Our advantage
Global Logistics
We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.
Brand new and original
Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.
24-hour service
We provide 7*24 hours service to our customers. We will be there whenever you need us.
Price advantage
All our products are priced very favorably because we have our own warehouse and supply.
| Company Information | |||
| [email protected] | |||
| Mobile | +8615980777398 | ||
| +8615980777398 | |||
| 15980777398 |

The GE IC695PNS001CA PACSystems RX3i PROFINET Scanner Module is a network communication module used in GE PACSystems RX3i PLC platforms to provide PROFINET connectivity between the control system and distributed field devices.
As a PROFINET Scanner Module, the IC695PNS001CA enables the RX3i controller system to communicate with PROFINET-based I/O devices, remote stations, and industrial network components. It extends the PLC architecture by adding high-speed Ethernet-based communication capability for modern automation applications.
Unlike traditional I/O modules that directly process field signals, the PROFINET Scanner Module focuses on network-level data exchange. It manages communication between the RX3i controller and connected PROFINET devices, allowing distributed automation equipment to exchange process data with the main control system.
The module is commonly used in machine automation, manufacturing systems, and industrial production lines where reliable PROFINET communication and distributed I/O integration are required.
| Parameter | Specification |
|---|---|
| Manufacturer | GE |
| Model | IC695PNS001CA |
| Product Family | PACSystems RX3i |
| Product Type | PROFINET Scanner Module |
| Communication Interface | PROFINET / Industrial Ethernet |
| Primary Function | PROFINET Network Communication |
| System Application | PLC Distributed I/O Control |
| Installation | PACSystems RX3i Rack System |
| Dimensions | 150 × 35.6 × 125 mm |
| Weight | 0.513 kg |
The GE IC695PNS001CA PACSystems RX3i PROFINET Scanner Module provides network integration capability for industrial automation systems.
Key characteristics include:
The module selection should consider network topology, connected PROFINET devices, controller configuration, and application requirements.
The IC695PNS001CA operates as a communication bridge between the PACSystems RX3i controller platform and PROFINET field devices.
A simplified communication path is:
RX3i Controller → PROFINET Scanner Module → Industrial Ethernet Network → Remote I/O Devices
During operation, the module exchanges process data between the PLC control system and connected PROFINET devices. It manages network communication, transfers input data from remote devices to the controller, and sends output information from the PLC program back to field equipment.
The scanner module allows distributed devices to operate as part of a unified automation system, reducing the need for extensive point-to-point wiring and supporting flexible system layouts.
The IC695PNS001CA operates within the communication layer of the GE PACSystems RX3i automation architecture.
A typical system structure can be represented as:
Engineering Software → RX3i CPU → PROFINET Scanner Module → Remote I/O → Field Devices
| System Layer | Typical Function |
|---|---|
| RX3i CPU | Executes PLC control logic |
| PROFINET Scanner Module | Manages network communication |
| PROFINET Remote I/O | Collects and outputs field signals |
| Ethernet Network | Transfers automation data |
| Field Devices | Provide process information and receive commands |
| Engineering Tools | Configure and maintain the control system |
The module does not replace the PLC CPU or execute application programs. Its main role is providing communication access between the controller and distributed network devices.
The GE IC695PNS001CA PACSystems RX3i PROFINET Scanner Module is suitable for industrial systems requiring distributed PROFINET communication.
| Application | Typical Use |
|---|---|
| Factory Automation | Connecting distributed I/O stations |
| Machine Manufacturing | Integrating remote control devices |
| Packaging Systems | Supporting network-based automation |
| Production Lines | Expanding PLC communication capability |
| Material Handling | Connecting distributed field equipment |
| Process Equipment | Data exchange between control stations |
| Industrial Ethernet Systems | PROFINET network integration |
| Legacy PLC Upgrades | Expanding RX3i communication functions |
The actual application depends on the PLC configuration, network design, and connected PROFINET devices.
Correct network configuration and installation are important for maintaining stable communication performance.
Recommended maintenance checks include:
If communication faults occur, troubleshooting should include the scanner module, Ethernet cables, network switches, device configuration, remote I/O status, and PLC program settings.
The IC695PNS001CA works together with various PACSystems RX3i automation components.
| Component | Function |
|---|---|
| GE PACSystems RX3i CPU | Executes PLC application logic |
| PROFINET Scanner Module | Provides network communication |
| Remote I/O Modules | Acquire and output field signals |
| Ethernet Switches | Support industrial network connections |
| Communication Modules | Expand system connectivity |
| Power Supply Modules | Provide rack power |
| Engineering Software | Configure PLC hardware and programs |
| Field Devices | Exchange process information |
These components form a complete distributed industrial automation network.
| Model / Product Family | Product Type | Typical Application |
|---|---|---|
| GE IC695PNS001CA | PACSystems RX3i PROFINET Scanner Module | PROFINET device integration |
| GE IC695PNC001 | PACSystems RX3i PROFINET Controller Module | PROFINET network control |
| GE IC695ETM001 | Ethernet Interface Module | Industrial Ethernet communication |
| GE PACSystems RX3i Communication Modules | Network Expansion Modules | PLC system networking |
| GE RX3i I/O Modules | Modular I/O Hardware | Field signal processing |
| GE RX3i CPU Modules | PLC Controller Modules | Automation program execution |
Selection should be based on network requirements, controller type, communication protocol, and existing PACSystems RX3i architecture.
The module adds PROFINET scanner capability to the RX3i platform, allowing the controller to exchange process data with distributed PROFINET devices and remote I/O stations.
The module is typically used with compatible PROFINET devices, including distributed I/O stations and industrial Ethernet-based automation components.
Network configuration, Ethernet cable quality, device parameters, topology design, and correct PLC hardware configuration all influence communication performance.
A scanner module is useful when an automation system requires distributed device connections, flexible network expansion, and reduced field wiring complexity.