• Ingersoll Rand 47572172001 47552954001 Thermostatic Valve Maintenance Kit
  • Ingersoll Rand 47572172001 47552954001 Thermostatic Valve Maintenance Kit
  • Ingersoll Rand 47572172001 47552954001 Thermostatic Valve Maintenance Kit
  • Ingersoll Rand 47572172001 47552954001 Thermostatic Valve Maintenance Kit
1. Product Overview The Ingersoll Rand 47572172001 / 47552954001 Thermostatic Valve Maintenance Kit is an industrial compressor maintenance product identified for servicing a compatible thermostatic val……
Ingersoll Rand 47572172001 47552954001 Thermostatic Valve Maintenance Kit
  • Ingersoll Rand
  • 47572172001 47552954001
  • Thermostatic Valve Maintenance Kit
  • USA
  • 180 × 120 × 80 mm
  • 1.0 kg
  • Xiamen, China
  • New & In Stock
  • T/T, PayPal, Western Union
  • 1 Year
  • 1-3 Working Days
  • DHL, UPS, TNT, FedEx and EMS.
  • 24-Hour Service
  • COO
  • 3

Our advantage

Ingersoll Rand 47572172001 47552954001 Thermostatic Valve Maintenance Kit

Global Logistics

We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.

Ingersoll Rand 47572172001 47552954001 Thermostatic Valve Maintenance Kit

Brand new and original

Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.

Ingersoll Rand 47572172001 47552954001 Thermostatic Valve Maintenance Kit

24-hour service

We provide 7*24 hours service to our customers. We will be there whenever you need us.

Ingersoll Rand 47572172001 47552954001 Thermostatic Valve Maintenance Kit

Price advantage

All our products are priced very favorably because we have our own warehouse and supply.


Company Information
E-mail [email protected]
Mobile +8615980777398
Whatsapp +8615980777398
WeChat 15980777398

1. Product Overview

The Ingersoll Rand 47572172001 / 47552954001 Thermostatic Valve Maintenance Kit is an industrial compressor maintenance product identified for servicing a compatible thermostatic valve assembly. Thermostatic valves are used in certain compressor systems to regulate fluid flow according to temperature conditions, helping maintain the intended thermal operating range of the equipment.

In industrial air compressors, temperature regulation is important for reliable operation, lubrication performance, and the management of heat generated during compression. Depending on the compressor design, a thermostatic valve may regulate the flow of lubricating oil through different paths to help control oil temperature. Proper valve operation can contribute to stable compressor performance and help prevent problems associated with unsuitable operating temperatures.

A maintenance kit provides components intended for servicing a compatible valve assembly. The exact contents, supported compressor models, and relationship between the supplied part numbers should be confirmed against the product label and applicable equipment parts documentation before ordering or installation.

The supplied product dimensions are 180 × 120 × 80 mm, and the listed weight is 1.0 kg. These specifications can assist with product identification, warehouse planning, and spare parts management.

2. Technical Specifications

Parameter Specification
Brand Ingersoll Rand
Part Number 47572172001
Additional Part Number 47552954001
Product Name Thermostatic Valve Maintenance Kit
Product Type Compressor Valve Maintenance Kit
Application Maintenance of a compatible thermostatic valve assembly
Dimensions 180 × 120 × 80 mm
Weight 1.0 kg
Equipment Category Industrial compressed-air equipment
Primary Function Servicing a thermostatic valve, subject to model compatibility
Installation Location Confirm for the applicable compressor configuration
Kit Contents Verify against the supplied parts list
Compatibility Confirm using the compressor model, serial number, and valve identification
Maintenance Objective Support proper valve operation and temperature regulation

The dimensions and weight above are the supplied product specifications. Detailed information such as the exact kit contents, seal materials, temperature range, valve opening characteristics, and supported compressor models should be verified before installation. These specifications should not be inferred from the part number alone.

3. Function and Working Principle

3.1 What Is a Thermostatic Valve?

A thermostatic valve is a temperature-responsive component used to regulate fluid flow within a system. Its internal mechanism responds to temperature changes and adjusts the flow path according to the design of the equipment.

In some oil-injected rotary screw compressors, a thermostatic valve helps regulate lubricating oil temperature by directing oil through different paths. Depending on the design and operating conditions, the valve may direct oil through an oil cooler or allow it to bypass the cooler when additional cooling is not required.

The specific flow arrangement varies by compressor model. Therefore, the operating principle and service procedure for the installed valve should be confirmed using the relevant equipment documentation.

3.2 Purpose of a Thermostatic Valve Maintenance Kit

The Ingersoll Rand 47572172001 / 47552954001 Thermostatic Valve Maintenance Kit is intended for servicing a compatible thermostatic valve assembly.

Depending on the manufacturer’s specified configuration, a maintenance kit may include replacement sealing elements or other service components needed during valve maintenance. However, the exact contents of this kit must be verified rather than assumed.

Using the correct maintenance kit helps technicians carry out planned service work while preserving the valve’s intended function. It does not eliminate the need to inspect the valve body and other reusable parts for wear or damage.

3.3 Temperature Regulation and Compressor Performance

Compressor temperature affects lubrication, internal clearances, and the performance of components exposed to heat. If a thermostatic valve does not operate as intended, the compressor may experience abnormal temperature behavior.

Potential symptoms include excessive operating temperature, slow warm-up, unstable temperature readings, or changes in cooling performance. These symptoms can also be caused by other issues, such as a restricted oil cooler, low oil level, unsuitable lubricant, or a problem with the cooling system.

A systematic diagnosis is therefore necessary before determining whether the thermostatic valve requires maintenance.

4. Role in Industrial Compressor Systems

Thermostatic valves support temperature management in compressor configurations that use temperature-responsive fluid-flow control. Maintaining the valve according to the manufacturer’s requirements can help preserve the designed thermal operating conditions.

4.1 Lubricating Oil Temperature Control

In applicable oil-injected compressors, the valve helps regulate the oil flow path based on temperature. Correct operation supports the compressor’s intended oil-temperature management strategy.

4.2 Oil Cooler Integration

Where a compressor uses a thermostatic valve to control oil flow through a cooler, the valve contributes to the interaction between the lubrication circuit and the cooling system. A sticking or incorrectly functioning valve may affect this flow arrangement.

4.3 Operating Stability

The compressor is designed to operate within specified temperature limits. A properly maintained thermostatic valve helps the system follow its intended temperature-control sequence, although overall performance also depends on the cooler, lubricant, airflow, sensors, and other components.

4.4 Planned Maintenance

A maintenance kit supports servicing when the valve assembly is suitable for repair. Replacing the specified service components may help avoid unnecessary replacement of the complete assembly, provided the remaining parts meet the manufacturer’s requirements.

5. Industrial Applications

The Ingersoll Rand 47572172001 / 47552954001 Thermostatic Valve Maintenance Kit may be considered for maintaining compatible compressor equipment. Actual suitability depends on the installed valve design and compressor configuration.

Manufacturing Facilities

Manufacturing plants use compressed air for pneumatic tools, automated machinery, production equipment, and material handling. Maintaining compressor temperature-control components supports reliable operation of the compressed-air supply.

Packaging Machinery

Packaging lines may use compressed air for actuators, product handling, and automated movement. Reliable compressor operation helps reduce interruptions that could affect production schedules.

Industrial Workshops

Workshops use compressors for pneumatic tools, equipment servicing, and general industrial tasks. Routine maintenance helps identify component deterioration before it causes unexpected downtime.

Process Industries

Process plants may rely on compressed air for instrumentation, actuators, and production equipment. Compressor maintenance should follow the equipment requirements and the quality standards applicable to the process.

Centralized Compressed-Air Systems

Facilities with centralized compressor rooms may maintain valve service kits and other spare parts to support scheduled maintenance. Correct product identification helps technicians select suitable components for the installed equipment.

These are general application environments for compatible compressor maintenance products. They do not confirm that the kit fits every Ingersoll Rand compressor model.

6. Installation and System Integration

Thermostatic valve maintenance should be performed by qualified personnel using the instructions applicable to the exact compressor and valve assembly. The following steps provide a general workflow and do not replace model-specific service procedures.

Step 1: Verify the Part Numbers

Confirm that the product is identified as 47572172001 / 47552954001. Compare the numbers with the equipment parts list, service records, and existing valve identification.

If the two numbers are being used as related or alternative identifiers, verify their relationship before ordering or fitting the kit.

Step 2: Identify the Compressor Model

Record the compressor model and serial number. Confirm that the maintenance kit is specified for the installed thermostatic valve assembly.

Do not rely only on product dimensions or visual similarity to establish compatibility.

Step 3: Shut Down and Isolate the Compressor

Stop the compressor using the approved shutdown procedure. Isolate electrical power in accordance with the site’s lockout/tagout requirements.

Allow hot components and fluids to cool as required. Before opening any part of the system, verify that relevant pressure has been safely released and that the equipment is in a safe condition for maintenance.

Never remove or disassemble a hot, pressurized valve assembly. Follow the manufacturer’s isolation, depressurization, and fluid-handling procedures.

Step 4: Prepare the Work Area

Use a clean work surface and suitable tools. Keep dust, debris, and other contaminants away from the valve and the compressor’s lubrication circuit.

Wear the personal protective equipment required by the site and the equipment’s service instructions.

Step 5: Inspect the Existing Valve

Inspect the valve assembly for contamination, leakage, corrosion, damaged sealing surfaces, or signs of wear. Check the accessible components for deformation or other visible defects.

If the valve body or another major component is damaged beyond the permitted service limits, a maintenance kit alone may not be sufficient.

Step 6: Replace the Specified Service Components

Disassemble the valve only as instructed by the applicable service documentation. Identify the original components and compare them with the parts supplied in the kit.

Install each replacement component in the correct position and orientation. Use only approved lubricants, sealing products, and assembly methods where specified.

Do not assume that all internal parts must be replaced, and do not reuse components that the service procedure explicitly requires to be renewed.

Step 7: Reassemble the Valve

Reassemble the valve according to the manufacturer’s procedure. Follow the specified tightening sequence and torque values where provided.

Check that components are correctly seated and that the valve assembly is free from visible installation defects.

Step 8: Restore the System and Test

Reconnect the equipment and restore power according to the approved commissioning procedure. Check the oil level and relevant connections as required by the compressor instructions.

Monitor operating temperature, pressure, alarms, and other available diagnostics. Inspect for leakage and confirm that the compressor follows its expected operating sequence before returning it to normal service.

7. Common Problems and Troubleshooting

A thermostatic valve fault may cause abnormal compressor temperature behavior, but similar symptoms can arise from other components. The following table provides general diagnostic guidance.

Symptom Possible Causes Recommended Checks
Compressor operating temperature is too high Thermostatic valve malfunction, restricted cooler, low oil level, or cooling-system issue Inspect the valve and cooling circuit; verify oil level and operating conditions
Compressor warms up more slowly than expected Valve flow path problem, operating conditions, or sensor issue Review the specified warm-up behavior and diagnostic readings
Temperature readings fluctuate Valve sticking, changing load, cooling instability, or sensor fault Compare readings with operating conditions and inspect relevant components
Oil leakage near the valve Damaged seals, incorrect assembly, loose connections, or damaged sealing surfaces Safely isolate and cool the equipment before inspection
Maintenance does not resolve the temperature problem Incorrect kit, damaged valve body, cooler restriction, or another system fault Verify kit compatibility and inspect the complete temperature-control system
Repeated valve-related faults Contamination, unsuitable operating conditions, or recurring component wear Review maintenance records and investigate the underlying cause

7.1 Check Operating Temperature

Compare the measured temperature with the limits specified for the compressor model. Consider the load, ambient temperature, ventilation, and the location of the measurement.

Do not change control settings or bypass the valve simply to suppress a temperature alarm. Such actions may conceal the underlying problem or cause the compressor to operate outside its intended conditions.

7.2 Inspect the Cooling System

If operating temperature is high, inspect the relevant cooling components according to the service procedure. A blocked cooler, restricted airflow, or another cooling-system problem can produce symptoms similar to a valve malfunction.

7.3 Verify Oil Level and Condition

For compressors that use lubricating oil in the relevant circuit, confirm that the oil level and lubricant type meet the equipment requirements. Contamination or unsuitable lubricant may affect system performance.

7.4 Inspect for Leakage

If oil leakage is present, isolate the compressor and allow the affected components to cool before inspection. Identify the source of the leak and check the applicable seals, fittings, and sealing surfaces.

Never inspect a suspected pressurized leak with bare hands or loosen a connection while the system remains pressurized.

7.5 Review Diagnostic Information

Record temperature readings, alarms, operating conditions, and any recent maintenance work. Use these details to distinguish a valve-related issue from a sensor, cooler, lubrication, or control-system problem.

8. Preventive Maintenance Recommendations

A structured maintenance program can help maintain compressor temperature-control performance and reduce avoidable downtime.

  • Follow the maintenance schedule: Use the service intervals specified for the exact compressor model and operating environment.
  • Monitor temperature trends: Record operating temperatures and investigate persistent deviations from normal conditions.
  • Inspect the valve assembly: Check for leakage, visible damage, contamination, and signs of abnormal operation.
  • Maintain the cooling system: Keep coolers, ventilation paths, and related components in the condition required by the manufacturer.
  • Use approved service kits: Verify the part number and compatibility before installing replacement components.
  • Maintain clean working conditions: Prevent debris from entering the valve or lubrication circuit during servicing.
  • Check lubricant condition: Follow the specified oil inspection and replacement requirements.
  • Document maintenance work: Record the kit number, service date, observed condition, and post-maintenance results.
  • Investigate repeated failures: Look for an underlying cause rather than repeatedly replacing components without diagnosis.
  • Manage spare parts carefully: Store kits in suitable conditions and protect them from contamination or damage.

The appropriate maintenance frequency depends on the compressor model, operating hours, ambient conditions, and the criticality of the compressed-air supply.

9. Compatible System Components

The following table lists component categories that may be relevant when maintaining a thermostatic valve. It does not establish compatibility with specific part numbers.

Component Category Maintenance Considerations
Thermostatic valve assembly Confirm the valve design and the maintenance kit specified for it
Valve seals and internal service components Verify dimensions, material requirements, and replacement instructions
Oil cooler Inspect for restriction, contamination, and cooling-performance issues where applicable
Lubricating oil circuit Check oil level, lubricant condition, and the approved flow arrangement
Temperature sensors Verify readings and diagnostic status if temperature behavior appears abnormal
Compressor control system Review alarms, operating sequences, and specified temperature limits
Associated piping and fittings Check for leakage, damage, and correct connections
Compressor service documentation Use the applicable model-specific parts list and maintenance instructions

Compatibility should be verified using the complete compressor and valve configuration. A shared manufacturer name or similar product description is not sufficient.

10. Replacement and Alternative Selection

When sourcing a replacement for the Ingersoll Rand 47572172001 / 47552954001 Thermostatic Valve Maintenance Kit, technical compatibility should take priority over price or physical appearance.

Selection Factor What to Verify
Main part number Confirm 47572172001 against the equipment parts information
Additional part number Verify the relationship of 47552954001 to the required kit
Valve configuration Ensure the kit is intended for the installed thermostatic valve
Kit contents Confirm the included service components and quantities
Dimensions Supplied dimensions are 180 × 120 × 80 mm
Weight Supplied product weight is 1.0 kg
Material requirements Verify seal and component materials where relevant
Compressor compatibility Check model, serial number, and valve identification
Product condition Check packaging, completeness, storage condition, and traceability
Installation requirements Confirm the service procedure and any additional parts required

A similar-looking maintenance kit is not necessarily an acceptable substitute. Differences in seals, valve construction, or internal components may affect fit and operation.

If the original kit is unavailable, select an alternative only after confirming technical equivalence through the applicable equipment parts information or an approved technical assessment.

11. Key Benefits of Using the Correct Maintenance Kit

Supports Temperature-Control Maintenance

A compatible maintenance kit provides specified service components for maintaining a thermostatic valve assembly.

Helps Preserve Intended Valve Operation

Correct servicing can help the valve maintain its designed response to temperature conditions, provided the valve body and other reusable parts remain serviceable.

Supports Compressor Reliability

Proper maintenance of temperature-control components contributes to the overall reliability of the compressor’s lubrication and cooling arrangements.

Can Reduce Unnecessary Assembly Replacement

When the valve is suitable for repair, replacing the specified service components may avoid replacing the complete assembly. The final decision should be based on inspection and the manufacturer’s service criteria.

Improves Spare Parts Management

Accurate part-number identification helps maintenance teams organize inventory and reduce the risk of selecting an incompatible kit.

Simplifies Product Identification

The supplied dimensions of 180 × 120 × 80 mm and weight of 1.0 kg support receiving inspection, storage planning, and product identification.

These benefits depend on selecting the correct kit and completing maintenance according to the requirements of the installed equipment.

12. Technical FAQs

Q1: What is the Ingersoll Rand 47572172001 / 47552954001?

It is identified as a Thermostatic Valve Maintenance Kit for servicing a compatible valve assembly in industrial compressor equipment. The exact supported models and kit contents should be verified before purchase.

Q2: What are the dimensions of this kit?

The supplied dimensions are 180 × 120 × 80 mm.

Q3: How much does the maintenance kit weigh?

The supplied product weight is 1.0 kg.

Q4: What does a thermostatic valve do in a compressor?

In applicable compressor designs, it regulates fluid flow according to temperature. In some oil-injected compressors, it helps control the oil flow path through or around an oil cooler.

Q5: What components are included in the maintenance kit?

The exact contents must be confirmed from the supplied parts list or product documentation. Specific seals, internal components, or other parts should not be assumed to be included without verification.

Q6: How can I confirm compatibility with my compressor?

Check the compressor model and serial number, identify the installed thermostatic valve, and compare the required part number with the applicable equipment parts information.

Q7: Can a faulty thermostatic valve cause high compressor temperature?

It can be one possible cause, depending on the compressor design. A restricted cooler, unsuitable oil level, cooling-system fault, or sensor problem can produce similar symptoms and should also be investigated.

Q8: Can the maintenance kit be installed while the compressor is operating?

No. The compressor must be shut down and isolated according to the approved service procedure. Relevant pressure must be released, and hot components and fluids must be allowed to cool as required before disassembly.

Q9: Should I replace the complete valve or use a maintenance kit?

That depends on the condition of the existing valve and the manufacturer’s service instructions. If the valve body or other major components are damaged beyond the permitted limits, a maintenance kit may not be sufficient.

Q10: What should be checked after maintenance?

Check the assembly, connections, relevant oil level, leakage, operating temperature, alarms, and system performance according to the compressor’s commissioning procedure.

13. Conclusion

The Ingersoll Rand 47572172001 / 47552954001 Thermostatic Valve Maintenance Kit is identified as a service product for maintaining a compatible thermostatic valve assembly in industrial compressor equipment. Its supplied dimensions are 180 × 120 × 80 mm, and its listed weight is 1.0 kg.

Thermostatic valves can play an important role in temperature regulation within compressor systems, particularly where the valve controls the flow of lubricating oil through different cooling paths. Correct maintenance helps preserve the intended operating conditions and supports reliable compressor performance.

Before purchasing or installing the kit, verify the part numbers, compressor model, valve configuration, and exact kit contents. Follow the applicable service instructions, isolate and cool the equipment before disassembly, inspect reusable components, and validate system operation after maintenance. Accurate component selection and systematic preventive maintenance help reduce avoidable downtime and support effective industrial compressor management.



Related Products

Get the latest price? We will reply as soon as possible (within 12 hours)

No:77501