Product Overview The GE IC695ECM850 PACSystems RX3i Series Ethernet Communication Module is a network interface module used in GE PACSystems RX3i programmable automation controllers (PAC) to provide Eth……
GE IC695ECM850 PACSystems RX3i Series Ethernet Communication Module
  • GE
  • IC695ECM850
  • Ethernet Communication Module
  • USA
  • 130 × 35 × 100 mm
  • 0.45 kg
  • Xiamen, China
  • New & In Stock
  • T/T, PayPal, Western Union
  • 1 Year
  • 1-3 Working Days
  • DHL, UPS, TNT, FedEx and EMS.
  • 24-Hour Service
  • COO
  • 18

Our advantage

GE IC695ECM850 PACSystems RX3i Series Ethernet Communication Module

Global Logistics

We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.

GE IC695ECM850 PACSystems RX3i Series Ethernet Communication Module

Brand new and original

Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.

GE IC695ECM850 PACSystems RX3i Series Ethernet Communication Module

24-hour service

We provide 7*24 hours service to our customers. We will be there whenever you need us.

GE IC695ECM850 PACSystems RX3i Series Ethernet Communication Module

Price advantage

All our products are priced very favorably because we have our own warehouse and supply.


Company Information
E-mail [email protected]
Mobile +8615980777398
Whatsapp +8615980777398
WeChat 15980777398

Product Overview

The GE IC695ECM850 PACSystems RX3i Series Ethernet Communication Module is a network interface module used in GE PACSystems RX3i programmable automation controllers (PAC) to provide Ethernet-based communication between the control system and external devices, supervisory platforms, and industrial networks.

In modern automation architectures, Ethernet communication is essential for connecting PLC/PAC controllers with SCADA systems, engineering workstations, industrial servers, and other automation equipment. The IC695ECM850 expands the communication capability of the RX3i platform by providing a dedicated Ethernet interface for data exchange, system integration, and remote monitoring applications.

The module is installed on the RX3i backplane and works together with RX3i CPUs, power supplies, I/O modules, and communication devices. It is commonly applied in manufacturing automation, process control, and distributed industrial systems requiring reliable network connectivity.


Technical Specifications

Parameter Specification
Manufacturer GE
Model IC695ECM850
Product Series PACSystems RX3i
Product Type Ethernet Communication Module
Function Industrial Ethernet Network Interface
System Compatibility GE PACSystems RX3i
Communication Type Ethernet Communication
Installation RX3i Backplane
Application PLC Network Integration
Dimensions 130 × 35 × 100 mm
Weight 0.45 kg

Product Features

The GE IC695ECM850 provides Ethernet communication capability for PACSystems RX3i automation systems.

Key features include:

  • GE PACSystems RX3i compatible communication module
  • Provides Ethernet network connectivity
  • Enables communication between PAC controllers and external systems
  • Supports distributed automation architectures
  • Simplifies PLC network integration
  • Supports connection with supervisory and engineering systems
  • Compact design for control cabinet installation
  • Enhances data exchange capability of RX3i systems
  • Supports modular PAC system expansion
  • Suitable for industrial communication applications

The module allows RX3i systems to participate in Ethernet-based automation networks.


Working Principle

The IC695ECM850 operates as a communication bridge between the RX3i controller system and Ethernet-connected devices.

Typical communication structure:

SCADA / HMI / Engineering Station → Ethernet Network → IC695ECM850 → RX3i Backplane → CPU Module

Operating process:

  1. External devices send communication data through the Ethernet network.
  2. The IC695ECM850 receives and manages network communication packets.
  3. Data is transferred through the RX3i backplane to the controller system.
  4. The CPU processes the information according to the configured control program.
  5. Process data, status information, and control commands are exchanged between connected systems.

The communication module expands the PAC system’s connectivity without affecting the execution of the main control program.


Role in PACSystems RX3i Architecture

The IC695ECM850 plays an important communication role within the RX3i control platform.

Component Function
RX3i CPU Module Executes control logic
Ethernet Communication Module Provides network interface
Power Supply Module Supplies rack power
I/O Modules Collect field signals
Communication Network Transfers system data
SCADA/HMI System Provides monitoring interface

The module enables RX3i controllers to integrate with higher-level automation and information systems.


Industrial Applications

The GE IC695ECM850 is commonly used in industrial environments requiring Ethernet-based control communication.

Application Typical Use
Manufacturing Automation PLC network communication
Process Industry DCS/SCADA data integration
Packaging Systems Machine communication
Energy Systems Equipment monitoring networks
Water Treatment Remote control communication
Material Handling Distributed automation systems

It is suitable for applications requiring reliable communication between field control equipment and supervisory systems.


Installation and Maintenance

Proper configuration and installation are essential for stable Ethernet communication.

Recommended practices include:

  • Confirm compatibility with PACSystems RX3i hardware.
  • Install the module in the correct RX3i rack position.
  • Configure network parameters correctly.
  • Verify Ethernet cable connections.
  • Check communication status indicators.
  • Maintain proper network addressing.
  • Inspect connectors during scheduled maintenance.

Regular network monitoring helps prevent communication interruptions caused by configuration or connection issues.


Compatible System Components

The GE IC695ECM850 is commonly used with:

Component Function
GE IC695 CPU Modules Execute automation programs
PACSystems RX3i Rack Provides hardware installation platform
RX3i Power Supply Modules Provide system power
RX3i I/O Modules Handle field signals
Ethernet Switches Extend industrial networks
SCADA/HMI Systems Monitor and operate processes

These components work together to create an integrated industrial automation network.


Recommended Related Models

Model Product Type Application
GE IC695ECM850 RX3i Ethernet Communication Module Industrial Ethernet networking
GE IC695ETM001 RX3i Ethernet Interface Module Ethernet communication expansion
GE IC695CMM004 RX3i Serial Communication Module Serial device integration
GE IC694MDL732 RX3i Discrete Output Module Digital actuator control
GE IC694MDL640 RX3i Discrete Input Module Digital signal acquisition

Model selection should consider network architecture, communication protocol requirements, connected devices, and RX3i system configuration.


Key Advantages

  • Expands GE RX3i Ethernet communication capability
  • Enables integration with industrial networks
  • Supports communication between PAC systems and supervisory platforms
  • Simplifies automation system networking
  • Improves data exchange efficiency
  • Supports distributed control architectures
  • Reduces additional communication hardware requirements
  • Suitable for modern industrial automation environments

Technical FAQs

What is the main function of the GE IC695ECM850?

The IC695ECM850 provides Ethernet communication capability for GE PACSystems RX3i controllers, allowing them to exchange data with external automation systems.

Where is the IC695ECM850 installed?

The module is installed directly on the PACSystems RX3i backplane and operates together with CPU, power supply, and I/O modules.

What systems can communicate with the IC695ECM850?

It can be integrated with Ethernet-based industrial devices, supervisory systems, engineering tools, and other compatible automation equipment.

How does the IC695ECM850 improve an RX3i control system?

It extends network connectivity, enabling remote monitoring, system integration, and communication with higher-level automation platforms.