Our advantage
Global Logistics
We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.
Brand new and original
Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.
24-hour service
We provide 7*24 hours service to our customers. We will be there whenever you need us.
Price advantage
All our products are priced very favorably because we have our own warehouse and supply.
| Company Information | |||
| [email protected] | |||
| Mobile | +8615980777398 | ||
| +8615980777398 | |||
| 15980777398 |

The Ingersoll Rand 15483514 92692284 Ultra Coolant is a compressor lubricant intended for use in compatible compressed-air equipment. Compressor coolant circulates through the lubrication system to support internal lubrication and, depending on the compressor design, assist with heat removal and sealing during operation.
During continuous compressor operation, the coolant is exposed to elevated temperatures, mechanical movement, and repeated circulation through the system. Its condition affects lubrication performance and the management of heat generated during compression. Using the appropriate coolant and maintaining the required fluid level are therefore important parts of routine compressor servicing.
For maintenance teams managing Ingersoll Rand equipment, the 15483514 and 92692284 identifiers help establish the product reference for purchasing, storage, and service planning. Before adding or replacing coolant, the required fluid specification and equipment compatibility should be confirmed. Different compressor models and lubricant formulations may have different service requirements, so product identification should be matched to the intended application.
| Parameter | Specification |
|---|---|
| Brand | Ingersoll Rand |
| Model Identification | 15483514 |
| Additional Part Number | 92692284 |
| Product Name | Ultra Coolant |
| Product Type | Compressor Coolant |
| Product Category | Compressor Lubricant |
| Primary Function | Lubrication and thermal management within compatible compressor systems |
| Application | Compatible industrial compressor systems |
| System Integration | Compressor lubrication and cooling circuit |
| Supply Format | Packaged coolant |
| Container Capacity | 5 L |
| Maintenance Method | Fluid-level checks and scheduled replacement |
| Product Identification | 15483514 / 92692284 |
| Weight | 18.6 kg |
The Ingersoll Rand 15483514 92692284 Ultra Coolant operates as part of the lubrication system in compatible compressor equipment. During operation, the coolant circulates through the designated circuit, helping lubricate relevant internal components and carry heat away from areas affected by compression and mechanical movement.
In oil-injected rotary screw compressors, the lubricant may also contribute to sealing between the rotating screw elements. The exact functions and flow arrangement depend on the compressor design. As the fluid circulates, it absorbs heat and returns through the system’s designated cooling or separation arrangement before continuing through the operating cycle.
Typical coolant circulation path:
Coolant reservoir or sump → Circulation through the lubrication circuit → Lubrication and heat absorption → Cooling or separation stage, where applicable → Return to the circuit
Coolant performance depends on the specified formulation, fluid condition, operating temperature, and service history. Contamination, degradation, or an incorrect fluid can affect lubrication and thermal management. Maintenance personnel should check for abnormal discoloration, contamination, leaks, or unusual fluid consumption when servicing the system.
Within a compatible industrial compressor, Ultra Coolant forms part of the fluid system that supports lubrication and heat management. It works alongside mechanical and fluid-handling components that circulate, cool, and manage the lubricant during compressor operation.
| System Component | Function | Relationship to the Coolant |
|---|---|---|
| Compressor Coolant | Supports lubrication and heat transfer according to the compressor design | Circulates through the designated fluid circuit |
| Airend | Compresses incoming air and contains internal moving components | Relies on the specified lubrication arrangement |
| Oil or Coolant Circulation Mechanism | Moves fluid through the system where applicable | Maintains circulation through the designated circuit |
| Oil Cooler | Transfers heat away from circulating fluid where fitted | Helps manage coolant operating temperature |
| Oil Separator | Separates entrained lubricant from compressed air in oil-injected systems | Supports fluid recovery and separation |
| Fluid Filter | Removes contaminants from circulating fluid where fitted | Helps control contamination in the lubrication circuit |
| Hoses and Fittings | Carry fluid between connected components | Maintain the required flow path |
| Temperature and Pressure Monitoring | Monitors operating conditions where installed | Helps identify abnormal system conditions |
The actual component arrangement depends on the compressor model. Coolant selection and servicing should follow the requirements of the installed equipment.
| Application Area | Typical Use | Relevance of the Coolant |
|---|---|---|
| Industrial Air Compressors | Routine maintenance of compatible compressor systems | Supports lubrication and heat management |
| Manufacturing Facilities | Maintenance of compressors supplying production equipment | Supports ongoing compressor service requirements |
| Process Plant Operations | Servicing compressed-air equipment used in industrial processes | Provides a specified fluid for compatible equipment |
| Pneumatic Equipment Supply | Maintenance of compressors serving pneumatic machinery | Supports the compressor’s fluid system |
| Preventive Maintenance Programs | Scheduled fluid inspection and replacement | Helps maintain consistent service practices |
| Compressor Overhaul | Fluid renewal during major maintenance | Supports recommissioning after approved service work |
| Spare Parts and Consumables Management | Storage and inventory control for compressor fluids | Provides a defined product reference and container capacity |
| Component | Function | Relationship to the Coolant |
|---|---|---|
| Compressor Airend | Performs the air compression process | Uses the lubrication arrangement specified for the compressor |
| Fluid Filter | Removes contaminants from circulating fluid where fitted | Helps maintain fluid cleanliness |
| Oil Cooler | Transfers heat away from circulating lubricant | Supports temperature management |
| Oil Separator Element | Separates entrained oil from compressed air in applicable systems | Supports fluid recovery |
| Fluid Reservoir or Sump | Holds the circulating fluid where provided | Supplies fluid to the lubrication circuit |
| Hoses and Fittings | Connect fluid-handling components | Carry coolant through the system |
| Temperature and Pressure Sensors | Monitor operating conditions where installed | Provide information for system monitoring |
| Model or Product Category | Product Type | Relationship |
|---|---|---|
| Ingersoll Rand 15483514 92692284 | Ultra Coolant | Specified product identification for maintenance and replenishment |
| Ingersoll Rand Compressor Coolants | Compressor Coolant | Related category for compressor fluid maintenance |
| Ingersoll Rand Compressor Oil Filters | Oil Filter | Related service component for fluid contamination control |
| Ingersoll Rand Compressor Oil Separators | Oil Separator Element | Related component for compatible oil-injected compressor systems |
| Ingersoll Rand Compressor Air Filters | Air Filter | Related consumable for intake-air filtration |
| Ingersoll Rand Compressor Service Kits | Maintenance Kit | May contain selected components for scheduled servicing |
It is a compressor coolant used in compatible equipment to support lubrication and heat management. Its precise role depends on the compressor’s fluid circuit and operating design.
The specified container capacity is 5 L. The quantity required for a service depends on the compressor model and its fluid-system requirements.
Do not assume that different compressor fluids are compatible. Mixing formulations may affect fluid performance or maintenance requirements. Confirm the specified fluid type and replacement procedure for the equipment before mixing or changing products.
The replacement interval depends on the compressor model, operating conditions, fluid specification, and maintenance schedule. Fluid condition and any signs of contamination or degradation should also be considered during servicing.