Brand: Honeywell
Series: Safety / Field Termination Assembly (FTA) / Safe Analog Input Modules
Positioning: The FC‑TSHART‑1620M is a safe analog input field termination assembly module with HART interface support. It is designed to serve as an interface between field analog sensors / transmitters (0/4–20 mA) and the safety logic / analog input modules (e.g. a safe high‑density analog input module). This FTA module not only provides signal conversion and conditioning, but also supports HART multiplexing capability, power distribution, and diagnostic monitoring suited for hazardous locations (e.g. Class I Division 2) setups.
It typically sits in the link between field sensors and safety controllers, allowing the system to read analog measurements (pressure, temperature, flow, level) in a safe, monitored, and HART‑capable way.
下面是整理的 FC‑TSHART‑1620M 主要技术参数(含尺寸与重量)。这些数据仅用于参考设计,需要以官方手册为准。
| Parameter | Value | Remarks / Notes |
|---|---|---|
| Model | FC‑TSHART‑1620M | Safe analog input FTA with HART interface |
| Number of Analog Input Channels | 16 channels | Divided into 2 groups of 8, common 0 V lines |
| Signal Type | 0–20 mA or 4–20 mA | Standard analog current loop input |
| Input Current Range | 0 to 25 mA | Acceptable transmitter current range |
| Input Resistance | 250 Ω ±1% | Shunt resistor for the input loop |
| Output to External Transmitters (Vext) | Resistive coupling, output resistance ~ 270 Ω ±5% | For energizing loops |
| Igniting Current (Per Channel) | < 120 mA at 30 V DC | Ability to drive transmitter loop current |
| Output to Safe Analog Input Module | 0–4 V DC | Interface to the safe module domain |
| Accuracy | ±0.10% (nominal) | Precision in signal conversion |
| Power Supply | External 30 V DC typical | For module electronics and loop supply |
| Fuse Rating | 315 mA slow fuse (5 × 20 mm) | For power / loop protection |
| Maximum Output Current per Fuse | 220 mA | Limitation per fused group |
| Operating Temperature | –40 °C to +85 °C (some sources) | Wide industrial range |
| Protection / Location Class | Supports Class I Division 2 setups | For hazardous area applications |
| Mounting / Form Factor | Snap‑in DIN rail or mounting flange | Standard industrial mounting |
| Dimensions (L × W × H) | 210 mm × 70 mm × 60 mm | Module body size (reference) |
| Weight | ~0.30 kg | Approximate mass of module |
| Terminal Wiring | Screw terminals | Max wire: 2.5 mm², strip length 7 mm, torque ~ 0.5 Nm |
| HART Interface Capability | Supports HART multiplex units | Enables HART signalling / diagnostics |
The FC‑TSHART‑1620M operates as a safe analog input FTA with added HART compatibility. Its duties include:
Analog signal conversion: Converts 0(4)–20 mA field sensor signals into voltage signals (0–4 V) for the safe analog input module domain, preserving accuracy.
HART multiplex interface: It is capable of interfacing with HART multiplexers (e.g. those from MTL, Pepperl+Fuchs) to allow communication with field transmitters over the same loop.
Power distribution: It distributes power to each transmitter loop with current and voltage limitation, ensuring safe operation in hazardous areas.
Diagnostic monitoring: It monitors external supply, transmitter current draw, fault detection, and likely wiring failures.
Field termination convenience: Screw terminal design, DIN rail snap mounting, organized layout for wiring and field loops.
Hazardous area suitability: Designed to operate in environments with Class I Division 2, ensuring safe performance even in zones with explosive atmosphere risk.
In application, sensors (pressure, temperature, flow, level) send analog current signals; the TSHART FTA conditions these signals, injects loop power, reads diagnostics, and conveys a safe, clean voltage to the safety logic modules — all while enabling HART communication in parallel.
Typical use cases:
Safety system analog input paths
In Safety Instrumented Systems (SIS), this module provides input for analog sensors (e.g. pressure, temperature, level) used in safety logic evaluation.
Field transmitter integration with HART
In plants where HART-enabled transmitters are used, this module allows combining measurement signal and digital diagnostics on the same loop.
Hazardous area installations
Modules installed near or in hazardous zones, where explosion-proof or safe area interfaces are required.
Process control with safety overlay
In process plants (oil & gas, chemicals, petrochemicals, power), this module helps integrate process analog signals into safety controllers.
Distributed instrumentation cabinets
In remote field cabinets, close to sensors, reducing signal degradation and facilitating local termination.
Upgrades / retrofits
Retrofitting older analog I/O installations with safety / HART capability, enabling diagnostics and safe integration.
Key advantages of FC‑TSHART‑1620M:
HART support integrated
Unlike basic analog input FTAs, this module supports HART communication, enabling remote transmitter diagnostics.
High precision & accuracy
Low error (±0.10%) conversion maintains integrity of measurement data.
Powering capability
Can energize transmitter loops while maintaining safe current limits and diagnostics.
Robust in hazardous environments
Designed for Class I Division 2, with isolation, protection, and rugged construction.
Compact & DIN-mountable
Efficient footprint simplifies panel layout and wiring.
Diagnostic feedback
Capability to monitor supply, loop health, detect wiring faults, enabling maintenance alerts.
Reliable and stable
Built for industrial reliability with wide temperature tolerance and proven architecture.
Integration-ready
Works seamlessly with safe analog input modules and safety controllers.
以下是 5 个与 FC‑TSHART‑1620M 在功能、系列或用途上相关或互补的型号:
| Model | Function / Role | Key Differences / Highlights |
|---|---|---|
| FC‑TSHART‑1620M | (Base) Safe Analog Input with HART | 16-ch, HART-enabled FTA |
| FC‑TSAI‑1620M | Safe Analog Input (no HART) | Similar analog input module without HART multiplexing |
| FC‑TSFIRE‑1624 | Fire/gas safety input module | Discrete input for fire/gas detectors |
| FC‑TSDI‑1624 | Safe digital input module | Discrete signals instead of analog |
| FC‑TSAO‑0220M | Safe analog output module | For output to analog actuators / valves |
这些模块通常协同构建安全 I/O 架构:模拟输入、数字输入、模拟输出等模块共同使用。
以下是 5 个该品牌(Honeywell)内较为常用或较热门的模块型号:
| Model | Purpose / Type | Typical Use |
|---|---|---|
| FC‑TSAO‑0220M | Safety analog output | Drive 4–20 mA actuators in safety loops |
| FC‑SAI‑1620M | Safe analog input | Read analog sensors into safety logic |
| FC‑TSDI‑1624 | Safe digital input | Read discrete signals (switches, alarms) |
| FC‑TSDI‑16UNI | Universal digital input | Accepts various discrete types (voltage, contact) |
| FC‑TSDOL‑0424C | Safe digital output | Drives discrete output elements (alarms, relays) |
Q1: What signal types does FC‑TSHART‑1620M accept?
A1: It accepts standard analog current loop signals — 0–20 mA or 4–20 mA from field transmitters.
Q2: How many analog channels does it support?
A2: It supports 16 channels, organized into two groups of 8 with common reference.
Q3: What is the module’s accuracy?
A3: It provides about ±0.10% accuracy in converting the analog signal.
Q4: Does it support HART communication?
A4: Yes — it includes HART interface / multiplexing capability, enabling diagnostics and configuration over the analog loop.
Q5: What are its physical dimensions and weight?
A5: Dimensions: approx 210 × 70 × 60 mm. Weight: about 0.30 kg.
Q6: What temperature range can it operate in?
A6: It is designed for –40 °C to +85 °C operational range in harsh industrial sites.
Q7: How is power provided to transmitters?
A7: The module distributes loop power to each transmitter, with current/voltage limitation, ensuring safe operation in hazardous zones.
Q8: What protection or certification does it offer?
A8: It is designed for Class I Division 2 hazardous locations, with isolation and diagnostics suited for safe system integration.
Q9: Can this module detect wiring faults or transmitter issues?
A9: Yes — it monitors loop current, supply status, and can detect open circuits, shorts, or abnormal behavior on channels.
Q10: In which systems or industries is this module typically used?
A10: It’s widely used in oil & gas, petrochemical, chemical, power generation, refining, and process plants where analog measurement and safety overlay are critical.
Authenticity guarantee
All product specifications are original and authentic imported products. We have an annual sales volume of 300 million yuan, and we only produce original and authentic products. All customers who cooperate with us directly online can enjoy low discounts.
Free warehouse
We have a complete range of product models, 80% of conventional models are in stock, and we have established channels in Asia, Africa, North America, South America, and Europe, effectively shortening the order processing time and satisfying customers in a timely manner.
Technical Team
Fast delivery. Spot goods can be shipped on the same day, and the delivery time transaction is 20% faster than that of peers on average, with a delivery time accuracy rate of 99%.
Thoughtful after-sales service
24-hour after-sales service guarantee team, professional and standardized management service system.