The Ingersoll Rand 47661942001 80060239 Coolant is a compressor lubricant used in compatible Ingersoll Rand compressed-air equipment. In oil-injected compressor systems, the circulating coolant serves more than one purpose: it lubricates internal components while carrying heat away from the compression process.
During compressor operation, lubricant is circulated through the airend and associated lubrication circuit. The fluid is exposed to mechanical friction, compression heat, and continuous circulation, making coolant condition an important part of routine compressor maintenance. Correct lubricant selection helps maintain the intended operating condition of the compressor.
This product is suited to planned service work where the existing compressor coolant needs to be replaced. It can be used as part of preventive maintenance, lubricant service, or compressor overhaul when the applicable equipment specification calls for 80060239.
For service technicians, coolant replacement should be treated as part of the complete lubrication-system inspection. The condition of the filter, cooler, return circuit, seals, and other related components should also be checked while the system is being serviced.
| Parameter | Specification |
|---|---|
| Manufacturer | Ingersoll Rand |
| Part Number | 47661942001 |
| Coolant Number | 80060239 |
| Product Type | Compressor Coolant |
| Primary Function | Lubrication and cooling |
| System Role | Compressor lubrication and heat-management circuit |
| Application | Compatible Ingersoll Rand compressor systems |
| Capacity | 15 L |
| Weight | 15 kg |
Coolant Reservoir → Circulation Circuit → Compressor Airend → Heat and Friction Transfer → Cooler → Return Circuit
The coolant circulates through the compressor lubrication system during operation. At the airend, it assists with lubrication and absorbs heat generated by compression and mechanical movement. The heated fluid then passes through the cooling circuit before returning to the compressor for continued circulation.
The coolant circuit supports several operating functions:
As operating hours accumulate, lubricant can be affected by temperature, contamination, oxidation, and operating conditions. Regular coolant replacement helps keep the lubrication circuit within the intended service condition.
Air Intake → Compression Element → Coolant Injection/Circulation → Air/Oil Separation → Cooling Circuit → Lubrication Return
| System Element | Function |
|---|---|
| Compressor Airend | Performs the compression process and generates heat during operation |
| Coolant Circuit | Circulates lubricant through the compressor system |
| Air/Oil Separator | Removes lubricant from compressed air after the compression stage |
| Oil/Coolant Cooler | Removes heat from the circulating lubricant |
| Coolant Filter | Removes contaminants from the lubricant circuit |
| Oil Return Circuit | Returns separated lubricant to the compressor system |
| 80060239 Coolant | Provides lubrication and heat-transfer functions |
| Compressor Controller | Monitors compressor operating conditions and service functions |
| Application | Typical Use |
|---|---|
| Manufacturing Plants | Routine coolant replacement for plant air compressors |
| Automotive Production | Lubrication service for continuously operating compressed-air equipment |
| Metalworking | Compressor maintenance under demanding production conditions |
| Packaging Facilities | Preventive maintenance of production air systems |
| General Factory Utilities | Scheduled lubricant replacement for compressor packages |
| Compressor Service Centers | Coolant replacement during equipment servicing |
| Compressor Overhaul Projects | Refilling the lubrication circuit after major maintenance |
| Component | Function |
|---|---|
| Air/Oil Separator Element | Separates lubricant from compressed air |
| Compressor Oil Filter | Filters contaminants from the circulating lubricant |
| Compressor Air Filter | Removes particles from incoming compressor air |
| Oil/Coolant Cooler | Transfers heat away from the circulating lubricant |
| Oil Return Line | Returns separated lubricant to the compressor circuit |
| Compressor Airend | Compression assembly requiring lubrication and cooling |
| Coolant Circuit | Provides continuous lubricant circulation |
| Compressor Controller | Monitors operating parameters and maintenance conditions |
| Model / Product Family | Product Type | Typical Application |
|---|---|---|
| Ingersoll Rand 80060239 | Compressor Coolant | Compressor lubrication and cooling service |
| Ingersoll Rand 47661942001 | Compressor Service Part | Maintenance and fluid service |
| Ingersoll Rand Air/Oil Separator Elements | Separator Element | Oil-injected screw compressor maintenance |
| Ingersoll Rand Compressor Oil Filters | Oil Filter | Lubrication-system filtration |
| Ingersoll Rand Compressor Air Filters | Air Filter | Intake-air filtration |
| Ingersoll Rand Screw Compressor Service Components | Service Components | Preventive maintenance and overhaul |
The coolant circulates through the compressor lubrication system to lubricate working components and carry heat away from the compression process. Its condition affects the overall operating environment of the lubrication circuit.
The coolant filter, cooler, hoses, fittings, return circuit, and related seals should be inspected during fluid replacement. Any contamination or abnormal condition found in the drained coolant can also provide useful information about the condition of the lubrication system.
Different compressor lubricants should not be mixed unless their compatibility has been confirmed for the specific equipment. When changing lubricant types, the existing fluid should normally be drained according to the applicable service procedure.
Degraded or contaminated coolant can reduce lubrication performance and heat-transfer capability. It may also contribute to higher operating temperatures, increased component wear, or other lubrication-system problems. Following the specified service interval helps maintain the intended compressor operating condition.