Our advantage
Global Logistics
We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.
Brand new and original
Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.
24-hour service
We provide 7*24 hours service to our customers. We will be there whenever you need us.
Price advantage
All our products are priced very favorably because we have our own warehouse and supply.
| Company Information | |||
| [email protected] | |||
| Mobile | +8615980777398 | ||
| +8615980777398 | |||
| 15980777398 |

The Allen-Bradley 20DB260A0EYNANANE is a high-power AC drive in the PowerFlex 700S series, developed for industrial motor control applications that require precise speed and torque regulation. It uses Phase II control technology and supports three-phase AC input, making it suitable for demanding machinery and process installations.
With a rated output current of 260 A under normal-duty conditions, this Frame 6 drive is designed for large motor-driven equipment. Its control capabilities include field-oriented motor control, programmable acceleration and deceleration, electronic motor overload protection, and configurable operating limits.
The PowerFlex 700S platform is designed for applications where motor performance, dynamic response, and integration with industrial automation systems are important. It can be used in manufacturing plants, material handling systems, process equipment, and other installations involving high-power motors.
The 20DB260A0EYNANANE is a 240V-class, three-phase drive. It includes a brake IGBT, an EMC filter and common-mode choke, and Phase II control with an expanded cassette. It does not include an internal braking resistor or an internal communication module. These configuration details are important when selecting a replacement or planning a drive installation.
| Parameter | Specification |
|---|---|
| Brand | Allen-Bradley |
| Model | 20DB260A0EYNANANE |
| Product Series | PowerFlex 700S |
| Product Type | AC Drive |
| Control Version | Phase II |
| Input Voltage | 240V AC class |
| Input Phases | Three-phase |
| Input Frequency | 60 Hz |
| Nominal Motor Voltage | 230V |
| Continuous Output Current | 260 A (Normal Duty) |
| Heavy-Duty Power Rating | 75 HP |
| Normal-Duty Power Rating | 100 HP |
| Frame Size | Frame 6 |
| Enclosure Rating | IP20 / NEMA/UL Type 1 |
| Brake IGBT | Installed |
| Internal Brake Resistor | Not included |
| EMC Filter | Included, with common-mode choke |
| Internal Communication Module | Not included |
| Analog Inputs | 3 |
| Analog Outputs | 2 |
| Digital Inputs | 6 |
| Digital Outputs | 2 |
| Control Method | Field-oriented motor control |
| Dimensions (Provided Data) | 453.8 × 976.3 × 275.5 mm |
| Weight | 71.44 kg |
Dimension clarification: The supplied dimensions are retained above for product listing purposes. Rockwell Automation’s published mechanical data for this catalog number gives approximately 435.8 mm width × 850 mm height × 275.5 mm depth, with a drive weight of 71.44 kg. Confirm the actual unit and dimension drawing before planning cabinet space or installation.
The PowerFlex 700S uses Phase II control technology to support advanced motor-control applications. Its control architecture is designed to provide accurate regulation of motor speed and torque.
The drive supports field-oriented control for induction motors and brushless motor applications. Depending on the selected control configuration, operation can use feedback devices or operate without speed feedback.
This flexibility makes the PowerFlex 700S suitable for machinery where conventional variable-speed operation is not sufficient and more controlled motor response is required.
The 20DB260A0EYNANANE has a continuous output current rating of 260 A under normal-duty conditions. Its published ratings also identify a 100 HP normal-duty rating and a 75 HP heavy-duty rating.
The drive provides different overload capabilities according to its operating duty. Under the documented heavy-duty rating, it supports 110% overload for up to one minute and 150% overload for up to three seconds.
Correct motor selection requires consideration of the actual motor nameplate, load characteristics, operating environment, and duty classification. The drive’s current rating should not be treated as a substitute for application-specific sizing.
Acceleration and deceleration times can be programmed independently. The documented adjustment range is 0 to 6553.5 seconds, in 0.1-second increments.
This feature allows the drive to adapt motor starting and stopping behavior to different machine requirements.
For example, a conveyor system may require a controlled acceleration profile to reduce mechanical stress, while a process machine may need a carefully adjusted deceleration period to avoid disturbing the production sequence.
The drive incorporates electronic motor overload protection and multiple protective monitoring functions.
Depending on the configured application and protection settings, these functions help monitor operating conditions such as:
These functions contribute to equipment protection, but they do not eliminate the need for appropriate external circuit protection, grounding, and installation practices.
The 20DB260A0EYNANANE includes a brake IGBT but does not have an internal braking resistor.
The brake IGBT provides the switching capability for a compatible external braking arrangement. Where an application requires dynamic braking, the braking resistor and associated wiring must be selected according to the manufacturer’s recommendations.
The drive also supports programmable motoring and regenerative power limits. These settings can be relevant to applications involving frequent acceleration, deceleration, or changing load conditions.
Large conveyor systems often operate under changing load conditions. The PowerFlex 700S can regulate motor speed and torque to support controlled material movement.
Its programmable acceleration and deceleration functions are useful where smooth starts and stops help reduce mechanical stress on belts, couplings, and driven equipment.
Manufacturing and process facilities frequently use high-power motors to operate mixers, pumps, compressors, and other production machinery.
The 20DB260A0EYNANANE can provide variable-speed motor control in installations where the drive’s voltage and current ratings match the motor and application requirements.
In industrial pumping applications, variable-frequency drives can adjust motor speed according to process demand. This can help operators manage flow and pressure without relying entirely on mechanical throttling.
The drive’s control functions can be incorporated into a larger automation system, subject to the selected I/O and communication configuration.
Large industrial fans may require variable-speed operation to respond to changing ventilation or process requirements.
The PowerFlex 700S can regulate motor speed and support controlled acceleration and deceleration. Proper drive sizing should account for fan load characteristics and operating conditions.
The drive’s high-current rating and advanced control functions make it suitable for compatible heavy industrial machinery. Applications may include production lines, material processing equipment, and other large motor-driven systems.
Actual suitability depends on the motor rating, load profile, control requirements, and environmental conditions.
The 20DB260A0EYNANANE is a Frame 6 drive. Its installation requires suitable electrical infrastructure, mechanical support, ventilation, and protective equipment.
1. Verify the input power supply
Confirm that the available supply matches the drive’s 240V-class, three-phase input requirements. Check the supply voltage, frequency, phase configuration, and protective-device ratings before connecting the equipment.
2. Confirm motor compatibility
Check the motor nameplate against the drive’s output voltage, current, and power ratings. The normal-duty and heavy-duty ratings are different and should be selected according to the actual load.
3. Plan cabinet space and ventilation
The drive requires adequate installation clearance and airflow. Confirm its actual dimensions using the manufacturer’s dimension drawing rather than relying exclusively on third-party listing measurements.
4. Select suitable braking components
Because the drive includes a brake IGBT but no internal braking resistor, applications requiring dynamic braking need a compatible external resistor arrangement. Follow the manufacturer’s selection and wiring instructions.
5. Configure control and feedback
Set the motor-control mode, operating limits, acceleration and deceleration times, and relevant feedback parameters according to the application. If encoder feedback is required, verify the encoder type and electrical interface.
6. Integrate external I/O and communications
The catalog configuration lists three analog inputs, two analog outputs, six digital inputs, and two digital outputs. It does not include an internal communication module. Any required network interface must be evaluated separately.
7. Commission and test the drive
After installation, verify the wiring, motor parameters, protection settings, and control signals. Conduct commissioning tests under controlled conditions before returning the equipment to full production.
| Problem | Possible Cause | Recommended Action |
|---|---|---|
| Drive fails to start | Incorrect start command or control configuration | Check control inputs, operating mode, and drive status |
| Motor does not reach the required speed | Incorrect speed reference or motor parameters | Review the reference source and motor configuration |
| Overcurrent fault | Excessive load, acceleration time too short, or motor issue | Inspect the mechanical load and adjust settings where appropriate |
| DC bus overvoltage | Excessive regenerative energy during deceleration | Review deceleration settings and braking arrangements |
| Drive overheating | Restricted airflow, excessive ambient temperature, or cooling fan problem | Inspect ventilation paths and cooling components |
| Motor overload fault | Motor load exceeds the configured operating limits | Check motor current, load conditions, and overload settings |
| Unstable motor speed | Incorrect feedback configuration or signal interference | Inspect encoder wiring, feedback settings, and signal connections |
| Analog reference is incorrect | Wiring or scaling configuration problem | Verify analog signal connections and parameter scaling |
| Communication unavailable | No internal communication module or incorrect external interface | Confirm the installed communication hardware and network configuration |
Preventive maintenance should include inspection of cooling fans, heat sinks, electrical connections, grounding, and cabinet ventilation. Dust accumulation and loose power connections can contribute to overheating and unreliable operation.
Before opening the drive enclosure, disconnect the power supply and follow the manufacturer’s DC bus discharge and voltage-verification procedures. Maintenance should be performed by qualified personnel.
1. What is the Allen-Bradley 20DB260A0EYNANANE?
It is a PowerFlex 700S Phase II AC drive designed for high-power industrial motor control applications.
2. What input voltage does this drive use?
It belongs to the 240V-class, three-phase input family. The documented input voltage range is 200–240V AC, with a nominal 240V rating.
3. What is its continuous output current?
The published normal-duty continuous output current is 260 A.
4. What are its motor power ratings?
The catalog configuration is rated at 100 HP for normal-duty applications and 75 HP for heavy-duty applications.
5. Does the drive support encoder feedback?
The PowerFlex 700S control platform supports motor-control configurations with and without feedback devices. The encoder type and wiring must match the selected configuration.
6. Does the 20DB260A0EYNANANE include a braking resistor?
No. It includes a brake IGBT but does not have an internal braking resistor. A compatible external braking arrangement is required when dynamic braking is needed.
7. What I/O points are available?
The published configuration lists three analog inputs, two analog outputs, six digital inputs, and two digital outputs.
8. Does this model include an internal communication module?
No. The catalog configuration specifies that an internal communication module is not included. Additional communication hardware may be needed depending on the control system.
9. What is the difference between normal-duty and heavy-duty ratings?
Normal-duty and heavy-duty ratings reflect different load and overload requirements. The 20DB260A0EYNANANE has a 100 HP normal-duty rating and a 75 HP heavy-duty rating. The correct selection depends on the motor and application load profile.
10. What should buyers verify before purchasing this drive?
Buyers should confirm the complete catalog number, input voltage, output current, control configuration, brake IGBT arrangement, communication requirements, enclosure condition, and physical dimensions. For used or surplus equipment, checking the nameplate and testing the unit’s condition are also important.
The Allen-Bradley 20DB260A0EYNANANE PowerFlex 700S AC Drive is a high-current variable-frequency drive designed for demanding industrial motor-control applications. Its Phase II control platform, 260 A normal-duty output rating, programmable operating functions, and integrated brake IGBT make it suitable for compatible high-power machinery.
When selecting this drive for a new installation or as a replacement unit, it is important to verify the electrical ratings, motor requirements, braking arrangement, control configuration, and physical installation dimensions. Careful model verification helps ensure that the drive matches the requirements of the existing industrial automation system.