Product Name: ABB 5SGY3545L0014
Part Number: 3BHB006485R0001
Brand: ABB
Series: ABB S500 Series
Product Type: Residual Current Circuit Breaker (RCCB)
Category: Electrical Protection Equipment
The ABB 5SGY3545L0014 is a Residual Current Circuit Breaker (RCCB) from the ABB S500 Series. Designed to provide effective protection against electrical shocks and fires caused by leakage currents, this device is an essential safety feature in both residential and industrial electrical systems. It helps to detect imbalances in the electrical current between the live (phase) and neutral wires, disconnecting the circuit in the event of leakage, thus minimizing the risk of electrical hazards.
This particular model has a rated current of 45A and is capable of detecting residual currents in excess of 30mA, offering protection for people and equipment. It also comes with instantaneous trip functionality, ensuring fast disconnection in case of leakage to prevent injury or damage.
The ABB 5SGY3545L0014 is highly reliable and designed for easy installation in distribution boards, meeting international electrical safety standards. It provides peace of mind by safeguarding both individuals and electrical equipment from the risks associated with earth leakage.
The ABB 5SGY3545L0014 RCCB is suitable for use in various types of installations where electrical safety is critical. Its common applications include:
Residential Buildings:
Protects household circuits and individuals from electrical shocks due to earth leakage, particularly in areas where electrical safety is paramount (e.g., bathrooms, kitchens).
Commercial and Industrial Installations:
Ensures safety in commercial buildings, factories, and industrial installations, where large electrical equipment is used and the risk of electrical leakage is higher.
Data Centers and IT Infrastructure:
Essential for protecting sensitive equipment such as servers, IT infrastructure, and electrical panels from leakage currents, ensuring uninterrupted operations.
Public Infrastructure:
Used in the protection of electrical systems in schools, hospitals, and other public facilities where the safety of people is a priority.
Solar Power Systems:
Can be integrated into solar power installations to ensure that the system is protected from any potential leakage of current, safeguarding both the system and people.
The ABB 5SGY3545L0014 is integral in providing safety and reliability to electrical installations across various sectors.
Effective Earth Leakage Protection:
The ABB 5SGY3545L0014 offers protection against earth leakage currents, reducing the risk of electrical shocks and fire hazards.
High Rated Current (45A):
With a rated current of 45A, the circuit breaker is ideal for larger electrical systems and residential or industrial applications.
Sensitivity of 30mA:
The breaker is designed to trip at a residual current of 30mA, making it sensitive enough to protect humans from the dangers of electric shock.
Instantaneous Trip Function:
It ensures immediate disconnection in case of leakage, minimizing the risk of injury or equipment damage.
Compact Design:
The ABB 5SGY3545L0014 is compact and easy to install in electrical panels, helping to save space in distribution boards while providing robust protection.
Complies with International Standards:
This model meets IEC 61008-1 and EN 61008-1 standards, guaranteeing reliable protection and compliance with electrical safety regulations worldwide.
Enhanced Durability:
Constructed with high-quality materials, the ABB 5SGY3545L0014 ensures long-lasting performance, even in harsh environments.
Wide Application Range:
It is suitable for both residential and commercial installations, making it a versatile choice for different sectors.
Low Maintenance:
The RCCB is built to last, with minimal need for maintenance, making it cost-effective in the long term.
Energy Efficiency:
By preventing leakage and unnecessary electrical losses, it contributes to overall system efficiency and reduces the risk of potential damage or failures.
| Parameter | Value |
|---|---|
| Model | ABB 5SGY3545L0014 |
| Part Number | 3BHB006485R0001 |
| Rated Current (In) | 45A |
| Rated Voltage (Ue) | 230V |
| Leakage Current Sensitivity | 30mA |
| Type | Residual Current Circuit Breaker (RCCB) |
| Number of Poles | 2 Poles |
| Dimensions (L x W x H) | 90 mm x 72 mm x 68 mm |
| Weight | 0.45 kg |
| Breaking Capacity (Icn) | 6 kA |
| Trip Time | Instantaneous |
| Temperature Range | -25°C to +55°C |
| Mounting Type | DIN Rail Mountable |
| Compliance | IEC 61008-1, EN 61008-1 |
| Model | Rated Current (In) | Leakage Current Sensitivity | Weight |
|---|---|---|---|
| ABB 5SGY3545L0015 | 25A | 30mA | 0.4 kg |
| ABB 5SGY3545L0016 | 40A | 30mA | 0.43 kg |
| ABB 5SGY3545L0020 | 63A | 30mA | 0.5 kg |
| ABB 5SGY3545L0030 | 80A | 30mA | 0.55 kg |
| ABB 5SGY3545L0040 | 100A | 30mA | 0.6 kg |
| Model | Rated Current (In) | Rated Voltage (Ue) | Weight |
|---|---|---|---|
| ABB S500-SH 1P 10A | 10A | 230V | 0.3 kg |
| ABB S500-SH 3P 16A | 16A | 400V | 0.45 kg |
| ABB 2CDS251001R0001 | 25A | 230V | 0.35 kg |
| ABB 2CDS253001R0611 | 10A | 230V | 0.25 kg |
| ABB 5SGY3545L0002 | 32A | 230V | 0.38 kg |
Q1: What is the function of the ABB 5SGY3545L0014 RCCB?
A1: The ABB 5SGY3545L0014 protects against earth leakage currents, reducing the risk of electrical shocks and fires.
Q2: Can this model be used in residential buildings?
A2: Yes, it is perfect for residential applications, especially in kitchens, bathrooms, and areas where leakage protection is necessary.
Q3: What is the leakage current sensitivity of the ABB 5SGY3545L0014?
A3: This RCCB trips when the leakage current exceeds 30mA, offering protection against electrical shocks.
Q4: How many poles does the ABB 5SGY3545L0014 have?
A4: The device has 2 poles, which is standard for single-phase circuits.
Q5: What is the rated current of this model?
A5: The rated current is 45A, making it suitable for circuits with higher power demands.
Q6: Is the ABB 5SGY3545L0014 suitable for industrial applications?
A6: Yes, it is ideal for use in industrial environments where earth leakage protection is critical.
Q7: Can the ABB 5SGY3545L0014 be used outdoors?
A7: No, it is designed for indoor use and should be installed in a protected environment.
Q8: What is the trip time of this RCCB?
A8: The ABB 5SGY3545L0014 features instantaneous trip functionality for quick disconnection during leakage events.
Q9: What are the dimensions of the ABB 5SGY3545L0014?
A9: The device’s dimensions are 90 mm x 72 mm x 68 mm.
Q10: How is the ABB 5SGY3545L0014 installed?
A10: It is designed to be mounted on a DIN rail, making installation easy and fast in electrical distribution boards.