Product Overview: 3500/92 136188‑02 + 136180‑01 Product Name (bold): 3500/92 136188‑02 + 136180‑01 Specifications Parameter Details Dimensions (L × W × H) 241 mm × 24.4 mm × 99.1 mm Weight (……
Bently Nevada 3500/92 136188-02+136180-01 Communication Gateway Module
  • Bently Nevada
  • 3500/92 136188-02+136180-01
  • Communication Gateway Module
  • USA
  • 241 mm × 24.4 mm × 99.1 mm
  • 0.44kg
  • Xiamen, China
  • New & In Stock
  • T/T, PayPal, Western Union
  • 1 Year
  • 1-3 Working Days
  • DHL, UPS, TNT, FedEx and EMS.
  • 24-Hour Service
  • COO
  • 120

Our advantage

Bently Nevada 3500/92 136188-02+136180-01 Communication Gateway Module

Global Logistics

We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.

Bently Nevada 3500/92 136188-02+136180-01 Communication Gateway Module

Brand new and original

Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.

Bently Nevada 3500/92 136188-02+136180-01 Communication Gateway Module

24-hour service

We provide 7*24 hours service to our customers. We will be there whenever you need us.

Bently Nevada 3500/92 136188-02+136180-01 Communication Gateway Module

Price advantage

All our products are priced very favorably because we have our own warehouse and supply.


Company Information
E-mail [email protected]
Mobile +8615980777398
Whatsapp +8615980777398
WeChat 15980777398

Product Overview: 3500/92 136188‑02 + 136180‑01

Product Name (bold): 3500/92 136188‑02 + 136180‑01


Specifications

Parameter Details
Dimensions (L × W × H) 241 mm × 24.4 mm × 99.1 mm
Weight (kg) 0.44 kg
Power Supply 24 V DC ±10 %
Power Consumption ~5.6 W typical when equipped with a Modbus RS‑485 I/O module
Communication Interfaces Ethernet (TCP/IP), RS‑232, RS‑422, RS‑485
Supported Protocols Modbus TCP/IP, Modbus RTU, internal control software protocols
RS‑485 Range Up to ~1,200 m
Modbus Capacity Up to 64 I/O points, 256 registers, 32 slave devices
Operating Temperature –40 °C to +70 °C
Ingress Protection IP‑67 (dust-tight and immersion-resistant)
Mounting Form Factor Rack-mount slide-in design
Status LEDs OK, TX, RX indicators for system health and communication

Product Description

The 3500/92 136188‑02 + 136180‑01 is a communication gateway module engineered for high-reliability industrial condition-monitoring systems. Composed of a rear I/O board (136188‑02) and a front gateway board (136180‑01), it delivers both network and serial connectivity, enabling robust data flow to higher-level control and diagnostic systems.

This module supports Modbus communication over Ethernet (TCP/IP) and serial (RS‑485/422/232), bridging classic and modern system architectures. With IP‑67 protection and a temperature range from –40 °C to +70 °C, it’s built for demanding industrial environments. The compact, modular design ensures fast, secure rack deployment and maintenance.


Applications

This gateway is well suited for:

  • Real-time transmission of machinery data—like vibration, alarms, operating status—to PLCs, DCS, or SCADA platforms.

  • Industrial sites with wide-area equipment spacing, leveraging long-range serial communication.

  • Harsh operational environments such as washdown zones, dusty or exposed outdoor locations.

  • Hybrid system architectures where legacy serial and modern Ethernet networks coexist.

  • Enhancing modular condition monitoring systems with efficient data aggregation and communication.


Key Advantages

  • Hybrid connectivity: Ethernet and serial interfaces offer maximum integration flexibility.

  • Robust design: IP‑67 rating ensures reliable operation in extreme conditions.

  • Extended communication reach: RS‑485 supports up to ~1,200 m of range.

  • High I/O density: Supports numerous I/O points and registers for comprehensive data mapping.

  • Compact, modular installation: Front and rear slide-in modules simplify rack-based setup.

  • Wide temperature tolerance: Performs steadily in conditions from –40 °C to +70 °C.

  • Low power footprint: Approximately 5.6 W typical, enabling energy-efficient communication.


Series Context

Part of the 3500-series modular monitoring system, this configuration serves as the communication interface enabling data transfer from rack-based monitoring modules to supervisory systems.


Brand Context

Produced by a trusted industrial instrumentation provider renowned for robust asset protection and monitoring solutions. (Brand identity omitted as requested.)


Related / Same-Series Models

Model Dimensions Weight (kg) Interfaces Notes
3500/92 + 133323‑01 241 × 24.4 × 99.1 mm ~0.42 kg RS‑485 only Serial-only connectivity
3500/92 + 136188‑01 241 × 24.4 × 99.1 mm ~0.44 kg Ethernet + RS‑232 Older multi-interface version
3500/92 + 125736‑01 241 × 24.4 × 99.1 mm ~0.43 kg RS‑232 / RS‑422 Legacy serial support
3500/92 + 145988‑02 241 × 24.4 × 99.1 mm ~0.45 kg Modbus TCP/IP + RTU Dual-protocol communication
3500/92 (Main only) 241 × 24.4 × 99.1 mm ~0.30 kg None (core processor unit) Requires separate I/O module

Popular Models from the Same Brand

Model Dimensions Weight (kg) Functionality Typical Application
3500/60M 170 × 120 × 55 mm ~1.04 kg Shaft clearance + vibration monitor Turbine and rotating equipment monitoring
3500/90M‑W 180 × 125 × 60 mm ~1.08 kg Wireless communication module Remote or inaccessible rack environments
3300/12B 200 × 120 × 60 mm ~1.20 kg Bearing vibration alert module Immediate fault detection
3500/30M 170 × 120 × 55 mm ~1.02 kg Dual-channel vibration monitor General machine health monitoring
3300/21 190 × 120 × 60 mm ~1.10 kg Speed and phase interface Sampling rotating speed for turbines


FAQ (10 Q&A)

  1. Q: How is 3500/92 136188‑02 + 136180‑01 installed?
    A: Slide the I/O unit into the back of the rack and the gateway board into the front; latch them securely. Tool-free, fast, and reliable.

  2. Q: Can it communicate via both Ethernet and RS‑485 simultaneously?
    A: Yes, it handles Modbus over both interfaces concurrently—ideal for hybrid systems.

  3. Q: What environmental conditions can it tolerate?
    A: It’s made for harsh areas—IP‑67 casing keeps out dust and moisture; works from –40 °C to +70 °C.

  4. Q: How long is the RS‑485 communication range?
    A: Up to roughly 1,200 m, depending on wiring and network setup.

  5. Q: How much power does it require?
    A: Typically about 5.6 W under normal operation.

  6. Q: How many devices can it manage via Modbus?
    A: Supports up to 32 slave devices, 64 I/O points, and 256 registers.

  7. Q: How do I confirm it’s functioning?
    A: Front LEDs marked OK, TX, and RX indicate module status and communication health.

  8. Q: Is it backward compatible with legacy control systems?
    A: Yes, it supports RS‑232, RS‑422, RS‑485, and Ethernet Modbus, bridging old and new networks.

  9. Q: Can firmware updates be applied easily?
    A: Updates are typically executed over Ethernet, following a straightforward, controlled process.

  10. Q: Can it be removed or replaced during operation?
    A: Yes—its design supports hot-swapping without shutting down adjacent modules in the rack.