| Parameter | Specification | Notes |
|---|---|---|
| Model | FC-TSHART-1620M | Safe analog input module with HART interface |
| Number of Channels | 16 analog input channels | Divided in two groups of 8 channels each |
| Signal Input Type | 0-20 mA or 4-20 mA current loop | Standard industrial analog current input |
| Input Current Range | 0 to 25 mA | Supports transmitter loop current range |
| Input Resistance | 250 Ω ±1% | Shunt resistor for current measurement |
| Output Voltage to Safe Input Module | 0 to 4 V DC | Voltage output compatible with safe I/O modules |
| Supply Voltage | Typically 30 V DC | External power supply for the module and loops |
| Fuse Rating | 315 mA, slow blow | For power and loop protection |
| Operating Temperature | -40 °C to +85 °C | Suitable for harsh industrial environments |
| Dimensions (L × W × H) | 210 mm × 70 mm × 60 mm | Physical size of the module |
| Weight | Approximately 0.30 kg | Module mass |
| Terminal Type | Screw terminals | Max cable size 2.5 mm², recommended torque 0.5 Nm |
| Explosion Protection | Suitable for Class I Div 2 hazardous locations | Certification for hazardous area use |
| HART Communication | Supported | Allows HART signal communication and diagnostics |
The FC-TSHART-1620M is a high-quality field termination assembly (FTA) module designed specifically for safe analog input applications with HART protocol support. This module converts analog 0(4)-20 mA signals from field transmitters into precise voltage signals compatible with safety logic controllers. The embedded HART capability enables simultaneous digital communication on the same loop, allowing remote diagnostics and device configuration.
It integrates power supply distribution, signal conditioning, and diagnostic monitoring in a compact, rugged housing suitable for hazardous industrial environments. The module supports up to 16 analog input channels grouped into two sets, simplifying wiring and enhancing safety in process control and safety instrumented systems.
Safety Instrumented Systems (SIS): Provides safe analog signal inputs from field transmitters for safety logic evaluation.
Process Control Plants: Used in chemical, petrochemical, oil and gas, and power plants for critical measurement signals.
Hazardous Locations: Designed for installation in Class I Division 2 zones, meeting rigorous safety standards.
HART-Enabled Devices: Facilitates integration and communication with HART-capable transmitters without extra hardware.
Remote Field Cabinets: Suitable for installation near field devices to minimize signal degradation.
Retrofitting and Upgrades: Ideal for upgrading existing analog input systems to add safety and HART capabilities.
Integrated HART Multiplexing: Simplifies digital communication on analog loops, providing access to diagnostics and configuration.
High Accuracy: ±0.10% measurement precision ensures reliable and repeatable data.
Power Distribution: Built-in transmitter loop powering with safe current limiting.
Rugged Construction: Designed for extreme temperature ranges and harsh industrial conditions.
Hazardous Area Approval: Suitable for installation in Class I Div 2 environments.
Compact Form Factor: DIN-rail mountable design optimizes cabinet space.
Comprehensive Diagnostics: Detects wiring faults, loop current anomalies, and power issues.
Ease of Installation: Screw terminals with secure wire connections simplify field wiring.
Brand: Honeywell
Series: Safety / Field Termination Assemblies (FTA) / Safe Analog Input Modules
Series Characteristics: Modules designed to safely interface analog/digital field signals to safety logic with support for hazardous area installations and digital communication (HART).
| Model | Function | Key Specifications |
|---|---|---|
| FC-TSHART-1620M | Safe Analog Input with HART | 16 channels, 0-20 mA, 0-4 V output, HART enabled |
| FC-TSAI-1620M | Safe Analog Input (No HART) | 16 channels, 0-20 mA input, standard FTA |
| FC-TSFIRE-1624 | Fire & Gas Safety Digital Input | 24 digital inputs for fire/gas detectors |
| FC-TSDI-1624 | Safe Digital Input Module | 24-channel digital input |
| FC-TSAO-0220M | Safe Analog Output Module | Analog output for actuator control |
| Model | Function | Key Specs |
|---|---|---|
| FC-TSAO-0220M | Safe Analog Output Module | 2 channels, 0-20 mA output |
| FC-SAI-1620M | Safe Analog Input Module | 16 channels, 0-20 mA input, no HART |
| FC-TSDI-1624 | Safe Digital Input Module | 24 discrete inputs |
| FC-TSDI-16UNI | Universal Digital Input Module | Supports voltage and contact inputs |
| FC-TSDOL-0424C | Safe Digital Output Module | 24-channel digital output |
Q1: What types of signals does the FC-TSHART-1620M accept?
A1: It accepts 0-20 mA or 4-20 mA analog current signals from field transmitters.
Q2: How many channels are available on this module?
A2: There are 16 analog input channels available.
Q3: Does this module support HART communication?
A3: Yes, it supports HART multiplexing for communication and diagnostics.
Q4: What is the operating temperature range?
A4: The module operates between -40°C and +85°C.
Q5: What are the physical dimensions and weight?
A5: The size is approximately 210 mm x 70 mm x 60 mm, weighing around 0.30 kg.
Q6: How is power supplied to the transmitters?
A6: The module distributes power to transmitter loops with built-in current limiting and protection.
Q7: What safety certifications does the module have?
A7: It is suitable for Class I Division 2 hazardous locations.
Q8: Can it detect wiring faults or loop issues?
A8: Yes, it provides diagnostic feedback on wiring and loop current status.
Q9: What kind of mounting does the module use?
A9: The module is designed for DIN rail mounting or flange mounting.
Q10: In which industries is this module typically used?
A10: It is commonly used in oil & gas, chemical, petrochemical, power plants, and other process industries.
Authenticity guarantee
All product specifications are original and authentic imported products. We have an annual sales volume of 300 million yuan, and we only produce original and authentic products. All customers who cooperate with us directly online can enjoy low discounts.
Free warehouse
We have a complete range of product models, 80% of conventional models are in stock, and we have established channels in Asia, Africa, North America, South America, and Europe, effectively shortening the order processing time and satisfying customers in a timely manner.
Technical Team
Fast delivery. Spot goods can be shipped on the same day, and the delivery time transaction is 20% faster than that of peers on average, with a delivery time accuracy rate of 99%.
Thoughtful after-sales service
24-hour after-sales service guarantee team, professional and standardized management service system.