• GE IC200ALG326D Analog Output Module
  • GE IC200ALG326D Analog Output Module
  • GE IC200ALG326D Analog Output Module
  • GE IC200ALG326D Analog Output Module
Product Overview The GE IC200ALG326D VersaMax Analog Output Module is an industrial programmable logic controller (PLC) I/O component designed to convert digital control commands into analog current sig……
GE IC200ALG326D Analog Output Module
  • GE
  • IC200ALG326D
  • Analog Output Module
  • USA
  • 110 x 66.8 x 50 mm
  • 0.19 kg
  • Xiamen, China
  • New & In Stock
  • T/T, PayPal, Western Union
  • 1 Year
  • 1-3 Working Days
  • DHL, UPS, TNT, FedEx and EMS.
  • 24-Hour Service
  • COO
  • 29

Our advantage

GE IC200ALG326D Analog Output Module

Global Logistics

We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.

GE IC200ALG326D Analog Output Module

Brand new and original

Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.

GE IC200ALG326D Analog Output Module

24-hour service

We provide 7*24 hours service to our customers. We will be there whenever you need us.

GE IC200ALG326D Analog Output Module

Price advantage

All our products are priced very favorably because we have our own warehouse and supply.


Company Information
E-mail [email protected]
Mobile +8615980777398
Whatsapp +8615980777398
WeChat 15980777398

Product Overview

The GE IC200ALG326D VersaMax Analog Output Module is an industrial programmable logic controller (PLC) I/O component designed to convert digital control commands into analog current signals. As part of the GE Fanuc VersaMax automation platform, it provides eight analog output channels for controlling field devices that require current-based reference signals.

Analog output modules are essential in industrial control systems because many field devices cannot be controlled directly through digital on/off signals. Equipment such as control valves, actuator positioners, variable-speed drive interfaces, and process regulators often require continuously adjustable signals. The IC200ALG326D provides this interface by converting controller output data into proportional current signals.

This module provides eight single-ended current-sourcing outputs arranged in one group. Its default output range is 4–20 mA, while a 0–20 mA range can also be selected through jumper configuration. With 13-bit resolution, the module supports graduated output commands for applications requiring adjustable process control.

The IC200ALG326D uses an external 18–30 V DC field power supply for its output circuits and draws up to 50 mA from the 5 V backplane supply. Its maximum output update rate is 15 ms. Two LED indicators, FLD PWR and OK, help maintenance personnel identify field power and backplane operating status.

Within a VersaMax PLC installation, the module receives output data through the system backplane and generates corresponding analog current signals for connected devices. Its eight channels allow several control loops or actuators to be managed through one module, helping reduce the number of separate analog output modules required in a suitable system configuration.

The IC200ALG326D is particularly relevant to process automation, equipment control, and distributed I/O applications where multiple current-controlled devices must respond to PLC commands. Correct jumper settings, field power wiring, load compatibility, and channel configuration are essential for reliable operation.

Technical Specifications

Parameter Specification
Brand GE Fanuc / GE
Manufacturer General Electric
Product Series VersaMax
Model IC200ALG326D
Product Type Analog Current Output Module
Module Function Digital-to-Analog Current Output
Resolution 13-bit
Number of Channels 8
Channel Configuration 8 single-ended outputs, one group
Default Output Range 4–20 mA
Alternative Output Range 0–20 mA
Output Configuration Jumper selectable
External Field Power 18–30 V DC
Maximum Backplane Current 50 mA at 5 V DC
Maximum Output Update Rate 15 ms
Typical Accuracy at 25°C ±0.3% of full scale
Maximum Accuracy at 25°C ±0.5% of full scale
LED Indicators FLD PWR, OK
Output Type Current-sourcing
Isolation User-side circuits to logic and frame ground, subject to specified ratings
Mounting VersaMax carrier-based installation
Dimensions 110 × 66.8 × 50 mm
Weight 0.19 kg
Typical Applications Valve control, actuator control, process regulation, analog references

Note: Dimensions exclude the height of the carrier and mating connectors. Confirm the exact revision documentation and installation requirements before system design.

Function and Working Principle

The primary function of the IC200ALG326D is to convert digital values from a VersaMax controller into analog current signals. These signals provide continuous control references to external equipment.

1. Digital-to-Analog Conversion

The PLC executes its control program and calculates output values based on process conditions, sensor feedback, operator commands, and programmed control logic.

The resulting digital values are transferred to the analog output module through the VersaMax backplane. The module converts these values into corresponding current signals.

For example, a PLC may calculate a valve opening command based on the difference between a measured process temperature and its target value. The IC200ALG326D converts the controller’s output command into a current signal that the valve positioner can interpret.

This conversion allows digital control systems to operate equipment that requires continuously variable analog commands.

2. Eight Independent Output Channels

The module provides eight single-ended analog current output channels arranged in one group.

Each channel can be assigned to a different field device or control function. A single module may therefore provide output references for several control valves, actuator positioners, or other current-controlled equipment.

The eight-channel configuration can help reduce cabinet space and simplify I/O planning when compared with installations that require several smaller output modules.

Because the outputs are arranged in one group, engineers should review the module’s wiring and isolation characteristics before connecting devices with different grounding or electrical reference requirements.

3. 4–20 mA Current Output

The default operating range is 4–20 mA, a widely used signal standard in industrial process automation.

In a typical control application:

  • 4 mA represents the lower end of the configured operating range.
  • 12 mA represents approximately the midpoint.
  • 20 mA represents the upper end.

For example, a control valve may interpret 4 mA as a minimum opening command and 20 mA as a maximum opening command. The actual relationship depends on the field device configuration.

The 4 mA lower limit is often called a live zero. It allows the receiving instrument to distinguish a valid low-level signal from a zero-current condition, although additional diagnostics are required to identify wiring faults reliably.

4. Selectable 0–20 mA Output

The module can also be configured for a 0–20 mA output range through the appropriate jumper arrangement.

This option may be useful when interfacing with equipment designed for a zero-based current reference. The selected range must match the receiving device’s input configuration.

The range and output behavior should be documented during commissioning so that future maintenance personnel can understand how each channel is intended to operate.

5. Output State Configuration

The IC200ALG326D supports jumper configuration for output behavior when backplane power or communication is interrupted.

Depending on the selected configuration, outputs can be set to hold their last values or return to the configured low-end default. External field power must remain available for the outputs to maintain the applicable behavior.

This feature is important in systems where an unexpected output change could affect equipment operation. Engineers should choose the appropriate behavior according to the process risk assessment and the receiving device’s requirements.

Role in Industrial Control Systems

The IC200ALG326D provides the analog output interface between the VersaMax PLC and external control equipment. It allows digital control logic to influence physical process variables through current-based commands.

PLC Output Processing

A VersaMax controller processes input information and executes the application program. The controller then generates digital output values for the analog output module.

The IC200ALG326D converts these values into current signals that connected field devices can use.

This arrangement supports distributed control architectures in which the PLC handles decision-making while I/O modules provide the electrical interface to field equipment.

Control Valve Operation

Control valves are common examples of equipment controlled through 4–20 mA signals. A PLC can calculate the required valve position according to flow, pressure, or temperature conditions.

The analog output module converts the controller’s command into a current reference for the valve positioner.

Correct signal scaling and calibration are necessary to ensure that the PLC’s requested position corresponds to the intended valve movement.

Variable-Speed Drive References

Some variable-speed drives accept analog current references for speed or process control. The IC200ALG326D can provide a suitable current output where the receiving drive supports the selected signal range and electrical interface.

For example, a PLC may calculate a pump speed reference based on process demand. The analog output module converts this value into a current signal for the drive.

The drive’s input impedance, signal scaling, and grounding arrangement should be checked before connection.

Distributed I/O Applications

The VersaMax platform supports distributed automation architectures. Analog output modules can be installed within an appropriate I/O station to provide control signals near the equipment they operate.

This arrangement can simplify field wiring and support modular system expansion. The selected VersaMax carrier, power supply, controller or network interface, and configuration software must all be compatible with the module.

Industrial Applications

The IC200ALG326D is suitable for applications that require multiple analog current output signals from a PLC-based control system.

1. Process Control Valves

Industrial process systems frequently use control valves to regulate fluid flow, pressure, and temperature.

The IC200ALG326D can provide current references to compatible valve positioners. The PLC adjusts the output according to process measurements and control algorithms.

With eight channels, the module can support several valve-control points within a suitable VersaMax installation.

2. Pump Control Systems

Pumping systems may use analog references to regulate motor speed through a compatible variable-speed drive.

A PLC can calculate the required speed based on flow demand, tank level, or pressure feedback. The module converts the command into a current signal for the drive.

This approach supports adjustable pump operation and can help match equipment output to changing process requirements.

3. Industrial Fan and Blower Control

Fans and blowers may require adjustable-speed operation to maintain ventilation, airflow, or process conditions.

Where a drive accepts a compatible current reference, the IC200ALG326D can provide the PLC-generated speed command.

The actual control arrangement depends on the drive’s analog input specifications and the application’s electrical design.

4. Temperature Regulation

Industrial heating and cooling systems often use analog output signals to control valves, dampers, or power-control equipment.

A PLC can calculate the required control output based on temperature measurements. The analog module then supplies a proportional current signal to the receiving device.

Accurate scaling and calibration help maintain stable temperature regulation.

5. Material Processing Equipment

Manufacturing equipment may use analog signals to regulate speed, flow, pressure, or actuator position.

The IC200ALG326D can provide several current output channels for these functions, allowing multiple devices to receive commands from one VersaMax I/O station.

6. Water and Wastewater Treatment

Water-treatment facilities use analog control signals for chemical dosing pumps, flow-control valves, and other process equipment.

A PLC can adjust these devices according to measured process values. The analog output module provides the current reference required by compatible field equipment.

The signal range, device input characteristics, and required fail-state behavior should be verified for each application.

Installation and System Integration

Correct installation is essential for reliable analog signal transmission and stable operation of the VersaMax system.

1. Verify VersaMax System Compatibility

Before installation, confirm that the IC200ALG326D is supported by the selected VersaMax carrier and controller or network interface.

Check the system’s hardware configuration, module identification, firmware requirements, and available backplane power capacity.

The module should be installed in the position specified by the system design and the applicable GE Fanuc documentation.

2. Provide External Field Power

The analog output circuits require an external 18–30 V DC field power supply.

Verify the power supply’s output voltage, current capacity, polarity, and grounding arrangement before connecting the module.

The field power supply must be capable of supporting the connected output loads. Undersized power supplies or unstable DC voltage can cause unreliable output operation.

3. Configure the Output Range

Select the required output range using the documented jumper arrangement.

The default range is 4–20 mA, while 0–20 mA is also supported. Confirm the receiving device’s required signal range before changing the configuration.

Record the jumper settings in the electrical drawings and commissioning documentation.

4. Configure Output Failure Behavior

Determine whether the application requires outputs to hold their last state or return to the configured default when backplane power or communication is interrupted.

This choice should be based on the process design, equipment requirements, and risk assessment.

A safe-state requirement should not be assumed from the module’s default behavior alone. Where a process requires safety-rated shutdown, use an appropriately designed safety system.

5. Connect Field Devices

Connect the eight output channels according to the module’s terminal and wiring documentation.

Use suitable cables and observe the recommended separation between analog signal wiring and high-voltage or high-current conductors.

Check the input resistance and signal requirements of every receiving device. Confirm that the output load is within the module’s electrical limits.

6. Verify LED Indicators

The module provides two LED indicators:

  • FLD PWR: Indicates the presence of field power.
  • OK: Indicates that backplane power is present.

These indicators provide a basic visual reference during installation and troubleshooting. They do not replace software diagnostics, signal measurement, or a complete functional test.

7. Commission Each Output Channel

After installation, test each channel independently.

Verify the configured output range, PLC scaling, channel assignment, wiring polarity, and measured current. Confirm that each field device responds correctly to the intended command.

Document the final channel assignments and calibration values for future maintenance.

Compatible System Components

The IC200ALG326D is part of the GE Fanuc VersaMax I/O platform. Its operation depends on compatible system hardware and correctly configured field devices.

Component Function Integration Considerations
VersaMax PLC CPU Executes control logic and generates output data Confirm compatibility with the module and system configuration
VersaMax carrier Provides the mechanical and electrical mounting interface Select the correct carrier and connector arrangement
VersaMax power supply Provides system power Check backplane power capacity and system requirements
Network Interface Unit Supports distributed I/O communication Confirm compatibility and firmware requirements
18–30 V DC field power supply Supplies external output-circuit power Verify voltage, current capacity, and polarity
Control valve positioner Receives current commands for valve positioning Confirm 4–20 mA or 0–20 mA input compatibility
Variable-speed drive Uses an analog reference for speed or process control Check input range, scaling, and grounding
PLC programming software Configures hardware and application logic Confirm support for the installed VersaMax hardware
Terminal and wiring accessories Connect field devices to module outputs Follow the specified terminal and wiring arrangement

The table describes typical system components and field devices. They are not necessarily supplied with the IC200ALG326D.

Alternative Models and Replacement Considerations

Several VersaMax modules provide related analog output functions. However, they differ in channel count, signal type, resolution, and electrical configuration.

Model General Function Main Difference
IC200ALG320 4-channel, 12-bit analog current output Fewer channels and different resolution
IC200ALG321 4-channel, 12-bit analog voltage output Voltage rather than current output
IC200ALG322 4-channel, 12-bit bipolar voltage output Supports a different voltage signal range
IC200ALG325 8-channel, 13-bit analog voltage output Voltage output configuration
IC200ALG326 8-channel, 13-bit analog current output Same base module family; check revision
IC200ALG327 12-channel, 13-bit analog voltage output Higher channel count and voltage output
IC200ALG328 12-channel, 13-bit analog current output Higher channel count and current output
IC200ALG331 4-channel isolated voltage/current output Different isolation and signal configuration

These models should not be treated as automatic substitutes. Before replacing the IC200ALG326D, verify:

  • Number of required output channels.
  • Current or voltage signal requirements.
  • 4–20 mA or 0–20 mA configuration.
  • Resolution and accuracy requirements.
  • External field power requirements.
  • Carrier and backplane compatibility.
  • Output default and hold-last-state behavior.
  • Hardware revision and controller support.
  • Terminal wiring and field-device compatibility.

A replacement with a similar product name may have a different electrical interface. Always compare the full model number and technical documentation.

Key Advantages

Eight Current Output Channels

The module provides eight analog current outputs in one VersaMax I/O module, supporting multiple control points within a compact installation.

13-Bit Resolution

Its 13-bit output resolution supports graduated analog commands for process equipment requiring adjustable current references.

Flexible Signal Range

The module supports both 4–20 mA and 0–20 mA output ranges through the documented jumper configuration.

Standard Industrial Signal Interface

Current outputs are widely used in process automation and are compatible with many industrial control valves, positioners, and drive interfaces.

External Field Power

The 18–30 V DC field power arrangement provides a dedicated supply for the output circuits, allowing the field power design to be considered separately from the backplane supply.

Output State Configuration

The jumper-selectable output behavior provides options for maintaining the last output state or returning to the configured default under specified power or communication interruption conditions.

Straightforward Status Monitoring

The FLD PWR and OK LEDs provide visual indications of field power and backplane power, supporting basic maintenance checks.

VersaMax Platform Integration

The module is designed for use within the VersaMax automation architecture, making it relevant to existing installations that use compatible GE Fanuc controllers and I/O hardware.

Technical FAQs

1. What is the GE IC200ALG326D?

The IC200ALG326D is a GE Fanuc VersaMax analog current output module. It converts digital output commands from a compatible PLC or network interface into analog current signals for external field devices.

2. How many output channels does the IC200ALG326D provide?

It provides eight single-ended current output channels arranged in one group.

3. What is the default output range?

The default output range is 4–20 mA. The module can also be configured for 0–20 mA using the appropriate jumper arrangement.

4. What is the resolution of this module?

The module is specified as a 13-bit analog current output module. Its resolution supports graduated output commands across the selected signal range.

5. What external power supply does it require?

The output circuits require an external 18–30 V DC field power supply. The supply must have sufficient capacity for the connected output loads.

6. What is the maximum output update rate?

The specified maximum update rate is 15 ms. Actual system response also depends on controller execution, communication, configuration, and connected equipment.

7. What do the FLD PWR and OK LEDs indicate?

FLD PWR indicates that field power is present, while OK indicates that backplane power is present. These indicators help technicians perform initial status checks.

8. Can the module control a 4–20 mA valve positioner?

Yes, provided the valve positioner accepts a compatible current input and the wiring, output scaling, and electrical load meet the module’s requirements.

9. What happens if backplane communication is interrupted?

The module supports jumper-selectable output behavior. Depending on the configuration, outputs can hold their last states or return to the configured low-end default, provided the external field power remains available.

10. Can the IC200ALG326D be replaced with the IC200ALG328?

Not automatically. The IC200ALG328 is a related 12-channel current output model, while the IC200ALG326D provides eight channels. The channel count, wiring, configuration, carrier compatibility, and system support must be checked before substitution.

Procurement and Maintenance Recommendations

When purchasing the GE IC200ALG326D, verify the complete catalog number and hardware revision. The revision suffix is important for identifying the exact module and checking its compatibility with the installed VersaMax system.

For new, surplus, or refurbished modules, inspect the housing, terminal connections, carrier interface, and visible electronic components. Confirm that the FLD PWR and OK indicators operate correctly during a suitable functional test.

Before placing the module into service, confirm the external field power supply, output range, jumper configuration, and field-device requirements. If the module is replacing an existing unit, document the original channel assignments and output scaling before removing it.

During routine maintenance, inspect wiring connections, field power stability, terminal condition, and analog signal quality. Periodically verify the current measured at the receiving device against the PLC command. This helps identify wiring resistance, grounding problems, incorrect scaling, or field-device faults.

Keep a record of the module revision, system configuration, jumper settings, and connected equipment. This information can reduce troubleshooting time and simplify future replacement work.

Conclusion

The GE IC200ALG326D VersaMax Analog Output Module is an eight-channel, 13-bit current output component designed for PLC-based industrial control systems. It provides selectable 4–20 mA and 0–20 mA signals, operates with an external 18–30 V DC field power supply, and supports analog control of compatible valves, actuators, drives, and process equipment.

Its eight-channel design, selectable output behavior, and VersaMax platform integration make it a useful component in existing industrial automation installations. For reliable operation, engineers should verify the hardware revision, field power supply, jumper configuration, output scaling, and compatibility of all connected devices before installation or replacement.

 



Related Products

Get the latest price? We will reply as soon as possible (within 12 hours)

No:77501