• Yokogawa SCP451-51 S1 Processor Module
  • Yokogawa SCP451-51 S1 Processor Module
  • Yokogawa SCP451-51 S1 Processor Module
  • Yokogawa SCP451-51 S1 Processor Module
📘 Product Overview – SCP451-51 S1 The SCP451-51 S1 is a high-reliability Processor Module used in safety instrumented systems (SIS). Designed for mission-critical operations, it is an essential componen……
Yokogawa SCP451-51 S1 Processor Module
  • Yokogawa
  • SCP451-51 S1
  • Processor Module
  • Japan
  • 123 mm × 122 mm × 100 mm
  • 1.2kg
  • Xiamen, China
  • New & In Stock
  • T/T, PayPal, Western Union
  • 1 Year
  • 1-3 Working Days
  • DHL, UPS, TNT, FedEx and EMS.
  • 24-Hour Service
  • COO
  • 183

Our advantage

Yokogawa SCP451-51 S1 Processor Module

Global Logistics

We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.

Yokogawa SCP451-51 S1 Processor Module

Brand new and original

Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.

Yokogawa SCP451-51 S1 Processor Module

24-hour service

We provide 7*24 hours service to our customers. We will be there whenever you need us.

Yokogawa SCP451-51 S1 Processor Module

Price advantage

All our products are priced very favorably because we have our own warehouse and supply.


Company Information
E-mail [email protected]
Mobile +8615980777398
Whatsapp +8615980777398
WeChat 15980777398

📘 Product Overview – SCP451-51 S1

The SCP451-51 S1 is a high-reliability Processor Module used in safety instrumented systems (SIS). Designed for mission-critical operations, it is an essential component in industrial safety solutions. As part of a safety control system, this module ensures deterministic logic execution, reliable communication, and failsafe operations under any condition.

The S1 variant represents a specific configuration or revision with optimized components or firmware for enhanced safety integrity or system compatibility, typically certified for SIL-3 safety applications.


📊 Technical Specifications – SCP451-51 S1

Parameter Specification
Model SCP451-51 S1
Function Safety Logic Processor Module
Safety Certification SIL-3 (Safety Integrity Level 3) compliant
Architecture Dual-redundant (hot standby capable)
Processor Type 32-bit high-speed logic processor
Memory 128 MB RAM, 64 MB Flash
Communication Protocols Vnet/IP, RS-232, RS-485, Ethernet
Diagnostic Functions Self-checks, watchdog timer, memory parity check
Voltage Supply 24 V DC (via system backplane)
Logic Scan Time < 100 ms typical
Operating Temperature –10°C to +55°C
Storage Temperature –40°C to +85°C
Relative Humidity 5%–95% RH (non-condensing)
Mounting Method Rack mount (ProSafe-RS system)
Protection Rating IP20 (when installed in cabinet)
Shock Resistance 10 G, 11 ms (IEC standard)
Vibration Resistance 2.5 G, 10–500 Hz
Dimensions (H × W × D) 123 mm × 122 mm × 100 mm
Weight 1.2 kg
Expansion Connects to I/O modules via backplane
Cooling Passive convection

🏭 Applications

  • Emergency Shutdown Systems (ESD)
    Quickly shuts down operations when unsafe conditions are detected, preventing escalation.

  • Fire & Gas Detection Systems (F&G)
    Processes real-time inputs from sensors to activate alarms and suppression systems.

  • High-Integrity Pressure Protection Systems (HIPPS)
    Ensures over-pressurization does not damage equipment or endanger personnel.

  • Burner Management Systems (BMS)
    Controls complex burner sequences, ensuring safe ignition and flame monitoring.

  • Pipeline Monitoring Systems
    Ensures safety logic is in place for valve operations and pressure regulation.

  • Critical Alarm Management
    Ensures operator awareness during critical events through reliable alert generation.


✅ Product Advantages

  • SIL-3 Certification
    Ensures compliance with the highest industrial safety standards.

  • Dual-Redundancy
    Eliminates single points of failure via hot-standby configuration.

  • High-Speed Logic Processing
    Ensures real-time response in time-critical safety scenarios.

  • Modular Scalability
    Seamlessly integrates with additional I/O and communication modules.

  • Advanced Diagnostics
    Offers system health checks, self-testing, and predictive alerts.

  • Wide Environmental Compatibility
    Operates reliably across a wide range of temperature and humidity conditions.


🏷️ Brand & Series

Field Description
Brand Yokogawa
Series ProSafe-RS
Product Category Safety Processor Module
Certification SIL-3, IEC 61508 compliant
Use Environment Industrial Automation, Safety

🔁 Related Models (Same Series / Functionally Similar)

Model Description Dimensions (mm) Weight (kg) Key Notes
SCP451-11-S1 Earlier model of safety processor module 123 × 122 × 100 1.2 Compatible with SSC50S control unit
SCP451-53 Analog output module 123 × 122 × 100 1.5 Provides 4–8 analog outputs
SCP451-DI Digital input module 123 × 122 × 100 1.3 16-channel digital inputs
SCP451-DO Digital output module 123 × 122 × 100 1.4 16 isolated outputs
SCP451-AI Analog input module 123 × 122 × 100 1.6 High-accuracy analog signal input

🔝 Other Popular Yokogawa Models

Model Description Dimensions (mm) Weight (kg) Function Type
CP701 Field Control CPU Module 200 × 100 × 50 1.7 DCS central controller
ADV151-P00 Digital Output Module 123 × 122 × 100 0.9 Discrete signal output
ANB10D-420 Remote I/O Network Node 150 × 100 × 80 1.2 Field communication node
VI702 Vnet/IP Communication Interface 110 × 90 × 40 0.6 Network bridge for I/O
EC401-51 Expansion Coupler Module 123 × 122 × 100 1.1 I/O expansion interface


❓ FAQ – SCP451-51 S1

Q1: What does the SCP451-51 S1 module do?
A1: It executes safety-critical logic and controls communications between field devices and central control units within a safety system.

Q2: Is this module compliant with safety standards?
A2: Yes, it is certified for SIL-3 applications in accordance with IEC 61508 standards.

Q3: What kind of redundancy does it support?
A3: The module supports dual-redundant configurations with hot standby switching.

Q4: Can the SCP451-51 S1 be used in hazardous areas?
A4: The module itself is not explosion-proof but is typically housed in certified enclosures when used in hazardous zones.

Q5: How is the module powered?
A5: It receives 24 V DC power via the system backplane within the rack.

Q6: How is logic uploaded or modified?
A6: Using certified engineering tools via the system interface, under secure and controlled environments.

Q7: Can I use this module in a non-Yokogawa system?
A7: It is designed specifically for ProSafe-RS platforms and may not be compatible with third-party systems.

Q8: What happens during a module failure?
A8: In redundant systems, the backup processor automatically takes over, ensuring no interruption in safety control.

Q9: Is regular maintenance required?
A9: While minimal, scheduled diagnostics and firmware checks are recommended as part of lifecycle safety management.

Q10: How does this differ from SCP451-11?
A10: The S1 suffix typically indicates enhanced or updated hardware/firmware and possibly increased compatibility or performance.