The 8C‑TPOXA1 is an Input/Output Terminal Assembly (IOTA) module (specifically a Printed Wiring Assembly, PWA) in the Series 8 ecosystem. It acts as the interface between control modules and field wiring: it receives I/O signals and routes them to the control modules, and also provides connectivity, grounding, redundancy synchronization, and diagnostic functions.
Because it is a coated version, it is designed for robustness in industrial environments, with enhanced protection against moisture, dust, corrosion, and other harsh ambient conditions. It supports redundancy (dual IOTA modules synchronized), multiple connector types, and integrates with Series 8 modules and power/grounding systems.
In a control rack, the 8C‑TPOXA1 connects I/O link cables, field wiring, redundant sync cables, and potentially network communications (e.g. via DB9 connectors). It is essential for connecting field devices to logic modules in a clean, modular way.
| Field | Description |
|---|---|
| Brand | Honeywell |
| Series / Platform | Series 8 (S8) I/O and control architecture |
| Module Type | Input/Output Terminal Assembly (IOTA / Interface PWA) |
| Role | Acts as terminal board / interface between field wiring & control modules |
| Coating / Protection | Coated version, for environmental resilience |
| Naming Logic | “8C‑TPOXA1” = Series 8 + Coated + TP (Terminal PWA / I/O interface) + variant A1 |
Thus, 8C‑TPOXA1 is not itself a logic module nor an I/O processing module, but a connectivity/terminal board that supports the signal routing, redundancy, grounding and interface aspects in the Series 8 control architecture.
Here is a table summarizing known / commonly cited parameters for 8C‑TPOXA1, based on available public supplier data and referenced parts. Some values are approximate and should be verified with official manufacturer documentation.
| Parameter | Value / Description |
|---|---|
| Model | 8C‑TPOXA1 |
| Module Type | I/O Terminal Assembly (IOTA PWA) |
| Operating Voltage | 24 V DC (control linkage) |
| Module Current Rating | 430 mA typical for internal circuits (link side) |
| Connectors | FTE A (yellow) & FTE B (green) CAT5e connectors; DB9F connector (for DP networks); CAT5e connector for redundancy sync cable |
| Redundancy Support | Supports dual IOTA modules synchronized via sync cable |
| Operating Temperature | 0 °C to +60 °C |
| Storage Temperature | –40 °C to +85 °C |
| Dimensions | ~ 120 mm × 30 mm × 110 mm (supplier data) |
| Weight | ~ 0.35 kg |
| Environmental Protection | Coated for moisture, dust, corrosion resistance |
| Certifications / Compliance | UL, CE, RoHS (per supplier listing) |
| Module Type / Category | Terminal / interface PWA, not logic processing |
| Power and Ground System | Integrates standard Series 8 I/O link power and grounding scheme |
| Additional Features | Multiple connector interfaces, ease of installation, redundancy sync path |
| Typical Use Network Type | Works with Series 8 I/O link cables and field wiring channels |
The 8C‑TPOXA1 is used in the following industrial settings and control architectures:
Distributed Control Systems / DCS / Process Control: as the terminal board for I/O signals linking to control modules.
Redundant Control Configurations: used in dual IOTA setups to ensure continuity in case one path fails.
Interface to Field Wiring: organizes cable runs, ground loops, signal termination, and connector adaptation between I/O modules and field devices.
Network / Protocol Gateways: in some architectures, it can also serve as the connection point for network communications (e.g. Profibus) in the I/O system.
Harsh Environmental Conditions: in plants with moisture, dust, corrosive gases, where a coated terminal solution is necessary.
Control System Upgrades / Retrofits: when integrating newer I/O modules or upgrading a control rack, 8C‑TPOXA1 provides compatibility with Series 8 wiring.
Safety / Redundancy Demands: in systems requiring failover, continuity, and consistent signal routing under fault conditions.
Because the module is passive interface hardware, its reliability and electrical integrity are critical to overall system stability even though it does not perform processing.
Here are the core advantages of 8C‑TPOXA1:
Environmental Protection via Coating
The coated version withstands moisture, dust, and chemical corrosion, making it suitable for harsh industrial settings.
Support for Redundancy
Designed to support redundant IOTA configurations, enabling fault tolerance and continuity of signal paths.
Multiple Connector Interfaces
It provides CAT5e, DB9, and sync cable connectors, giving flexibility in wiring topologies and network interface.
Integration with Series 8 Power & Grounding
Seamless integration into the Series 8 I/O link, grounding, and power distribution scheme simplifies system deployment.
Compact and Lightweight Design
At approximately 120 × 30 × 110 mm and 0.35 kg, it occupies minimal space and adds little mass to the rack.
Ease of Maintenance and Replacement
Modular, plug‑in design aids in quick replacement and maintenance without extensive rewiring.
Diagnostic / Signal Integrity Assurance
While it does not process logic, it ensures signal continuity and integrity from field devices to logic modules.
Standard Compliance & Reliability
Adherence to UL, CE, and RoHS ensures compatibility with industrial standards and safety regulations.
These strengths make 8C‑TPOXA1 a reliable backbone component in industrial control I/O architectures.
Here are 5 models in the same functional family (IOTA / terminal interface / related to input/output terminal assemblies) or variants:
| Model | Function / Variant | Key Specs / Features |
|---|---|---|
| 8U‑TPOXA1 | Uncoated I/O Terminal Assembly | Similar connectivity, without protective coating |
| 8C‑TCNTA1 | I/O Termination / Terminal Module | Terminal block interface for field wiring |
| 8C‑TCNTA2 | Higher capacity termination module | More connection points, better wiring density |
| 8C‑TCNTA3 | Redundant‑capable termination module | Supports dual wiring paths and failover |
| 8C‑TP0XB1 | Alternate Terminal PWA variant | Slightly different connector or layout variant |
These modules differ in protective coating, number of termination points, redundancy support, or layout. In designs you might mix them depending on field wiring complexity, location, and redundancy scheme.
Here are 5 widely used Honeywell modules of other kinds (logic, I/O, controller) frequently co‑deployed in the same control systems:
| Model | Module Type / Role | Key Specs / Use |
|---|---|---|
| 8C‑TDODA1 | Digital Output Module | Drives discrete loads, 32 output channels |
| 8C‑TDOLA1 | Digital Input Module | Receives discrete field signals |
| 8C‑TAIDB1 | Analog Input Module | Reads analog 4–20 mA signals |
| 8C‑TAOXA1 | Analog Output Module | Sends analog control signals |
| 8C‑PCNT03 | Control / CPU Module | Executes control logic, coordinates I/O |
Q1: What does 8C‑TPOXA1 do in a control system?
A1: It functions as a terminal interface (I/O assembly) that routes signals between the field and the control modules, providing connectors, synchronization, and grounding in the process.
Q2: Why choose a coated version (8C) instead of uncoated?
A2: The coating gives it protection against moisture, dust, and corrosive environments, improving long-term reliability in harsh industrial plants.
Q3: What is the module’s connector set?
A3: It has FTE A & B (CAT5e) connectors, a DB9F connector (for DP networks), and a CAT5e redundancy sync cable connector.
Q4: Can it be used in redundant I/O paths?
A4: Yes — it supports dual IOTA configurations synchronized via a sync cable for redundancy.
Q5: What are its dimensions and weight?
A5: Roughly 120 mm × 30 mm × 110 mm, weighing about 0.35 kg in common listings.
Q6: What is the operating temperature range?
A6: 0 °C to 60 °C nominal; storage range –40 °C to +85 °C.
Q7: What current does the module draw internally?
A7: Approx. 430 mA for its internal circuits (link side) as commonly listed in spec sheets.
Q8: Does it provide any logic or signal processing?
A8: No — it is a passive terminal interface; it does not convert, filter, or process I/O signals.
Q9: How is it installed or replaced?
A9: It mounts into the I/O rack or mounting scheme and connects to I/O link cables and field wiring. It is modular, so replacement is relatively straightforward.
Q10: What should I check when integrating 8C‑TPOXA1?
A10: Verify connector compatibility, redundancy scheme, I/O link voltage / cable length, environmental protection needs, physical space in rack, and grounding / power distribution.
Authenticity guarantee
All product specifications are original and authentic imported products. We have an annual sales volume of 300 million yuan, and we only produce original and authentic products. All customers who cooperate with us directly online can enjoy low discounts.
Free warehouse
We have a complete range of product models, 80% of conventional models are in stock, and we have established channels in Asia, Africa, North America, South America, and Europe, effectively shortening the order processing time and satisfying customers in a timely manner.
Technical Team
Fast delivery. Spot goods can be shipped on the same day, and the delivery time transaction is 20% faster than that of peers on average, with a delivery time accuracy rate of 99%.
Thoughtful after-sales service
24-hour after-sales service guarantee team, professional and standardized management service system.