Our advantage
Global Logistics
We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.
Brand new and original
Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.
24-hour service
We provide 7*24 hours service to our customers. We will be there whenever you need us.
Price advantage
All our products are priced very favorably because we have our own warehouse and supply.
| Company Information | |||
| [email protected] | |||
| Mobile | +8615980777398 | ||
| +8615980777398 | |||
| 15980777398 |

The EPRO PR9350/04 Inductive Sensor is an industrial displacement transducer designed for monitoring the dynamic movement and position of rotating machinery components. It belongs to the PR9350 series and is intended for critical equipment such as steam turbines, gas turbines, hydro turbines, compressors, pumps, and industrial fans.
Unlike a conventional inductive proximity switch that simply detects the presence or absence of a metal object, the PR9350/04 is designed to measure mechanical displacement. It uses an inductive half-bridge measuring principle with a moving ferromagnetic core. The sensor converts mechanical movement into an electrical signal that can be processed by a compatible monitoring or signal-conditioning device.
The PR9350/04 has a measuring range of ±50 mm and a sensitivity of 270 mV/V. Its specified linearity error is 2.5%, making it suitable for applications that require continuous displacement information rather than simple switching signals.
In rotating machinery, shaft movement can provide important information about equipment operating conditions. Radial displacement, axial displacement, shaft position, and eccentricity are among the parameters that engineers may need to monitor when evaluating machine condition.
The sensor operates with an excitation voltage of 5 V RMS and a carrier frequency between 3 and 5 kHz. It is designed for an operating temperature range of -20°C to +100°C. These characteristics support its use in industrial monitoring installations where reliable measurement is important for equipment protection and maintenance.
The PR9350/04 is a passive measuring element and should be used with a compatible transmitter or monitoring card. It is not a standalone PLC input device. Correct signal conditioning, mechanical installation, and calibration are essential for obtaining meaningful measurement results.
| Parameter | Specification |
|---|---|
| Brand | EPRO |
| Manufacturer | Emerson |
| Model | PR9350/04 |
| Product Series | PR9350 |
| Product Type | Inductive Displacement Sensor |
| Measuring Principle | Inductive half-bridge with moving core |
| Measuring Range | ±50 mm |
| Sensitivity | 270 mV/V |
| Linearity Error | 2.5% |
| Supply / Excitation Voltage | 5 V RMS |
| Carrier Frequency | 3–5 kHz |
| Capacitance | 250 pF per winding |
| Operating Temperature | -20°C to +100°C |
| Temperature Error | Less than 3% |
| Maximum Diameter Provided | 25 mm |
| Reference Diameter in Technical Drawing | 25.4 mm |
| Weight Provided | 0.37 kg |
| Physical Reference Weight | 370 g |
| Typical Application | Radial and axial displacement measurement |
| Compatible Signal Conditioning | Dedicated transmitter or compatible monitoring card |
Note: The maximum diameter and weight are based on the supplied product information and the PR9350 technical specification. Overall dimensions depend on the mechanical drawing and should be checked before preparing a mounting arrangement.
The PR9350/04 measures mechanical displacement through changes in the electrical characteristics of an inductive measuring element. Its design uses two coil windings and a movable ferromagnetic core connected to a mechanical sensing arrangement.
The sensor contains an inductive half-bridge with a moving core. When the core is positioned at the nominal center point, the electrical characteristics of the two windings are balanced.
As the core moves in one direction, the impedance of one winding changes relative to the other. Movement in the opposite direction produces the opposite change.
The resulting electrical imbalance provides a signal related to the displacement of the moving core. This allows the connected measuring system to determine both the direction and magnitude of mechanical movement within the specified measuring range.
The PR9350/04 provides a measuring range of ±50 mm around its nominal center position.
This range can be useful when monitoring machinery components that move in both directions relative to a reference position. Examples include shaft axial movement, mechanical position changes, and displacement associated with rotating equipment operation.
The measurement range should not be confused with a switching distance. The sensor provides a continuous measurement signal rather than a simple ON/OFF output.
The sensor requires an excitation supply of 5 V RMS with a carrier frequency between 3 and 5 kHz.
Its sensitivity is specified as 270 mV/V. This value describes the relationship between the sensor’s output and its excitation voltage under the specified measurement conditions.
A compatible transmitter or monitoring card is required to excite the sensor, process the measurement signal, and provide an output suitable for the wider monitoring or control system.
The moving core is connected to a mechanical sensing arrangement. When the monitored component moves, the core position changes and produces a corresponding electrical response.
For rotating machinery, the mechanical installation determines which movement is transferred to the sensor. Proper alignment, mounting stability, and mechanical contact conditions are therefore important.
The sensor should be installed according to the manufacturer’s mechanical instructions to avoid unwanted friction, excessive movement, or measurement distortion.
The specified operating temperature range is -20°C to +100°C, with a temperature error below 3%.
Temperature conditions can influence the electrical characteristics of inductive measuring elements. Correct installation and use within the specified environmental limits help maintain measurement consistency.
The EPRO PR9350/04 is intended to work as part of a complete machinery monitoring arrangement. It provides the displacement measurement element, while associated signal-conditioning and monitoring equipment interprets the sensor output.
Turbines operate under changing thermal, mechanical, and rotational conditions. Shaft movement can be an important parameter when evaluating machine behavior.
The PR9350/04 can be used in a suitable measurement arrangement to monitor radial or axial displacement. The resulting data may help maintenance engineers identify abnormal movement or changes from established operating conditions.
Industrial compressors contain rotating assemblies that operate under significant mechanical loads. Displacement information can support machinery condition assessment when combined with other measurements such as vibration, speed, and temperature.
The sensor’s suitability depends on the required measurement direction, range, mechanical interface, and monitoring-system configuration.
Large pumps and fans may experience changes in shaft position or mechanical alignment as operating conditions vary. Continuous displacement measurement can provide additional information for maintenance and equipment assessment.
The PR9350/04 can be incorporated into an appropriate monitoring arrangement where its measuring range and mechanical design meet the application requirements.
The sensor should be connected to compatible signal-conditioning equipment rather than treated as a conventional two-wire or three-wire proximity switch.
The PR9350 series is designed to operate with dedicated transmitter or monitoring-card equipment. The complete measurement chain should be verified, including excitation, sensor wiring, signal processing, scaling, and monitoring-system input configuration.
Steam turbines operate under high mechanical and thermal loads. Shaft displacement monitoring can help maintenance teams evaluate the movement of rotating components during startup, normal operation, and shutdown.
The PR9350/04 may be used where a ±50 mm measuring range is appropriate for the required displacement measurement.
Gas turbines require continuous monitoring of critical operating parameters. Displacement measurements can complement vibration and other machinery condition data.
The sensor can form part of a properly designed monitoring arrangement when its environmental and mechanical specifications meet the turbine installation requirements.
Hydro turbine assemblies contain rotating shafts and supporting structures that may require displacement monitoring. Changes in shaft position can provide useful information during operation and maintenance.
The PR9350/04 offers a continuous measuring range suitable for applications that require bidirectional displacement measurement within its specified limits.
Compressors are commonly used in petrochemical plants, refineries, power facilities, and manufacturing operations. Monitoring shaft movement can support equipment condition assessment and maintenance planning.
The sensor should be selected according to the compressor’s mechanical arrangement and the required measurement location.
Large process pumps may operate continuously under varying flow and pressure conditions. Shaft displacement information can be useful when evaluating mechanical movement and alignment-related conditions.
The PR9350/04 can be considered for applications where its measurement principle, range, and installation requirements are suitable.
Large fans and ventilation systems may contain rotating shafts that require condition monitoring. Displacement measurement can complement vibration monitoring and provide additional information about mechanical movement.
The installation should account for the fan’s mechanical configuration, vibration environment, and sensor mounting requirements.
Correct installation is essential for accurate displacement measurement. The PR9350/04 should be installed as part of a complete measurement system with suitable mechanical mounting and electrical signal conditioning.
The PR9350/04 provides a nominal measuring range of ±50 mm.
Before installation, determine the expected mechanical displacement and confirm that the sensor’s range is appropriate. The nominal center position should be established according to the manufacturer’s instructions.
The monitored component must remain within the permitted measurement range during all relevant operating conditions.
The sensor must be securely mounted so that unwanted movement of the sensor housing does not affect the measurement.
The mechanical arrangement should allow the moving core to follow the intended displacement without binding or excessive friction. Check the alignment and movement of the sensing mechanism before commissioning.
Use the manufacturer’s mechanical drawing to confirm mounting-hole positions, installation clearances, and connection requirements.
The PR9350/04 requires 5 V RMS excitation at a carrier frequency of 3–5 kHz.
A compatible transmitter or monitoring card is needed to supply the excitation and process the sensor signal. Verify the supported sensor type, excitation specifications, wiring configuration, and input characteristics before connecting the equipment.
Do not connect the sensor directly to an ordinary PLC analog input unless a suitable signal-conditioning interface is installed.
Inspect the sensor connector and cable before installation. Confirm that the connector type, pin assignments, cable condition, and shielding arrangement match the applicable documentation.
Keep sensor wiring appropriately separated from high-power conductors and sources of electrical interference. Follow the grounding and shielding instructions for the complete monitoring system.
Before normal operation, establish the correct mechanical reference or zero position.
The reference position is important because displacement measurements are interpreted relative to the sensor’s nominal center. Incorrect positioning can reduce the usable measurement range or produce misleading readings.
Follow the manufacturer’s commissioning procedure when setting the initial position and measurement scaling.
After installation, confirm that the signal-conditioning equipment recognizes the sensor correctly. Check the output response while the monitored mechanism is moved through an appropriate test range.
Verify that the signal changes in the expected direction and that the displayed displacement corresponds to the actual mechanical movement.
Periodically inspect the sensor mounting, mechanical linkage, connector, and cable. Look for loose fasteners, damaged insulation, corrosion, or signs of mechanical wear.
Maintenance intervals should be determined according to equipment criticality, operating conditions, and the plant’s machinery monitoring procedures.
The PR9350/04 is normally used with additional equipment to form a complete displacement measurement system.
| Component | Function | Integration Considerations |
|---|---|---|
| Compatible transmitter | Supplies excitation and conditions the sensor signal | Confirm PR9350 compatibility and electrical specifications |
| A6500-LC transmitter | Dedicated signal-conditioning option for compatible sensor arrangements | Verify exact hardware and configuration |
| A6410 monitoring card | Processes compatible displacement sensor signals | Confirm system version and channel configuration |
| Machinery protection system | Monitors equipment operating conditions | Check supported measurement type and signal scaling |
| Sensor cable | Carries excitation and measurement signals | Confirm connector, pinout, shielding, and cable condition |
| Mechanical mounting assembly | Holds the sensor in the correct position | Follow the sensor’s installation drawing |
| PLC or DCS | Receives processed information for plant control or display | Use a suitable transmitter or monitoring-system output |
| Operator monitoring interface | Displays displacement values and alarms | Confirm scaling, engineering units, and alarm configuration |
The components listed are examples of equipment used in a complete measurement arrangement. They are not necessarily supplied with the PR9350/04 sensor.
The PR9350 series includes several measuring-range options. Selecting an alternative requires matching the measurement range, sensitivity, linearity, mechanical dimensions, and system compatibility.
| Model | Measuring Range | Sensitivity | Linearity Error |
|---|---|---|---|
| PR9350/01 | ±12 mm | 110 mV/V | 3.5% |
| PR9350/02 | ±25 mm | 270 mV/V | 3.5% |
| PR9350/04 | ±50 mm | 270 mV/V | 2.5% |
| PR9350/06 | ±75 mm | 310 mV/V | 2.0% |
| PR9350/08 | ±100 mm | 310 mV/V | 2.0% |
| PR9350/12 | ±150 mm | 340 mV/V | 1.5% |
When replacing a PR9350/04, consider the following:
A sensor from the same product family is not automatically a direct replacement. Models with different measuring ranges may also have different physical dimensions and electrical characteristics.
The PR9350/04 provides a continuous measurement signal rather than a simple switching output. This makes it suitable for applications that require information about the magnitude and direction of mechanical movement.
Its bidirectional measuring range supports applications where displacement may occur in either direction relative to a nominal center position.
The moving-core measurement principle converts mechanical displacement into an electrical signal that can be processed by compatible monitoring equipment.
The sensor is designed for demanding machinery monitoring applications, including turbines, compressors, pumps, and fans.
The specified 5 V RMS excitation and 3–5 kHz carrier frequency provide clear electrical parameters for selecting compatible signal-conditioning equipment.
The availability of multiple measuring-range variants allows engineers to select a sensor according to the required displacement range and measurement performance.
The EPRO PR9350/04 is an inductive displacement sensor designed for measuring mechanical movement in critical rotating machinery. It is part of the PR9350 series and uses a moving-core inductive half-bridge measuring principle.
Its specified measuring range is ±50 mm. This represents displacement in both directions relative to the nominal center position.
No. It is a displacement transducer designed for continuous measurement. It should not be treated as an ordinary ON/OFF proximity switch.
The specified sensitivity is 270 mV/V. The actual signal interpretation depends on the excitation supply and the connected signal-conditioning equipment.
The PR9350/04 requires an excitation voltage of 5 V RMS, with a carrier frequency between 3 and 5 kHz.
The specified operating temperature range is -20°C to +100°C. Installation conditions should remain within the manufacturer’s limits.
It is not intended to be connected directly to an ordinary PLC analog input. A compatible transmitter or monitoring card is required to provide excitation and condition the sensor signal before integration with a PLC or DCS.
Compatible signal-conditioning equipment includes dedicated transmitter or monitoring-card arrangements, such as suitable A6500-LC or A6410 configurations. Confirm the exact hardware compatibility before installation.
The physical specification lists the PR9350/04 at approximately 370 g, equivalent to 0.37 kg. Packaging and shipping weight may be different.
Confirm the full model number, measuring range, sensitivity, linearity, mechanical dimensions, connector, cable wiring, excitation requirements, and compatibility with the existing transmitter or monitoring card.
When purchasing the EPRO PR9350/04, verify the complete model number and ensure that the measuring range matches the installed application. The PR9350 series contains several variants, and selecting the wrong range may affect the measurement system’s accuracy and usable travel.
For replacement projects, compare the sensor’s electrical characteristics with the existing transmitter or monitoring card. The excitation voltage, carrier frequency, connector, and wiring configuration should all be confirmed before installation.
For used or refurbished equipment, request clear photographs of the product label, connector, housing, and mechanical sensing assembly. Check for damage to the moving core, mounting points, cable connection, and protective housing. Where the sensor is used in a critical machinery protection system, appropriate functional testing should be completed before returning it to service.
During routine maintenance, inspect mounting stability, mechanical alignment, connector condition, and cable integrity. Verify the reference position and measurement signal according to the plant’s maintenance procedures.
For critical turbines and compressors, displacement measurements should be interpreted together with other machinery condition parameters. A single sensor reading should not be used as the only basis for diagnosing a mechanical fault.
The EPRO PR9350/04 Inductive Sensor is a specialized displacement transducer for critical industrial machinery monitoring. With a measuring range of ±50 mm, sensitivity of 270 mV/V, and specified linearity error of 2.5%, it is designed to provide continuous displacement information for suitable turbine, compressor, pump, and fan applications.
Its 5 V RMS excitation requirement and 3–5 kHz carrier frequency mean that compatible signal-conditioning equipment is essential. Correct mechanical installation, reference positioning, wiring, and system configuration are equally important for reliable measurement.
For industrial maintenance and replacement projects, verifying the complete PR9350/04 model and its compatibility with the installed monitoring equipment helps ensure that the sensor can perform its intended measurement function.