• Allen Bradley 22C-D017N103 Power Flex 400 AC Drive
  • Allen Bradley 22C-D017N103 Power Flex 400 AC Drive
  • Allen Bradley 22C-D017N103 Power Flex 400 AC Drive
  • Allen Bradley 22C-D017N103 Power Flex 400 AC Drive
Product Overview The Allen-Bradley 22C-D017N103 PowerFlex 400 AC Drive is an adjustable-frequency drive designed primarily for industrial fan and pump applications. Manufactured by Rockwell Automation, ……
Allen Bradley 22C-D017N103 Power Flex 400 AC Drive
  • Allen Bradley
  • 22C-D017N103
  • Power Flex 400 AC Drive
  • USA
  • 130 x 260 x 180 mm
  • 4.33 kg
  • Xiamen, China
  • New & In Stock
  • T/T, PayPal, Western Union
  • 1 Year
  • 1-3 Working Days
  • DHL, UPS, TNT, FedEx and EMS.
  • 24-Hour Service
  • COO
  • 4

Our advantage

Allen Bradley 22C-D017N103 Power Flex 400 AC Drive

Global Logistics

We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.

Allen Bradley 22C-D017N103 Power Flex 400 AC Drive

Brand new and original

Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.

Allen Bradley 22C-D017N103 Power Flex 400 AC Drive

24-hour service

We provide 7*24 hours service to our customers. We will be there whenever you need us.

Allen Bradley 22C-D017N103 Power Flex 400 AC Drive

Price advantage

All our products are priced very favorably because we have our own warehouse and supply.


Company Information
E-mail [email protected]
Mobile +8615980777398
Whatsapp +8615980777398
WeChat 15980777398

Product Overview

The Allen-Bradley 22C-D017N103 PowerFlex 400 AC Drive is an adjustable-frequency drive designed primarily for industrial fan and pump applications. Manufactured by Rockwell Automation, this drive belongs to the PowerFlex 400 series and provides variable-speed control for compatible three-phase AC motors.

Variable frequency drives regulate motor speed by adjusting the frequency and voltage supplied to the motor. This allows industrial equipment to operate according to actual process requirements instead of running continuously at a fixed speed. In fan and pump systems, adjustable-speed operation can help regulate airflow and fluid delivery while reducing unnecessary mechanical and electrical stress.

The 22C-D017N103 is a 480 V AC three-phase model with a rated output current of 17 A and a power rating of 7.5 kW (10 HP). It uses a Frame C design and an IP20 open-type enclosure configuration. The drive is equipped with a fixed keypad for local operation and an RS-485 communication interface for integration with compatible industrial control systems.

The PowerFlex 400 series is particularly suitable for applications involving centrifugal fans and pumps. Its motor-control functions support adjustable operating speeds, process regulation, and integration with automation equipment.

This catalog number identifies a specific hardware configuration. The 22C-D017N103 does not include a braking IGBT. Therefore, users should distinguish it from other PowerFlex 400 models with different braking or communication options when selecting spare parts or planning equipment replacements.

Technical Specifications

Parameter Specification
Brand Allen-Bradley
Manufacturer Rockwell Automation
Model 22C-D017N103
Product Series PowerFlex 400
Product Type AC Drive / Variable Frequency Drive
Application Fan and Pump Control
Input Voltage 480 V AC
Input Phase Three-phase
Input Voltage Range 342–528 V AC
Supply Frequency 50/60 Hz
Rated Output Current 17 A
Rated Motor Power 7.5 kW
Horsepower Rating 10 HP
Frame Size Frame C
Enclosure Rating IP20 / NEMA UL Open Type
Control Method V/Hz, slip compensation, process PID
Human Interface Fixed Keypad
Communication Interface RS-485
Braking IGBT Not included
Mounting Type Panel Mount
Dimensions Provided 130 × 260 × 180 mm
Weight Provided 4.33 kg
Product Lifecycle Active, according to manufacturer listing
Typical Applications Industrial Fans, Pumps, HVAC and Fluid Handling

Note: Dimensions and weight are supplied product-listing values. Confirm the actual unit and mounting drawing before installation.

Function and Working Principle

The PowerFlex 400 operates by converting incoming AC electrical power into a controlled output for a three-phase motor. By adjusting output frequency and voltage, the drive regulates motor speed according to the application requirements.

1. Variable Frequency Motor Control

The operating speed of an AC motor is related to the frequency of its electrical supply. The drive changes the output frequency to control the motor’s speed.

In a fan application, the motor may operate at different speeds depending on the required airflow. In a pump application, motor speed can be adjusted according to the required fluid flow or pressure.

This approach allows the motor to respond to changing process conditions rather than operating continuously at maximum speed.

2. V/Hz Control

The PowerFlex 400 supports V/Hz control, which maintains an appropriate relationship between output voltage and frequency over the operating range.

This control method is commonly used for general-purpose fan and pump applications. It provides a practical approach to controlling motor speed without requiring a complex feedback arrangement.

The correct motor parameters and operating limits should be configured during commissioning to achieve stable performance.

3. Slip Compensation

Motor slip refers to the difference between the synchronous magnetic field speed and the actual rotor speed in an induction motor.

The drive’s slip compensation function helps maintain more consistent motor speed when the mechanical load changes. This can be useful in applications where airflow or fluid delivery needs to remain relatively stable under varying operating conditions.

4. Process PID Control

The PowerFlex 400 includes process PID functionality for applications that require automatic regulation of a process variable.

For example, a pressure sensor can provide feedback to a pump-control system. The drive can use the process feedback and programmed setpoint to adjust motor speed.

Typical process variables include:

  • Pump discharge pressure.
  • Fluid flow rate.
  • Air duct pressure.
  • Ventilation system pressure.
  • Other suitable process signals.

The actual control arrangement depends on the connected sensors, wiring, and parameter configuration.

5. RS-485 Communication

The integrated RS-485 interface supports communication with compatible industrial control equipment.

Depending on the selected communication protocol and system configuration, a PLC or supervisory system can exchange operating commands and drive information with the inverter.

This provides an alternative to using only hardwired control signals and can simplify integration in suitable automation architectures.

Role in Industrial Control Systems

The 22C-D017N103 is designed to operate as part of an industrial motor-control system. It connects the electrical supply to a compatible AC motor and regulates motor operation based on local settings or external control commands.

PLC Integration

A programmable logic controller can coordinate the drive with sensors, valves, contactors, and other equipment.

For example, a PLC may monitor a pressure transmitter and send an operating reference to the PowerFlex 400. The drive then adjusts the pump motor speed according to the control strategy.

The built-in RS-485 interface can support communication with compatible control devices. Communication settings, protocol compatibility, and network wiring must be verified before integration.

HMI and Operator Control

The fixed keypad allows operators or maintenance personnel to access local drive functions and settings.

In a larger automation system, an HMI can provide centralized monitoring and control through the PLC or a compatible communication arrangement.

Operators may use the system to monitor motor speed, operating conditions, alarms, and process information.

Process Monitoring

In fan and pump systems, maintaining the required process condition is often more important than maintaining a fixed motor speed.

The drive’s process PID functionality can help regulate variables such as pressure or flow when suitable feedback signals are available.

This makes the PowerFlex 400 relevant to automated HVAC systems, water treatment equipment, industrial circulation systems, and other process installations.

Industrial Applications

The PowerFlex 400 series was developed specifically for fan and pump applications. The 22C-D017N103 provides a 7.5 kW rating and 17 A output current for appropriately sized motors.

1. Industrial Ventilation Systems

Industrial ventilation systems use fans to circulate air, remove heat, and maintain suitable working conditions.

The PowerFlex 400 can regulate fan speed according to airflow requirements. In systems with changing ventilation demand, variable-speed control can reduce unnecessary operation at maximum speed.

Typical applications include factory ventilation, equipment cooling, and industrial air circulation.

2. HVAC Systems

Heating, ventilation, and air-conditioning installations frequently use fans and pumps to move air and fluids.

The drive can support adjustable-speed operation in compatible HVAC equipment. Its process PID function may be used in suitable pressure or flow-control arrangements.

System designers should ensure that motor ratings, airflow requirements, and operating conditions are compatible with the drive.

3. Water Supply and Pumping Stations

Water supply systems often experience changes in demand throughout the day.

A variable frequency drive can adjust pump speed according to system pressure or flow requirements. This can help reduce pressure fluctuations and unnecessary mechanical stress.

The PowerFlex 400 can be considered for appropriately rated industrial pumping applications.

4. Industrial Cooling Systems

Cooling systems use fans and pumps to transfer heat away from machinery and process equipment.

The drive can regulate the speed of compatible cooling fans or pump motors according to process demand.

Applications may include industrial heat exchangers, cooling water circulation, and equipment cooling systems.

5. Manufacturing Facilities

Manufacturing plants often use auxiliary fan and pump systems to support production equipment.

The 22C-D017N103 can be incorporated into suitable motor-control installations where adjustable speed and process regulation are required.

Its RS-485 interface can also support integration with compatible monitoring and automation systems.

Installation and System Integration

Correct installation is essential for electrical safety, stable operation, and long-term equipment reliability.

1. Verify the Electrical Supply

The 22C-D017N103 is designed for a 480 V AC three-phase supply. Before installation, verify the incoming voltage, supply frequency, and available electrical capacity.

The motor’s nameplate current must also be checked. The drive’s rated output current is 17 A, and the connected motor must remain within the applicable drive ratings.

Do not select a drive based only on motor horsepower. Output current, load characteristics, operating duty, and environmental conditions are also important.

2. Confirm Panel Mounting Requirements

The supplied dimensions are 130 × 260 × 180 mm. Confirm the manufacturer’s mechanical drawing and actual unit dimensions before preparing the control cabinet.

Provide sufficient clearance for ventilation, wiring, and maintenance access.

The IP20 open-type enclosure is intended for installation within an appropriate electrical enclosure. It does not provide protection against direct water exposure or unrestricted dust ingress.

3. Power and Motor Wiring

Power wiring should be installed according to the manufacturer’s instructions and applicable electrical regulations.

Important installation considerations include:

  • Correct incoming supply connections.
  • Proper motor terminal connections.
  • Suitable conductor sizing.
  • Protective grounding.
  • Appropriate upstream circuit protection.
  • Separation of power and sensitive control wiring.

Always isolate the power supply and verify that hazardous voltage has been removed before working on the drive.

4. Configure Motor Parameters

During commissioning, enter the motor nameplate information and configure the operating parameters.

Relevant settings may include:

  • Motor rated voltage.
  • Motor rated current.
  • Motor frequency.
  • Acceleration time.
  • Deceleration time.
  • Minimum and maximum operating frequency.
  • Start and stop command sources.
  • Speed reference source.
  • PID control parameters, where applicable.

Incorrect settings can cause poor motor performance, unnecessary trips, or unsuitable operating conditions.

5. Configure PID Control

For applications using process regulation, connect the appropriate feedback signal and configure the PID setpoint and control parameters.

For example, a pump system may use a pressure transmitter to provide feedback. The drive can then adjust motor speed to maintain the desired pressure.

PID tuning should be performed according to the system’s response characteristics. Incorrect tuning can cause unstable operation or excessive speed changes.

6. Configure RS-485 Communication

When the drive is integrated into a PLC or supervisory system through RS-485, configure the communication parameters according to the selected protocol.

Check:

  • Communication protocol.
  • Network address.
  • Baud rate.
  • Data format.
  • Cable connections.
  • Network termination requirements.
  • PLC communication settings.

Communication should be tested before the system is placed into normal production operation.

Compatible System Components

The 22C-D017N103 is normally integrated with motor, electrical protection, control, and monitoring equipment.

Component Function Integration Considerations
Three-phase AC motor Drives the fan or pump Verify voltage, current, horsepower, and operating frequency
PLC Coordinates motor operation Confirm available I/O and RS-485 communication compatibility
HMI Provides operator monitoring and control Can communicate through the PLC or a suitable network arrangement
Pressure transmitter Measures system pressure Useful for suitable pump PID applications
Flow transmitter Measures fluid flow Can provide process feedback when supported by the control design
Circuit breaker Provides upstream electrical protection Select according to manufacturer recommendations
Motor isolator Supports electrical isolation Install according to applicable safety requirements
RS-485 communication cable Connects compatible control equipment Observe wiring, grounding, and network requirements
Control cabinet Houses the drive and related equipment Provide sufficient cooling and environmental protection

These components are examples of equipment used in a complete installation. They are not necessarily supplied with the drive.

Alternative Models and Replacement Considerations

When replacing the 22C-D017N103, the complete electrical and functional configuration must be checked.

Alternative Model Description Replacement Considerations
22C-D012N103 PowerFlex 400, 5.5 kW, 12 A Lower current and power rating; not a direct substitute for every application
22C-D017N103 PowerFlex 400, 7.5 kW, 17 A Original model
22C-D022N103 PowerFlex 400, 11 kW, 22 A Higher-rated model; verify motor and protection requirements
PowerFlex 525 Compact AC drive family May suit selected applications but requires compatibility assessment
PowerFlex 753 Industrial AC drive family May be considered for more advanced applications and system upgrades

Before selecting an alternative, compare:

  • Input voltage and phase.
  • Output current.
  • Motor power rating.
  • Overload capability.
  • Control method.
  • Communication interface.
  • Enclosure rating.
  • Mounting dimensions.
  • PID and process-control requirements.
  • PLC and HMI integration.
  • Commissioning and parameter requirements.

A higher-rated drive is not automatically a suitable replacement. Differences in control terminals, communication settings, and motor-control functions may require engineering changes.

Key Advantages

Designed for Fan and Pump Applications

The PowerFlex 400 series is specifically intended for fan and pump control, making it suitable for many industrial ventilation and fluid-handling installations.

7.5 kW Motor Capacity

The 7.5 kW (10 HP) rating and 17 A output current provide motor-control capability for appropriately sized industrial equipment.

Process PID Functionality

Integrated PID functionality supports automatic process regulation in applications using suitable feedback signals.

Built-in RS-485 Interface

The communication interface supports integration with compatible industrial control equipment and monitoring systems.

Fixed Keypad Operation

The fixed keypad provides local access to drive operation and parameter configuration.

Adjustable Motor Speed

Variable-frequency operation allows motor speed to respond to changing airflow, pressure, or fluid-flow requirements.

Active Product Lifecycle Status

Rockwell Automation currently identifies this catalog number as Active in its product listing, which is useful information for procurement and maintenance planning.

Technical FAQs

1. What is the Allen-Bradley 22C-D017N103?

It is a PowerFlex 400 adjustable-frequency AC drive designed for industrial fan and pump applications. It provides a 7.5 kW (10 HP) rating with 17 A output current.

2. What input voltage does this drive require?

The drive is designed for a 480 V AC three-phase supply. The published input voltage range is approximately 342–528 V AC.

3. What is the output current?

The rated output current is 17 A.

4. Does the 22C-D017N103 have a built-in keypad?

Yes. This configuration includes a fixed keypad for local operation and parameter access.

5. Does it support RS-485 communication?

Yes. The model includes an RS-485 communication interface for compatible industrial control systems.

6. Does this model include a braking IGBT?

No. The manufacturer’s product description identifies this model as a configuration without a braking IGBT.

7. Can it be used for water pumps?

Yes, provided the pump motor’s voltage, current, power, and operating requirements are within the drive’s ratings. The process PID function can also support suitable pressure or flow regulation applications.

8. Can it control industrial fans?

Yes. Fan control is one of the primary application areas of the PowerFlex 400 series. Adjustable-speed operation can help match fan performance to ventilation requirements.

9. Is the 22C-D017N103 still active?

Rockwell Automation currently lists the model with an Active lifecycle status. Buyers should nevertheless confirm current stock and delivery availability with their supplier.

10. What should be checked before purchasing?

Verify the complete catalog number, input voltage, output current, power rating, keypad configuration, RS-485 interface, enclosure type, and physical condition. For replacement applications, compare the original drive’s parameters and wiring before installation.

Procurement and Maintenance Recommendations

When purchasing the Allen-Bradley 22C-D017N103, verify the complete catalog number rather than relying only on the PowerFlex 400 series name. The catalog number identifies the drive’s voltage class, output rating, frame size, and configuration.

For new or surplus equipment, check the product label, enclosure condition, keypad, terminal blocks, cooling fan, and available test records. Confirm whether the unit is supplied with any accessories and whether the product has been stored under suitable environmental conditions.

For maintenance, periodically inspect the drive’s ventilation openings, cooling fan, electrical terminals, grounding connections, and control wiring. Dust accumulation and restricted airflow can contribute to excessive operating temperatures.

Keep a record of motor parameters, communication settings, PID values, and other commissioning information. A parameter backup can simplify recovery after maintenance or equipment replacement.

When replacing an existing drive, compare the motor ratings, communication settings, control wiring, and application requirements. Even when the replacement belongs to the same PowerFlex family, configuration differences should be reviewed before commissioning.

Conclusion

The Allen-Bradley 22C-D017N103 PowerFlex 400 AC Drive is a 480 V AC three-phase variable frequency drive designed primarily for industrial fan and pump applications. With a rated output current of 17 A and a motor power rating of 7.5 kW (10 HP), it provides adjustable-speed control for compatible industrial motors.

Its fixed keypad, RS-485 communication interface, and process PID functionality support local operation and integration into suitable automation systems. The model does not include a braking IGBT, which should be considered when evaluating its configuration and replacement compatibility.

For industrial procurement, maintenance, and automation projects, verifying the complete catalog number and electrical specifications is essential to ensure reliable motor control and correct system integration.



Related Products

Get the latest price? We will reply as soon as possible (within 12 hours)

No:77501