The Schneider ATS22C25S6 Soft Starter for Asynchronous Motor belongs to the Altistart 22 family and is used to manage the starting and stopping process of asynchronous motors in industrial equipment.
In practical motor-control applications, direct starting can cause a sudden increase in current and a sharp torque response. This can be undesirable on equipment with belts, couplings, pumps, compressors, conveyors, or other mechanical transmission components. The ATS22C25S6 controls the motor during the starting phase, allowing the machine to reach operating conditions more progressively.
The unit is particularly suitable for installations where the main requirement is controlled motor starting and stopping, rather than continuous adjustment of motor speed. It can therefore be considered for general industrial machinery, pumping systems, fans, compressors, and material-handling equipment.
| Parameter | Details |
|---|---|
| Manufacturer | Schneider Electric |
| Model | ATS22C25S6 |
| Product Type | Soft Starter |
| Series | Altistart 22 |
| Motor Type | Asynchronous Motor |
| Main Function | Motor Starting and Stopping Control |
| Control Method | Soft Start / Soft Stop |
| System Role | Motor Starter / Controller |
| Application | Industrial Motor Control |
| Typical Use | Pumps, Fans, Compressors, Conveyors and Machinery |
| Dimensions | 425 × 206 × 299 mm |
| Weight | 33 kg |
The ATS22C25S6 is intended for applications where the motor needs a controlled transition into and out of operation.
The final starter selection should take into account the motor characteristics, electrical supply, starting conditions, and driven load.
The ATS22C25S6 is connected between the electrical supply and the asynchronous motor. During startup, it controls the electrical conditions applied to the motor instead of allowing the motor to transition directly from zero speed to full supply conditions.
A simplified arrangement is:
Incoming Power → ATS22C25S6 → Asynchronous Motor → Mechanical Load
This controlled acceleration is useful when a sudden torque increase could place unnecessary stress on a mechanical transmission. On a conveyor, for example, it can help avoid an abrupt belt acceleration. On a pump system, a controlled transition can also be preferable to an instantaneous motor start.
The same principle can be applied during stopping when the application requires a more controlled reduction in motor operation.
The ATS22C25S6 is therefore primarily a starting and stopping controller, not a device intended for continuous variable-speed operation.
The ATS22C25S6 can be used in a range of industrial motor applications where controlled starting is required.
| Application | Typical Use |
|---|---|
| Pump Systems | Controlled motor startup and stopping |
| Fans | Smooth acceleration of fan motors |
| Compressors | Controlled starting under load |
| Conveyor Systems | Reduced starting impact on belts |
| Material Handling | Controlled motor acceleration |
| HVAC Equipment | Motor starting control |
| Process Machinery | Asynchronous motor soft starting |
| General Industrial Equipment | Start/stop control |
The suitability of the starter depends on the characteristics of both the motor and the connected mechanical load.
The ATS22C25S6 normally works as part of a complete motor-control installation.
| Component | Function |
|---|---|
| ATS22C25S6 | Controls motor starting and stopping |
| Asynchronous Motor | Converts electrical power into mechanical rotation |
| Circuit Protection | Protects the incoming electrical circuit |
| Motor Protection Device | Provides motor protection |
| Main Contactor | Switching and electrical isolation |
| Control System | Sends start and stop commands |
| Motor Cable | Connects the starter to the motor |
| Mechanical Load | Receives the motor’s mechanical output |
The starter should be evaluated together with the motor, protection equipment, control circuit, and mechanical load when planning a replacement or new installation.
The ATS22C25S6 is intended for installation within an appropriate electrical cabinet or control enclosure. Its relatively large physical size and 33 kg weight should be considered when planning cabinet mounting and mechanical support.
Before installation or replacement, technicians should verify the complete model number and application requirements.
Recommended checks include:
If the motor does not start correctly, the investigation should include the motor, wiring, load, protection devices, control signals, and starter configuration rather than assuming the starter itself is defective.
Related Altistart 22 models can be considered according to motor requirements and application conditions.
| Model / Component | Type | Primary Function | Application |
|---|---|---|---|
| Schneider ATS22C25S6 | Altistart 22 Soft Starter | Motor starting and stopping | Industrial motor control |
| Schneider ATS22C25Q | Altistart 22 Digital Soft Starter | Controlled motor starting | Industrial machinery |
| Schneider ATS22C14S6U | Altistart 22 Soft Starter | Asynchronous motor control | Motor starting applications |
| Schneider ATS22C14S6 | Altistart 22 Soft Starter | Controlled motor starting | Industrial machinery |
| Schneider ATS22C14Q | Altistart 22 Soft Starter | Motor soft start and stop | Industrial applications |
| Schneider ATS22C11S6U | Altistart 22 Soft Starter | Asynchronous motor starting | Motor-control systems |
A related model should not be selected based only on physical dimensions or the Altistart 22 family name. The motor, supply arrangement, starting duty, and load characteristics should be checked before substitution.
The ATS22C25S6 is used to control the starting and stopping of asynchronous motors. It is appropriate where direct-on-line starting would create an undesirable electrical or mechanical transition.
It controls the motor’s acceleration rather than applying the full starting condition abruptly. This can be useful for conveyors with belt loads and pump systems where a sudden transition may be undesirable.
No. The ATS22C25S6 is a soft starter. Its main purpose is to manage motor starting and stopping, whereas a variable-frequency drive can provide continuous motor-speed control during normal operation.
The motor characteristics, incoming electrical supply, starting duty, mechanical load, control arrangement, protection devices, and complete ATS22 model number should be checked. Physical dimensions alone are not sufficient for selecting a replacement.