The EPRO PR6424/013-140 + CON021 Eddy Current Sensor is an eddy current measurement assembly designed for non-contact monitoring of rotating machinery. It is used in industrial condition-monitoring applications where accurate information about shaft movement, displacement, vibration, and mechanical position is required.
The assembly combines an EPRO PR6424 series proximity probe with a CON021 signal converter. The probe detects changes in the distance between its sensing tip and a conductive metallic target. The converter conditions the resulting measurement signal and provides an electrical output that can be connected to compatible machinery monitoring equipment.
Unlike contact-based measurement devices, an eddy current sensor does not need to physically touch the rotating shaft. This makes the technology suitable for continuous monitoring of rotating equipment, including turbines, compressors, pumps, motors, and other machinery with critical rotating components.
The PR6424 series is part of EPRO’s industrial proximity measurement technology. When installed with a compatible extension cable and signal converter, the sensor forms a measuring chain for monitoring shaft displacement and dynamic movement. Correct probe, cable, converter, and target-material matching is essential for accurate measurement.
The CON021 converter provides signal conditioning for the compatible probe system. It helps transform the probe’s measurement response into a usable electrical signal for a monitoring or protection system. The final output characteristics depend on the converter configuration and the associated measuring-chain components.
The supplied product listing identifies the assembly as PR6424/013-140 + CON021, with a sensor head diameter of 16 mm and a weight of 0.32 kg. However, the PR6424/013 model designation is described in available product information as a 13 mm probe-tip version. Buyers should verify the exact probe dimensions and configuration against the product nameplate before ordering.
| Parameter | Specification |
|---|---|
| Brand | EPRO |
| Manufacturer | Emerson EPRO |
| Probe Model | PR6424/013-140 |
| Converter Model | CON021 |
| Product Type | Eddy Current Sensor / Proximity Measurement Assembly |
| Measurement Technology | Eddy Current |
| Measurement Method | Non-contact displacement measurement |
| Application | Shaft vibration, displacement, and position monitoring |
| Sensor Head Diameter | 16 mm as supplied; verify against exact probe variant |
| Model Code Note | PR6424/013 is described in available listings as a 13 mm tip version |
| Probe Configuration | PR6424 series |
| Signal Conditioning | CON021 converter |
| Weight Provided | 0.32 kg |
| Typical Target | Conductive ferromagnetic metallic shaft |
| System Components | Probe, compatible cable, and signal converter |
| Typical Installation | Rotating machinery monitoring system |
Note: The 16 mm description and PR6424/013 model designation should be checked against the actual nameplate and original technical documentation. Exact measuring range, sensitivity, cable length, temperature limits, and output characteristics depend on the complete measuring-chain configuration.
The PR6424/013-140 + CON021 assembly uses the eddy current principle to measure the distance between a probe and a conductive metallic target. This technology is widely used for non-contact monitoring of rotating machinery.
An eddy current probe contains a sensing coil that generates an alternating electromagnetic field. When the probe is positioned near a conductive metallic target, the electromagnetic field induces small circulating electrical currents in the target material.
These currents affect the electromagnetic characteristics of the probe. Changes in the gap between the probe and the target therefore produce measurable changes in the probe’s electrical response.
The system uses this relationship to determine the relative distance between the probe tip and the shaft surface.
Because the probe does not need to touch the shaft, it can continuously monitor mechanical movement without introducing contact wear at the measurement point.
During machinery operation, rotating shafts may move because of bearing clearance, mechanical loading, thermal expansion, imbalance, misalignment, or other operating conditions.
An eddy current probe can detect changes in the shaft-to-probe gap. The resulting signal provides information about shaft displacement and relative position.
This measurement is useful for identifying changes in machine behavior and supporting condition-based maintenance.
The PR6424 probe generates a measurement response that must be processed before it can be used by a monitoring system.
The CON021 converter is designed to work with compatible EPRO proximity probes. It conditions the probe signal and produces an electrical output corresponding to the measured displacement.
The converter configuration, power supply, output scaling, and wiring must match the specific probe and monitoring-system requirements. The CON021 should not be assumed to provide a standard 4–20 mA output unless that capability is confirmed for the exact configuration.
When installed at an appropriate measurement location, the probe can provide continuous information about shaft movement.
A monitoring system can use this information to identify changes in vibration or shaft position. Operators and maintenance personnel can then investigate abnormal trends before they develop into more serious equipment problems.
The measurement quality depends on correct installation, probe clearance, target material, cable compatibility, converter configuration, and system calibration.
The PR6424/013-140 + CON021 measuring assembly can be used as part of a machinery protection or condition-monitoring system.
Shaft vibration is an important indicator of rotating machinery condition. Changes in vibration can be associated with imbalance, misalignment, bearing deterioration, looseness, or other mechanical problems.
A properly installed eddy current probe measures relative shaft movement and supplies information that can be evaluated by compatible monitoring equipment.
The probe can also be used to monitor the relative position of a shaft. This is important in machinery where axial or radial movement must remain within defined operating limits.
Position measurements can help maintenance teams identify changes in bearing clearances, mechanical loading, or machine alignment.
In critical rotating machinery, displacement measurements may be connected to a dedicated monitoring and protection system. The monitoring equipment evaluates the signal against configured alarm and shutdown limits.
The sensor itself does not independently provide complete machinery protection. Reliable protection requires compatible monitoring hardware, correct channel configuration, appropriate alarm settings, and a properly engineered shutdown strategy.
The conditioned output from the measuring chain may be connected to compatible monitoring equipment or automation systems. Depending on the system architecture, measurement information can be made available to a DCS, PLC, or supervisory monitoring platform.
Engineers must verify electrical signal compatibility, channel scaling, grounding, and isolation requirements before integration.
EPRO PR6424 series eddy current sensors are intended for industrial machinery measurement applications where non-contact shaft monitoring is required.
Steam turbines operate at high rotational speeds and require reliable monitoring of shaft movement and vibration. Eddy current probes can be installed at suitable bearing locations to measure relative shaft displacement.
Continuous measurement helps operators evaluate changes in turbine operating conditions and identify abnormal mechanical behavior.
Gas turbines contain high-speed rotating components that operate under demanding thermal and mechanical conditions. Shaft displacement monitoring can provide useful information about rotor behavior and machine stability.
Probe temperature limits, cable specifications, and installation requirements must be checked against the actual turbine environment.
Centrifugal and other rotating compressors may require continuous shaft vibration and position monitoring. Eddy current measurement systems can provide non-contact information about shaft movement at selected bearing locations.
This information supports machinery condition assessment and maintenance planning.
Large industrial pumps and motors may experience shaft movement caused by bearing wear, imbalance, alignment problems, or changing process loads.
An appropriately configured proximity measurement system can help maintenance teams monitor relative shaft movement and identify changes that warrant inspection.
Industrial gearboxes and other rotating machines may use displacement monitoring to evaluate shaft behavior and mechanical stability.
The probe location and measurement direction should be selected according to the machine design and the condition being monitored.
Correct installation is essential for obtaining stable and repeatable measurements from an eddy current sensor.
Before installation, confirm that the PR6424 probe, extension cable, and CON021 converter are designed to operate together.
The complete model numbers and cable configuration should be checked. Using an incompatible extension cable or converter may change the measuring characteristics and result in inaccurate readings.
Verify the probe head diameter, mounting thread, insertion length, and available installation space. The supplied product description identifies a 16 mm sensor head, but the PR6424/013 model designation should be checked against the original product documentation.
The probe should be mounted securely. Excessive vibration or movement of the mounting bracket can introduce measurement errors.
The initial clearance between the probe tip and the shaft must follow the specifications for the exact measuring system.
An incorrect initial gap may reduce the usable measurement range or cause the signal to operate outside its calibrated region.
Use the manufacturer’s installation and calibration procedure rather than relying on a generic gap value.
Eddy current probes are designed for conductive targets. Their measuring characteristics depend on the electrical and magnetic properties of the target material.
For rotating machinery applications, the target material and shaft surface condition should match the requirements of the selected probe system.
Use the specified cable type and connectors. Route sensor cables away from high-current power conductors, variable frequency drive output cables, and other potential sources of electrical interference.
Observe the manufacturer’s shielding and grounding instructions. Poor cable routing or incorrect grounding can introduce noise into the measurement signal.
Confirm the converter’s power supply, terminal connections, probe compatibility, and output scaling.
The converter must be configured according to the associated probe and monitoring-system requirements. Do not assume that settings from another PR6424 model are interchangeable.
After mechanical installation and electrical connection, verify the measuring-chain response using the manufacturer’s calibration procedure.
Check the output at known probe gaps where suitable calibration equipment is available. Confirm signal stability, scaling, and monitoring-channel operation before placing the machine into normal service.
The PR6424/013-140 + CON021 assembly operates as part of a complete proximity measurement system.
| Component | Function | Compatibility Considerations |
|---|---|---|
| PR6424 proximity probe | Detects shaft-to-probe distance changes | Confirm the exact probe variant and dimensions |
| CON021 converter | Conditions the probe measurement signal | Must match the probe and required output configuration |
| Extension cable | Connects the probe to the converter | Cable type and electrical characteristics must be compatible |
| Machinery monitoring system | Receives and evaluates measurement signals | Verify input range, scaling, and channel configuration |
| DCS | Displays and processes plant operating information | Requires a compatible signal interface |
| PLC | Uses measurement information in automation logic | Confirm signal conditioning and input compatibility |
| Probe mounting bracket | Holds the sensor in the correct position | Must provide rigid and stable mechanical support |
| Rotating shaft | Provides the metallic measurement target | Target material and surface condition affect measurement |
| Power supply | Supplies the converter | Confirm the exact CON021 supply requirements |
The components listed above describe a typical measuring-chain arrangement. They are not necessarily all included in the supplied product package.
The PR6424 series includes different probe configurations. Replacement selection should be based on the complete model number rather than the series name alone.
| Alternative | Selection Considerations |
|---|---|
| Other PR6424 probe variants | Compare tip dimensions, cable length, mounting arrangement, measuring range, and temperature rating |
| PR6423 series probes | Different probe family and measuring characteristics; verify converter compatibility |
| PR6426 series probes | Designed for different measurement configurations; check the complete measuring-chain specification |
| CON021 converter | Must match the selected probe and required signal output |
| Other EPRO converter models | Confirm probe compatibility, power requirements, scaling, and output characteristics |
Before replacing an existing sensor, compare:
A probe with the same general appearance may have different electrical characteristics. Replacing only the probe or converter without checking the complete measuring chain can lead to incorrect readings.
The eddy current principle allows the probe to measure shaft movement without physical contact with the rotating surface. This avoids mechanical contact wear at the measurement point.
The system can provide ongoing measurement information for machinery condition monitoring and operational assessment.
The probe can detect changes in the distance between its sensing tip and a conductive metallic target, supporting shaft displacement and position monitoring.
The CON021 converter processes the compatible probe signal for connection to an appropriate monitoring system.
The PR6424 series is used in industrial machinery measurement applications involving turbines, compressors, pumps, motors, and other rotating equipment.
Continuous measurement trends can help maintenance teams identify changes in machinery behavior and plan inspections according to equipment condition.
It is an eddy current measurement assembly combining a PR6424 series proximity probe with a CON021 signal converter. It is used for non-contact measurement of shaft displacement and relative position in rotating machinery.
An eddy current sensor measures changes in the distance between its sensing tip and a conductive metallic target. In rotating machinery, this measurement can be used to monitor shaft displacement and vibration.
The CON021 conditions the measurement signal from a compatible EPRO proximity probe and provides an electrical output for a suitable monitoring system.
The supplied product description identifies it as a 16 mm sensor. However, available product listings describe the PR6424/013 designation as a 13 mm probe-tip version. Verify the exact probe dimensions using the nameplate or original manufacturer documentation before purchasing.
No. Eddy current measurement is non-contact. The probe is mounted with a controlled clearance from the conductive shaft surface.
It can provide relative shaft displacement measurements that are used by compatible monitoring equipment to evaluate shaft vibration.
The probe should be connected through its compatible signal converter. The converter output can then be connected to suitable monitoring or automation equipment after checking signal type, voltage range, scaling, and input requirements.
The combined model designation PR6424/013-140 + CON021 indicates a probe-and-converter configuration. Confirm the actual package contents with the supplier before ordering.
Check the full probe model, head dimensions, cable configuration, converter model, measuring range, sensitivity, mounting arrangement, and monitoring-system settings.
The supplied product listing specifies a weight of 0.32 kg. Confirm whether this represents the probe assembly alone or the complete supplied package before calculating shipping weight.
When purchasing the EPRO PR6424/013-140 + CON021 assembly, verify the complete probe and converter model numbers. Pay particular attention to the sensor head diameter because the supplied 16 mm description differs from available information for the PR6424/013 model designation.
Request clear photographs of the probe label, connector, cable, and converter identification plate. Confirm whether the quoted assembly includes the probe, converter, and any required extension cable. These details affect both installation and the total measuring-chain configuration.
For maintenance, inspect the probe mounting arrangement, cable condition, connectors, and converter terminals. Check for loose connections, damaged insulation, contamination, or mechanical movement of the mounting bracket.
Where measurement accuracy is important, follow the manufacturer’s calibration procedure and retain records of the initial gap, calibration values, converter configuration, and monitoring-channel settings.
For replacement projects, avoid mixing components from different probe configurations without confirming compatibility. The complete measuring chain should be evaluated to ensure that the replacement provides the required measurement range and output characteristics.
The EPRO PR6424/013-140 + CON021 Eddy Current Sensor is a non-contact measurement assembly designed for monitoring shaft displacement and relative movement in industrial rotating machinery. Its probe detects changes in the distance to a conductive metallic target, while the CON021 converter conditions the measurement signal for compatible monitoring equipment.
The assembly can support condition monitoring for turbines, compressors, pumps, motors, and other rotating equipment. Correct probe selection, cable matching, converter configuration, mounting, and calibration are essential for reliable measurements.
Before listing or purchasing this model, verify the discrepancy between the supplied 16 mm sensor description and the PR6424/013 model designation. Accurate identification helps ensure that the selected sensor matches the original installation and the required monitoring performance.