and supported functions of the TSXMRP0128P should therefore be verified against the applicable controller documentation.

For maintenance engineers and industrial spare-parts buyers, confirming the exact PLC model, memory interface, hardware revision, and application requirements is essential before ordering or installing this component.

2. Technical Specifications

Parameter Specification
Brand Schneider Electric
Model Number TSXMRP0128P
Product Type SRAM Application Memory Expansion
Memory Technology Static Random Access Memory (SRAM)
Primary Function Application memory expansion
Dimensions 132 × 91 × 26 mm
Weight 0.076 kg
Product Category PLC Memory Component
Typical Application Compatible industrial automation and PLC systems
Installation Method Depends on the supported controller and memory interface
Compatibility Must be verified against the target PLC model
Data Retention Method Confirm from the applicable product and controller documentation

Specification note: The dimensions and weight are based on the supplied product information. The exact memory capacity, supported PLC references, battery or retention requirements, and programming procedures should be confirmed before installation or replacement.

3. Function and Working Principle

The TSXMRP0128P is identified as an SRAM application memory expansion. Its precise function depends on the PLC platform for which it was designed and the memory architecture supported by that controller.

3.1 Application Memory Storage

A PLC executes a control program that determines how machinery and processes respond to sensor inputs, operator commands, and internal operating conditions. The controller’s memory architecture provides storage for the information required to execute and manage the application.

A compatible memory expansion can provide additional storage resources or support a designated memory function within the controller. The exact role of the TSXMRP0128P should be confirmed for the intended hardware configuration.

3.2 SRAM Technology

Static Random Access Memory stores data electronically and allows rapid access to individual memory locations. It is commonly used in computing and control systems where fast read and write operations are required.

Conventional SRAM is volatile, meaning that it normally loses its stored contents when its power supply is removed. Some industrial memory designs use a battery-backed or other retention mechanism to preserve data. The retention arrangement used by the TSXMRP0128P must be verified rather than assumed.

3.3 Interaction with the PLC

When installed in a supported controller, an application memory component works as part of the overall PLC memory architecture. The controller accesses memory according to its hardware design and firmware capabilities.

Compatibility involves more than matching the memory technology. The physical interface, supported capacity, memory organization, controller firmware, and intended application function must all be considered.

3.4 Application Data Management

Memory-related maintenance may involve preserving application information, checking the memory configuration, or restoring data after a component replacement. The appropriate procedure depends on the controller and the specific memory design.

Before replacing or removing the component, engineers should determine whether it contains application data that must be preserved and whether a backup or retention procedure is required.

4. Role in Industrial Automation Systems

Memory components form part of the hardware foundation of PLC-based automation systems. They support the storage and management functions required by the controller, although the exact role of each memory module varies by platform.

Control Program Support

PLC applications define machine sequences, interlocks, operating modes, and process responses. The correct memory configuration helps provide the resources required by the controller’s intended application.

Fast Memory Access

SRAM technology is known for fast access to stored data. Where supported by the controller architecture, SRAM memory can serve functions that require efficient read and write operations.

Maintenance and Replacement

When a memory component develops a fault or needs replacement, identifying the correct model helps prevent incompatible installations. Technicians should also establish whether the original application data must be preserved before removing the existing component.

Legacy Automation Support

Industrial facilities often maintain established PLC systems for many years. Correctly identified spare memory components can support repair planning and help reduce the need for unnecessary changes to a working control system.

Application Recovery

If the component stores information that is not automatically preserved elsewhere, replacing it without a verified backup could result in data loss. Maintenance teams should follow the documented recovery procedure for the specific controller.

5. Industrial Applications

The TSXMRP0128P is intended for compatible PLC configurations. The following examples describe common environments in which PLC memory components are used; they do not establish compatibility with every application listed.

Manufacturing and Assembly Equipment

Manufacturing lines use PLCs to coordinate motors, sensors, actuators, and machine sequences. Appropriate memory configuration supports the control application used to manage these operations.

Packaging Machinery

Packaging equipment relies on programmed sequences for product positioning, filling, sealing, labeling, and material transfer. Suitable controller memory supports the storage and execution requirements of the automation application.

Material Handling Systems

Conveyor and transfer systems use PLC logic to coordinate movement, equipment status, and sequencing. Memory components may form part of the controller configuration required for these tasks.

Process Automation

Industrial process systems use programmable controllers to manage operating sequences, equipment states, and process interlocks. The correct memory configuration helps support the required control functions.

Maintenance of Existing PLC Installations

The TSXMRP0128P may be relevant when maintaining a compatible Schneider Electric PLC installation. Before purchasing, confirm the exact controller reference and the supported memory expansion options.

6. Installation and System Integration

Correct installation begins with confirming the exact part number and the requirements of the target controller. Memory components should not be installed based solely on physical fit or a similar product description.

Step 1: Verify the Product Reference

Check that the component label identifies the model as TSXMRP0128P. Compare the reference with the existing component, equipment bill of materials, and approved spare-parts documentation.

Step 2: Confirm Controller Compatibility

Identify the exact PLC model, processor reference, hardware revision, and relevant firmware version. Verify that the controller supports the TSXMRP0128P and the intended memory function.

Step 3: Protect Existing Application Data

Before removing the original memory component, determine whether it contains application data or configuration information that must be retained.

Create and verify a suitable backup using the controller’s supported procedures. If the memory design includes a battery or another retention mechanism, confirm its requirements before performing maintenance.

Step 4: Isolate the Equipment

Place the machinery in a safe state and isolate the relevant power sources according to the site’s lockout/tagout procedure. Follow the manufacturer’s instructions regarding powered or unpowered memory replacement.

Do not assume that the component supports hot swapping or that removing it while energized is safe.

Step 5: Apply ESD Precautions

Use suitable electrostatic discharge protection when handling the component. Avoid touching exposed contacts, and keep the module in appropriate protective packaging when it is not installed.

Step 6: Install According to the Approved Procedure

Use the specified mounting method and orientation for the target controller. Ensure that the component is correctly seated and that no connector or housing damage occurs during installation.

Step 7: Verify the Memory Configuration

Restore power according to the approved commissioning procedure. Check controller status indicators, diagnostic messages, and the memory configuration using the supported engineering tools.

Step 8: Validate System Operation

Confirm that the expected application is available and that the controller operates correctly. Perform controlled functional tests before returning the equipment to normal service.

7. Common Problems and Troubleshooting

Memory-related faults can originate from an incompatible component, an installation problem, data-retention issues, or a fault elsewhere in the controller system.

Symptom Possible Cause Recommended Action
Memory component is not recognized Incorrect model or installation problem Verify the complete part number, interface, and installation procedure
PLC application fails to start Missing or incompatible application data Review controller diagnostics and confirm the application version
Stored information is lost after power removal Volatile memory or retention mechanism issue Check the documented retention method and applicable battery requirements
Memory-related diagnostic appears Unsupported configuration or hardware fault Record the diagnostic code and consult the relevant controller documentation
Machine behavior changes after replacement Incorrect application or configuration Compare the installed application with a verified backup
Programming or data transfer fails Unsupported tool or procedure Confirm the required software, programming method, and controller support
Fault persists after replacement Cause may be external to the memory component Check controller compatibility, power, connections, firmware, and related hardware

7.1 Check Model Compatibility

Verify that the installed memory component is supported by the exact PLC model. Similar physical dimensions or memory technology do not guarantee compatibility.

7.2 Review Data Retention

If stored information disappears following a shutdown or power interruption, determine whether the memory is volatile and whether a battery-backed or other retention arrangement is required. Follow the specific controller’s diagnostic and maintenance procedures.

7.3 Check Application Integrity

If the controller cannot start the expected program, compare the installed application with the approved backup. Confirm that the program is compatible with the controller and that any required transfer or initialization procedure has been completed.

7.4 Inspect Connections and Installation

With the equipment in a safe state, inspect the relevant connectors and mounting arrangement. Look for visible damage, contamination, or incorrect seating.

7.5 Use Diagnostic Information

Record controller error codes and status indications before changing settings or replacing additional components. This helps distinguish memory faults from broader processor, power, or configuration problems.

8. Preventive Maintenance

Preventive maintenance can help protect memory components and reduce the risk of avoidable application recovery problems.

  • Maintain verified backups: Keep current copies of PLC applications and relevant configuration data where supported.
  • Document memory configuration: Record the exact component model and its role in the installed controller.
  • Check retention requirements: If the system uses a battery-backed memory arrangement, follow the specified inspection and replacement schedule.
  • Apply ESD precautions: Use appropriate protective procedures when handling electronic components.
  • Store spare parts correctly: Keep unused modules in suitable protective packaging and within the specified storage environment.
  • Monitor controller diagnostics: Investigate recurring memory-related warnings instead of repeatedly resetting them.
  • Document hardware changes: Record replacement dates, model numbers, application versions, and commissioning results.
  • Follow approved procedures: Use the manufacturer’s instructions and site safety rules for all maintenance activities.

Maintenance intervals and retention procedures depend on the actual hardware design and the operating environment.

9. Compatibility and Replacement Considerations

Selecting a replacement for the TSXMRP0128P requires verification of the controller’s hardware and application requirements.

Exact Model Number

Confirm the complete reference TSXMRP0128P. Memory components with similar model numbers may have different interfaces, capacities, retention characteristics, or supported PLC families.

PLC Family and Hardware Revision

Check the target PLC and processor references. Compatibility with one controller does not establish compatibility with every Schneider Electric automation platform.

Memory Capacity and Organization

Confirm that the replacement supports the memory capacity and organization required by the application. The exact capacity and supported functions should be established from the relevant product documentation.

Data Retention Requirements

Determine whether the memory design is volatile and whether the system uses a battery or another retention method. Confirm any required backup or maintenance procedures before removing the existing component.

Programming and Firmware Support

Verify the controller’s firmware requirements and the tools used to configure or transfer application data. Some legacy systems may have specific software or hardware dependencies.

Application Recovery

Before replacing the component, confirm whether the application is stored elsewhere or must be restored from a backup. Do not assume a replacement module arrives with the required program.

Replacement recommendation: Select a replacement only after confirming its functional equivalence, memory interface, retention requirements, and compatibility with the exact PLC configuration.

10. Key Benefits

When correctly matched to a supported controller, the TSXMRP0128P may provide the following benefits:

  • Application memory support: Contributes to the memory configuration required by a compatible PLC application.
  • SRAM technology: Provides the fast memory access associated with Static Random Access Memory.
  • Support for established automation systems: May help maintain compatible installed PLC equipment.
  • Improved spare-part control: Accurate model identification helps reduce purchasing and replacement errors.
  • Structured application recovery: Correct backup and retention procedures help protect important control data.
  • Maintenance planning: Documented compatibility and configuration requirements support more organized service activities.

The actual benefits depend on the component’s verified function and the requirements of the target controller.

11. Frequently Asked Questions

Q1: What is the Schneider TSXMRP0128P?

The Schneider TSXMRP0128P is identified as an SRAM Application Memory Expansion for compatible industrial PLC configurations.

Q2: What does SRAM mean?

SRAM stands for Static Random Access Memory. It is a semiconductor memory technology known for fast data access. Conventional SRAM is volatile and generally requires continuous power to retain its contents.

Q3: What are the dimensions and weight of the TSXMRP0128P?

The supplied specifications list dimensions of 132 × 91 × 26 mm and a weight of 0.076 kg.

Q4: Does SRAM retain data when power is removed?

Conventional SRAM does not retain data without power. Some industrial memory designs use battery-backed or other retention arrangements. The specific retention method of the TSXMRP0128P must be verified before maintenance.

Q5: Is the TSXMRP0128P compatible with all Schneider Electric PLCs?

No. Compatibility depends on the specific PLC family, processor, hardware revision, memory interface, and supported configuration.

Q6: Can the TSXMRP0128P replace a Flash EPROM memory expansion?

Not automatically. SRAM and Flash EPROM use different memory technologies and may serve different functions. A substitution is appropriate only if the controller documentation explicitly supports the proposed replacement.

Q7: What should be checked before replacing the memory component?

Confirm the complete part number, controller compatibility, application backup, memory retention method, and approved installation procedure. Check whether removing the component could result in data loss.

Q8: What should be done if the PLC reports a memory fault?

Record the diagnostic information, verify the installed component, inspect the approved configuration, and check the application’s integrity. Follow the controller-specific troubleshooting procedure before replacing additional hardware.

Q9: Does the TSXMRP0128P include a preloaded PLC application?

The presence of a particular application should not be assumed. Confirm the supplied component’s condition and contents, and ensure that the required application can be restored using an approved procedure.

12. Conclusion

The Schneider TSXMRP0128P SRAM Application Memory Expansion is an industrial automation memory component intended for compatible PLC systems. SRAM technology is associated with fast data access, while the exact memory function and data-retention arrangement depend on the supported hardware design.

For maintenance engineers, system integrators, and industrial spare-parts buyers, correct identification is essential. Before installation or replacement, verify the PLC model, memory interface, application requirements, and data-retention procedure. Maintaining reliable backups and following approved handling instructions can help reduce the risk of application loss and unnecessary downtime.

The supplied dimensions are 132 × 91 × 26 mm, and the listed weight is 0.076 kg. Confirming these specifications alongside the target controller’s compatibility requirements supports more accurate spare-parts selection and reliable maintenance planning.



Related Products

Get the latest price? We will reply as soon as possible (within 12 hours)

No:77501