• Epro PR9670/110-100 Eddy Current Sensor
  • Epro PR9670/110-100 Eddy Current Sensor
  • Epro PR9670/110-100 Eddy Current Sensor
  • Epro PR9670/110-100 Eddy Current Sensor
Product Overview The Epro PR9670/110-100 Eddy Current Sensor is an industrial non-contact sensing component designed for machinery monitoring applications. It belongs to the Epro PR9670 product family a……
Epro PR9670/110-100 Eddy Current Sensor
  • Epro
  • PR9670/110-100
  • Eddy Current Sensor
  • Germany
  • Optional
  • 3 kg
  • Xiamen, China
  • New & In Stock
  • T/T, PayPal, Western Union
  • 1 Year
  • 1-3 Working Days
  • DHL, UPS, TNT, FedEx and EMS.
  • 24-Hour Service
  • COO
  • 8

Our advantage

Epro PR9670/110-100 Eddy Current Sensor

Global Logistics

We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.

Epro PR9670/110-100 Eddy Current Sensor

Brand new and original

Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.

Epro PR9670/110-100 Eddy Current Sensor

24-hour service

We provide 7*24 hours service to our customers. We will be there whenever you need us.

Epro PR9670/110-100 Eddy Current Sensor

Price advantage

All our products are priced very favorably because we have our own warehouse and supply.


Company Information
E-mail [email protected]
Mobile +8615980777398
Whatsapp +8615980777398
WeChat 15980777398

Product Overview

The Epro PR9670/110-100 Eddy Current Sensor is an industrial non-contact sensing component designed for machinery monitoring applications. It belongs to the Epro PR9670 product family and is intended for detecting changes in the position or displacement of conductive metallic targets.

Eddy-current sensing technology is widely used in rotating machinery because it can measure the movement of a metal shaft without requiring direct mechanical contact. This makes it useful in applications where continuous monitoring of shaft position, displacement, and vibration is important for equipment condition assessment.

The PR9670/110-100 can be considered for use in industrial machinery monitoring installations involving turbines, compressors, pumps, motors, and other rotating equipment. In a typical measurement arrangement, the sensor works with a compatible signal-conditioning device that processes the sensing signal and provides information to a monitoring or protection system.

One important ordering consideration is the sensor-head diameter. The supplied product information identifies this dimension as optional, meaning the required probe configuration should be confirmed before purchase. The stated 3 kg weight is the shipping weight and should not be interpreted as the net weight of the sensor alone.

For maintenance and replacement projects, identifying the complete model number and confirming the associated cable, probe-head configuration, mounting arrangement, and signal-conditioning requirements are essential steps.

Technical Specifications

Parameter Specification
Brand Epro
Product Model PR9670/110-100
Product Series PR9670
Product Type Eddy Current Sensor
Measurement Principle Eddy-current induction
Measurement Method Non-contact sensing
Target Type Electrically conductive metallic materials
Typical Measurement Purpose Displacement and position monitoring
Machinery Monitoring Use Shaft movement and vibration-related monitoring
Sensor Head Diameter Optional configuration
Signal Processing Requires a compatible signal-conditioning arrangement
Typical Installation Industrial machinery monitoring systems
Shipping Weight 3 kg
Net Product Weight Not specified
Dimensions Not specified; confirm the supplied configuration
Manufacturer / Brand Identification Epro

Note: Numerical measuring range, sensitivity, linearity, frequency response, cable length, supply requirements, and temperature limits are not specified here because they must be confirmed against the exact probe configuration and its compatible signal conditioner.

Function and Working Principle

The PR9670/110-100 uses the eddy-current measurement principle. This technology allows a sensor to detect the position of a conductive target without touching it.

1. Generation of an Electromagnetic Field

An eddy-current probe contains a sensing coil. When an appropriate high-frequency electrical signal is applied through a compatible measurement circuit, the coil produces an alternating electromagnetic field around the probe tip.

This field extends toward the nearby metallic target. The characteristics of the field depend on the probe construction, operating electronics, target material, and distance between the sensor and target.

2. Interaction with the Metallic Target

When a conductive metal surface enters the electromagnetic field, electrical currents known as eddy currents are induced within the target.

These currents generate an opposing electromagnetic field that influences the electrical characteristics of the probe coil. Changes in the distance between the probe and target therefore produce measurable changes in the sensor’s electrical response.

This allows the system to detect changes in the position of the metallic object without requiring physical contact.

3. Signal Conditioning

The raw sensor response generally needs to be processed by a compatible signal conditioner. The conditioner provides the electrical interface and signal processing required to convert the probe response into a usable measurement signal.

The exact conditioner must be selected according to the sensor’s electrical characteristics and the requirements of the monitoring system. A probe should not be connected to an arbitrary converter simply because both devices use eddy-current technology.

4. Displacement Measurement

In a rotating machine, the sensor can be installed facing a conductive shaft surface. As the shaft moves relative to the probe, the gap changes and the measurement system detects the corresponding signal variation.

Depending on the installation and monitoring configuration, this information can help identify changes in shaft position, radial movement, or axial displacement.

5. Vibration Monitoring

When a shaft moves repeatedly during rotation, the distance between the shaft surface and the stationary probe changes over time.

The resulting measurement signal can be processed by the monitoring system to evaluate shaft vibration characteristics. Engineers can use this information alongside other operating measurements to assess machine condition.

The actual measurement range and accuracy depend on the complete sensor and signal-conditioning configuration.

Role in Industrial Machinery Monitoring Systems

The PR9670/110-100 can serve as a sensing element in a machinery monitoring arrangement. Its role is to detect physical movement at the measurement location and provide information for further signal processing.

Shaft Position Monitoring

Shaft position is an important operating parameter in many rotating machines. Changes in shaft position can be associated with mechanical movement, bearing conditions, thermal expansion, or changes in operating loads.

A correctly installed non-contact probe can provide continuous position-related information for the monitoring system.

Radial Displacement Monitoring

Radial displacement monitoring is used to observe shaft movement perpendicular to the shaft centerline.

In suitable applications, probes are installed at carefully selected positions around the shaft. The monitoring system processes the resulting signals to evaluate shaft movement and identify abnormal changes.

Axial Displacement Monitoring

Axial position measurements help engineers observe movement along the shaft axis. This information can be important for machines where thrust conditions and axial clearance require monitoring.

The probe orientation, mounting arrangement, and measurement-system configuration must be designed for the intended measurement direction.

Integration with Protection Systems

A machinery protection system can receive processed sensor signals and compare measurements against configured alarm or trip limits.

If a monitored parameter moves outside the permitted operating range, the system can alert operators or initiate an appropriate protective response.

The sensor itself does not independently perform all alarm, trip, or diagnostic functions. Those functions depend on the connected monitoring equipment and the overall protection-system design.

Industrial Applications

The Epro PR9670/110-100 can be considered for industrial applications where non-contact measurement of conductive metallic targets is required.

1. Steam Turbines

Steam turbines contain high-speed rotating components that require continuous condition monitoring. Shaft displacement and vibration measurements can help maintenance teams evaluate mechanical behavior during operation.

A suitable eddy-current measurement arrangement can provide information about shaft movement and support machinery protection strategies.

2. Gas Turbines

Gas turbines operate under demanding mechanical and thermal conditions. Monitoring rotor movement and vibration is important for identifying abnormal operating behavior.

Non-contact probes can be used at appropriate measurement locations when their operating limits and installation requirements match the turbine design.

3. Industrial Compressors

Centrifugal compressors rely on accurately controlled rotating assemblies. Changes in shaft movement can be relevant to bearing performance, rotor stability, and mechanical condition.

A properly configured monitoring system can use displacement-related measurements to help identify developing mechanical problems.

4. Pumps and Pumping Equipment

Large industrial pumps may operate continuously in water treatment, chemical processing, oil and gas, and power-generation facilities.

Monitoring shaft movement can provide useful information about the condition of rotating assemblies. Sensor placement must account for the pump’s construction, shaft geometry, and operating environment.

5. Electric Motors and Generators

Large motors and generators may require continuous monitoring of rotor movement and vibration.

Non-contact measurement can help assess shaft behavior without adding mechanical contact at the measurement point. The selected sensor and signal conditioner must be suitable for the specific machine.

6. Industrial Gearboxes

Gearboxes contain rotating shafts and mechanical transmission components that may experience changes in alignment, clearance, or loading.

Where the measurement target and installation geometry are suitable, displacement monitoring can contribute to a broader condition-monitoring strategy.

Installation and System Integration

Correct installation is essential for obtaining stable and meaningful measurements from an eddy-current sensor.

1. Confirm the Complete Sensor Configuration

Before installation, verify that the supplied unit is the PR9670/110-100 and that its configuration matches the existing monitoring system.

Check the sensor-head diameter, mounting thread, cable arrangement, connector type, and any required extension cable. The sensor-head diameter is listed as optional, so it should not be assumed to have one fixed value.

2. Check the Target Material

Eddy-current sensors operate by interacting with conductive targets. The target material therefore affects the measurement response.

Confirm that the monitored shaft or metallic surface is compatible with the sensor system. Material changes, surface conditions, and target geometry can influence calibration and measurement performance.

3. Prepare the Mounting Location

The sensor should be mounted securely to prevent unwanted movement during machine operation.

The mounting arrangement must maintain the required mechanical stability and measurement orientation. Loose brackets, vibration at the mounting point, or incorrect alignment can introduce measurement errors.

4. Establish the Correct Probe Gap

The distance between the probe tip and the target is an important installation parameter.

Set the gap according to the manufacturer’s instructions and the specifications of the complete probe and conditioner combination. Do not use a measurement range from another PR9670 model as a substitute for the exact model’s data.

5. Connect the Compatible Signal Conditioner

Confirm the correct signal conditioner and electrical interface before connecting the probe.

Check the probe wiring, cable type, connector arrangement, grounding, and shielding requirements. Incorrect connections or incompatible signal-conditioning equipment may result in unstable signals or incorrect measurements.

6. Route and Protect the Cable

Route the sensor cable away from high-power conductors, switching devices, and other potential sources of electromagnetic interference where required.

Avoid sharp bends, excessive mechanical tension, and contact with hot or moving machine parts. Secure the cable so that vibration does not damage the connection.

7. Calibrate and Verify the Measurement

After installation, follow the manufacturer’s calibration and commissioning procedure.

Verify the sensor gap, signal response, measurement polarity, and monitoring-system scaling. Compare the processed signal with the expected mechanical condition before enabling alarms or protection functions.

Compatible System Components

An eddy-current sensor is normally part of a complete measurement chain. The following components may be relevant to an installation, but exact compatibility must be confirmed for the PR9670/110-100 configuration.

Component Function Integration Considerations
Compatible signal conditioner Processes the probe’s electrical response Must match the exact probe characteristics
Extension cable Connects the sensor to the conditioner Verify cable type, length, impedance, and connector arrangement
Monitoring module Receives and processes measurement signals Confirm supported input type and signal scaling
Machinery protection rack Monitors machine condition and alarm limits Verify the sensor and conditioner combination
PLC or DCS Receives process or condition-monitoring information Integration depends on the monitoring system’s output interface
Sensor mounting bracket Holds the probe in the correct position Must provide mechanical stability and suitable adjustment
Metallic measurement target Provides the conductive surface being monitored Confirm material, geometry, and surface condition
Shielded cable accessories Help reduce electrical interference Follow the system’s grounding and shielding requirements

Do not assume that every component listed above is supplied with the sensor. Confirm the actual order contents and system requirements before purchasing.

Alternative Models and Replacement Considerations

The PR9670/110-100 belongs to the Epro PR9670 family. Other models in the same family may have different probe dimensions, measurement characteristics, cable configurations, or intended applications.

Alternative Model or Component Replacement Consideration
Epro PR9670/111-100 A related PR9670-series model; verify probe dimensions and electrical characteristics
Epro PR9670/113-100 A related model with its own configuration; do not assume identical measurement specifications
Epro PR9670/115-100 A different probe configuration that requires detailed compatibility checks
Epro PR6423 Series Another Epro eddy-current sensor family; verify the complete measurement chain
Epro PR6424 Series A related displacement-sensing family with model-specific probe and conditioner requirements
Compatible Epro signal conditioner May be required when replacing a sensor; verify exact electrical matching

Before choosing a replacement, compare:

  • Complete sensor model number.
  • Probe-head diameter and mechanical dimensions.
  • Mounting thread and installation arrangement.
  • Cable length, cable type, and connector.
  • Measurement range and sensitivity.
  • Signal-conditioning requirements.
  • Target material and shaft geometry.
  • Operating temperature and environmental limits.
  • Monitoring-system input characteristics.
  • Calibration and alarm configuration.

A sensor from the same manufacturer is not automatically interchangeable. Even models within the same product family can have different electrical and mechanical characteristics.

Key Advantages

Non-Contact Measurement

Eddy-current technology detects the position of conductive targets without requiring direct physical contact. This avoids mechanical contact between the probe and the monitored shaft during normal measurement.

Support for Continuous Monitoring

A properly installed sensor can provide measurement information to a continuous machinery monitoring system, supporting ongoing equipment-condition assessment.

Application in Rotating Machinery

Non-contact displacement sensing is relevant to turbines, compressors, pumps, motors, generators, and other equipment containing rotating shafts.

Integration with Signal-Conditioning Equipment

The sensor can form part of a larger measurement arrangement that processes probe signals and provides useful information to machinery monitoring equipment.

Support for Maintenance Planning

Displacement and vibration-related measurements can help maintenance teams identify changes in machine behavior and investigate potential mechanical problems.

Flexible Sensor-Head Configuration

The sensor-head diameter is listed as optional. This makes it especially important to confirm the required mechanical configuration when specifying the product for an installation.

Technical FAQs

1. What is the Epro PR9670/110-100?

The PR9670/110-100 is an Epro eddy-current sensor designed for non-contact measurement applications involving conductive metallic targets. It can be used as part of an industrial machinery monitoring arrangement.

2. What measurement principle does it use?

It uses the eddy-current principle. An electromagnetic field interacts with a conductive target, and changes in the electrical response are used to determine changes in the distance between the probe and target.

3. What can this sensor measure?

Depending on the complete sensor and monitoring-system configuration, eddy-current sensing can be used for displacement, shaft position, and vibration-related measurements.

4. Does the sensor contact the rotating shaft?

No. Eddy-current measurement is non-contact. The probe is installed near the conductive target, and the system detects changes in the gap without requiring the probe to touch the shaft.

5. Is the sensor-head diameter fixed?

The supplied product information identifies the sensor-head diameter as optional. Confirm the required diameter and mechanical configuration before ordering.

6. What is the shipping weight?

The supplied shipping weight is 3 kg. This figure includes the shipping basis provided for the listing and should not be treated as the sensor’s net weight.

7. Does the sensor work directly with a PLC?

A compatible signal-conditioning or monitoring arrangement is generally required to process the probe signal. PLC integration depends on the available output interface of the connected monitoring equipment.

8. Can it be used for turbine and compressor monitoring?

Eddy-current sensors are commonly used in rotating machinery monitoring applications. Suitability for a specific turbine or compressor depends on the probe configuration, operating conditions, mounting arrangement, and monitoring-system compatibility.

9. Can the PR9670/110-100 replace another PR9670 model?

Not automatically. Confirm the complete model number, probe-head dimensions, cable arrangement, measurement characteristics, and signal-conditioning requirements before replacing another model.

10. What should be checked before purchasing?

Confirm the model number, sensor-head diameter, mounting configuration, cable and connector details, compatible conditioner, product condition, and shipping contents. For replacement projects, comparing the existing sensor with the proposed unit is especially important.

Procurement and Maintenance Recommendations

When purchasing the Epro PR9670/110-100, begin by identifying the exact sensor configuration required by the existing machinery monitoring system.

The optional sensor-head diameter should be confirmed before placing an order. Also verify the mounting thread, cable arrangement, connector type, and compatible signal conditioner. These details are important because an apparently similar probe may not provide the correct mechanical or electrical interface.

For replacement applications, obtain the complete model number from the existing sensor label or equipment documentation. Compare the replacement unit with the original installation rather than relying only on the product-family name.

When receiving the sensor, inspect the probe body, sensing tip, cable, connectors, and mounting threads. Check for visible mechanical damage and confirm that the supplied accessories match the order.

During maintenance, keep the probe and its mounting location clean. Inspect cable routing and connector condition, and look for signs of looseness, abrasion, or excessive heat exposure. Follow the manufacturer’s procedures for calibration and electrical testing.

The 3 kg shipping weight should be used only as a logistics reference. If accurate net weight or package dimensions are required for inventory or transportation records, verify them with the supplier.

Conclusion

The Epro PR9670/110-100 Eddy Current Sensor is an industrial non-contact sensing component intended for applications involving conductive metallic targets and machinery displacement monitoring. Its eddy-current measurement principle makes it relevant to rotating equipment where shaft position and movement need to be observed without direct mechanical contact.

For successful installation and replacement, the most important considerations are the optional sensor-head diameter, mechanical mounting configuration, cable arrangement, and compatibility with the associated signal-conditioning equipment. Confirming these details helps ensure that the sensor can be integrated correctly into an existing machinery monitoring system.



Related Products

Get the latest price? We will reply as soon as possible (within 12 hours)

No:77501