Product Overview Accurate temperature measurement is fundamental for process control and equipment protection in industrial environments. The Honeywell TC-IXR061 (96978377 A01) RTD Analog Input Module i……
Honeywell TC-IXR061 96978377 A01 RTD Analog Input Module
  • Honeywell
  • TC-IXR061 96978377 A01 RTD Analog Input Module
  • RTD Analog Input Module
  • USA
  • 180 x 120 x 30 mm
  • 0.281 kg
  • Xiamen, China
  • New & In Stock
  • T/T, PayPal, Western Union
  • 1 Year
  • 1-3 Working Days
  • DHL, UPS, TNT, FedEx and EMS.
  • 24-Hour Service
  • COO
  • 2

Our advantage

Honeywell TC-IXR061 96978377 A01 RTD Analog Input Module

Global Logistics

We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.

Honeywell TC-IXR061 96978377 A01 RTD Analog Input Module

Brand new and original

Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.

Honeywell TC-IXR061 96978377 A01 RTD Analog Input Module

24-hour service

We provide 7*24 hours service to our customers. We will be there whenever you need us.

Honeywell TC-IXR061 96978377 A01 RTD Analog Input Module

Price advantage

All our products are priced very favorably because we have our own warehouse and supply.


Company Information
E-mail [email protected]
Mobile +8615980777398
Whatsapp +8615980777398
WeChat 15980777398

Product Overview

Accurate temperature measurement is fundamental for process control and equipment protection in industrial environments. The Honeywell TC-IXR061 (96978377 A01) RTD Analog Input Module is designed to provide precise temperature data acquisition from RTD (Resistance Temperature Detector) sensors within Honeywell’s Experion LS control system.

This module enables stable and high-accuracy signal processing, making it ideal for applications where precise thermal monitoring is required. With reliable performance and seamless integration, it plays a key role in maintaining system efficiency and operational safety.


Technical Specifications

Parameter Details
Manufacturer Honeywell
Model TC-IXR061
Part Number 96978377 A01
Product Type RTD Analog Input Module
Function RTD temperature signal acquisition
Input Type RTD (Resistance Temperature Detector)
System Compatibility Experion LS
Dimensions 180 × 120 × 30 mm
Weight 0.281 kg
Installation Rack-mounted / control cabinet
Application High-precision temperature monitoring
Environment Industrial-grade
Data Processing Real-time analog-to-digital conversion
Measurement Accuracy High stability and precision
Reliability Designed for continuous operation

Function and Working Principle

The TC-IXR061 RTD Analog Input Module collects resistance-based temperature signals from RTD sensors and converts them into digital data for system processing.

Its operation includes:

  • Receiving resistance signals from RTD sensors
  • Converting resistance values into temperature readings
  • Performing high-precision analog-to-digital conversion
  • Transmitting processed data to the Experion LS control system

This ensures accurate and stable temperature monitoring, even in applications requiring tight control tolerances.


Role in Industrial Control Systems

The TC-IXR061 module plays an essential role in temperature monitoring within the Experion LS architecture, supporting:

  • Continuous temperature measurement for critical processes
  • Integration with control systems and automation logic
  • Feedback loops for precise thermal regulation
  • System-wide monitoring and diagnostics

It helps maintain stable operation and ensures consistent product quality in industrial processes.


Industrial Applications

The Honeywell TC-IXR061 module is widely used in:

  • Distributed Control Systems (DCS)
  • Power generation facilities
  • Oil and gas processing plants
  • Chemical and pharmaceutical industries
  • Manufacturing and automation systems
  • Precision temperature control environments

Its accuracy and stability make it ideal for applications where RTD sensors are preferred over thermocouples.


Installation and System Integration

Proper installation is critical for reliable performance:

  • Mounted in Experion LS racks or control cabinets
  • Connected to RTD sensors with appropriate wiring configurations
  • Integrated via system backplane communication
  • Configured using control system software
  • Requires proper grounding and shielding to reduce noise

Correct installation ensures accurate measurements and long-term reliability.


Compatible System Components

The TC-IXR061 typically operates with:

  • Honeywell Experion LS controllers
  • I/O interface modules
  • RTD temperature sensors
  • Communication backplanes
  • Monitoring and control software

Together, these components form a complete and efficient temperature monitoring system.


Recommended Alternative Models

Model Type Key Feature Application
TC-IXL061 Thermocouple Input Module Supports thermocouple sensors General temperature monitoring
TC-IXL062 Thermocouple Input Module Higher channel capacity Complex systems
TC-IAIH01 Analog Input Module Multi-signal input capability Flexible applications
Experion LS Universal Input Module Multi-input Module Supports multiple sensor types Custom systems
Industrial RTD Input Module Generic Module Cost-effective solution Standard automation

Key Advantages

  • High-precision RTD signal acquisition
  • Stable and reliable temperature measurement
  • Seamless integration with Experion LS systems
  • Compact and lightweight design
  • Suitable for demanding industrial environments
  • Supports continuous and accurate operation

Technical FAQs

What is the primary function of the TC-IXR061 module?
It acquires temperature data from RTD sensors and converts it into digital signals for monitoring and control.

Where is this module commonly used?
It is used in industrial systems requiring high-precision temperature measurement and stability.

Why choose RTD input over thermocouple?
RTD sensors typically provide higher accuracy and stability, making them suitable for precision applications.


Conclusion

The Honeywell TC-IXR061 (96978377 A01) RTD Analog Input Module is a reliable and high-precision solution for industrial temperature monitoring. Its ability to accurately process RTD signals ensures stable system performance and improved process control.

For engineers and system integrators, this module offers a dependable approach to achieving accurate temperature measurement in complex and demanding industrial environments.