The Schneider Electric TSXETZ410 Ethernet Module is an industrial communication gateway designed for the Modicon TSX Micro automation platform. Belonging to Schneider Electric’s FactoryCast Gateway range, this module provides Ethernet connectivity between PLC systems, industrial computers, operator stations, and other networked devices.
In industrial automation, communication between controllers and supervisory systems is essential for monitoring production, exchanging process information, and maintaining coordinated equipment operation. The TSXETZ410 helps connect legacy Modicon TSX Micro installations to Ethernet-based networks while also supporting serial communication services.
The module supports 10/100 Mbps Ethernet communication and a maximum serial modem link speed of 56 kbps. Its communication capabilities include Uni-Telway and Modbus-related services, allowing it to support data exchange between compatible automation devices and external systems.
The TSXETZ410 is powered by an external 24 V DC supply and features several physical communication interfaces, including an Ethernet RJ45 connector, an RS485 auxiliary port, an RS232 modem connection, and a Mini-DIN terminal port. These interfaces provide flexibility when connecting PLC equipment, engineering terminals, and remote communication devices.
The FactoryCast gateway functions extend beyond basic network connectivity. Depending on the configured system, the module can support PLC data access, communication diagnostics, remote terminal functions, and program-related services.
Because the TSXETZ410 is a discontinued product, it is particularly relevant to maintenance teams supporting existing Modicon TSX Micro installations. When purchasing a replacement, engineers should verify the complete model number, connector arrangement, firmware and configuration requirements, and compatibility with the installed PLC system.
| Parameter | Specification |
|---|---|
| Brand | Schneider Electric |
| Product Model | TSXETZ410 |
| Product Family | Modicon TSX Micro |
| Product Range | FactoryCast Gateway |
| Product Type | Ethernet Module / Communication Gateway |
| Network Standard | Ethernet IEEE 802.3 |
| Ethernet Transmission Rate | 10/100 Mbps |
| Serial Modem Link Speed | Up to 56 kbps |
| Rated Supply Voltage | 24 V DC |
| Supply Voltage Limits | 19.2–30 V DC |
| Power Dissipation | 2.4–4 W |
| Current Consumption | 50–200 mA at 24 V DC |
| Ethernet Interface | RJ45 |
| Auxiliary Communication | RS485 / RJ45 |
| Serial Modem Interface | RS232 / 9-pin SUB-D |
| Terminal Interface | Mini-DIN |
| Communication Services | Uni-Telway, Modbus-related services, Ethernet services |
| Network Topology | Star and tree Ethernet |
| Maximum Ethernet Cable Distance | 100 m between terminal device and hub |
| Status Indicators | RUN, ERR, RX/TX |
| Mounting | Mounting plate |
| Width | 39.83 mm |
| Height | 151.5 mm |
| Depth | 116.7 mm |
| Dimensions | 39.83 × 151.5 × 116.7 mm |
| Weight | 0.28 kg |
| Product Lifecycle | Discontinued |
Specifications should be checked against the exact hardware revision and the requirements of the installed Modicon TSX Micro system.
The TSXETZ410 operates as a communication gateway between a compatible PLC installation and Ethernet-based industrial networks. It provides communication interfaces and gateway services that allow information to move between different devices and network environments.
The module provides a 10/100 Mbps Ethernet interface through an RJ45 connector. This allows a compatible PLC system to exchange information with industrial computers, supervisory systems, and other Ethernet-connected equipment.
Ethernet communication is useful in applications where production information must be available to several devices. For example, a supervisory computer may collect PLC data for process monitoring, while an engineering workstation uses the network for diagnostics or program-related tasks.
The TSXETZ410 supports industrial Ethernet communication based on IEEE 802.3 standards. Network configuration, addressing, and connected-device compatibility must be established during commissioning.
The FactoryCast gateway provides functions for accessing PLC data and variables. This capability helps external systems obtain process information from the connected automation platform.
Depending on the application configuration, accessible data may include machine status, operating values, production information, and diagnostic variables.
This makes the module useful in installations where operators or engineers need to observe PLC information without relying exclusively on a local programming terminal.
The TSXETZ410 supports communication services associated with Uni-Telway and Modbus. These services help connect compatible devices and exchange industrial control information.
Uni-Telway is associated with Schneider Electric’s legacy automation systems, while Modbus provides a widely used method of exchanging data between industrial devices.
The actual communication method depends on the connected equipment, network configuration, and supported services. Engineers should confirm protocol compatibility before connecting third-party devices.
In addition to Ethernet communication, the TSXETZ410 supports an RS232 serial connection for modem-based communication. The maximum serial modem link speed is specified as 56 kbps.
This function can be useful in legacy installations where remote communication is required through compatible modem infrastructure.
Because modem technology and telecommunications infrastructure have changed significantly, the availability and suitability of the remote communication path must be evaluated separately from the module itself.
The module includes three local status indicators:
These indicators help maintenance personnel identify basic operating and communication conditions during commissioning and troubleshooting.
The TSXETZ410 provides a communication link between Modicon TSX Micro controllers and external networked devices. It can be used in installations where PLC data must be accessed by engineering workstations, operator systems, or supervisory applications.
The module supports communication between compatible TSX Micro PLC systems and external devices. This helps integrate controller information into a wider automation network.
For example, a PLC may control a production machine while the TSXETZ410 provides a communication path for supervisory monitoring and engineering access.
Supervisory Control and Data Acquisition systems collect information from industrial equipment and present it to operators. Through compatible network services, the TSXETZ410 can help make PLC data available to a supervisory environment.
Typical information may include equipment status, process values, alarms, and operating conditions. The SCADA software and communication configuration must support the services used by the PLC installation.
Engineering personnel may use network communication to access PLC information, perform diagnostics, and support maintenance activities.
The module’s communication services can reduce dependence on direct local connections in appropriately configured systems. However, access permissions, network security, and the limitations of the legacy PLC platform must be considered.
Many industrial facilities continue operating equipment built around earlier PLC generations. Replacing an entire control system can involve substantial engineering work, production interruption, and validation.
The TSXETZ410 provides an Ethernet gateway option for compatible legacy Modicon TSX Micro installations, helping maintain communication with external systems while the existing controller remains in operation.
The TSXETZ410 is intended for communication tasks in industrial automation systems using compatible Modicon TSX Micro equipment.
Production lines often contain several PLC-controlled machines that must exchange information with supervisory systems.
The TSXETZ410 can provide an Ethernet communication path for accessing PLC data and supporting monitoring functions. This helps production personnel observe machine conditions and coordinate maintenance activities.
Packaging systems may use PLCs to control conveyors, filling equipment, labeling stations, and other machine functions.
Where a compatible TSX Micro controller is installed, the TSXETZ410 can help connect the controller to an industrial Ethernet network for supervisory data access and engineering communication.
Industrial process equipment often requires continuous monitoring of operating conditions. PLC data may be collected by supervisory systems to help operators understand equipment status and identify abnormal conditions.
The TSXETZ410 can support this communication architecture when the controller, software, and network services are compatible.
Water-treatment and wastewater installations may contain distributed pumping, filtration, and monitoring equipment.
A compatible TSX Micro installation can use the TSXETZ410 to provide Ethernet communication for PLC data access and diagnostics. The suitability of the module depends on the control architecture and the communication requirements of the facility.
Some legacy automation systems require communication between local PLC equipment and remote engineering or supervisory locations.
The module’s Ethernet and serial modem communication capabilities can support suitable remote-access arrangements. Actual remote connectivity depends on the available network infrastructure and the configuration of external communication equipment.
Maintenance teams may need to monitor PLC status, inspect communication conditions, and access controller information during troubleshooting.
The TSXETZ410 can provide a communication interface for these activities, helping support continued operation of compatible legacy equipment.
Correct installation is important for reliable communication and stable operation.
Before installing the TSXETZ410, confirm that the existing controller belongs to a compatible Modicon TSX Micro system.
Check the PLC model, hardware configuration, supported communication services, and software requirements. Do not assume that the module can be installed in an arbitrary Modicon rack or used with every Schneider Electric PLC family.
The module requires an external 24 V DC supply. The documented supply limits are 19.2–30 V DC.
The power source should have sufficient capacity for the module and any other connected equipment. Check polarity, wiring, grounding, and terminal connections before energizing the unit.
Use the RJ45 Ethernet interface to connect the module to a compatible industrial network.
The Ethernet cable should be suitable for the installation environment. Confirm the network speed, addressing configuration, topology, and connected equipment.
The documented maximum Ethernet cable distance is 100 m between the terminal device and hub. For longer distances, an appropriately designed network infrastructure may be required.
Where RS232 or RS485 communication is required, confirm the connected device’s interface, pin assignment, communication parameters, and supported protocol.
Avoid assuming that all serial interfaces use identical wiring or settings. Incorrect connections can prevent communication or cause equipment problems.
After powering the module, inspect the RUN, ERR, and RX/TX indicators.
The indicators provide useful initial information about module operation and communication activity. If an error condition is indicated, check the power supply, wiring, network configuration, and connected equipment.
Set up the required network parameters and communication services according to the system design.
Verify that the PLC data required by the supervisory or engineering application is accessible. Test communication in both directions where the application requires bidirectional data exchange.
Legacy industrial communication modules may not provide the same security capabilities as newer network equipment.
Where remote access or connections to enterprise networks are required, use appropriate network segmentation, access controls, firewalls, and secure remote-access arrangements. Avoid exposing legacy PLC communication services directly to public networks.
The TSXETZ410 operates as part of a broader automation communication system. Its suitability depends on the PLC platform, communication interfaces, network infrastructure, and software configuration.
| Component | Function | Integration Considerations |
|---|---|---|
| Modicon TSX Micro PLC | Executes machine-control logic | Verify exact controller compatibility |
| Industrial Ethernet switch | Connects Ethernet devices | Supports network distribution and topology |
| Industrial Ethernet cable | Provides physical network connection | Use suitable RJ45 cabling and observe distance limits |
| 24 V DC power supply | Powers the gateway module | Maintain voltage within 19.2–30 V DC |
| SCADA workstation | Collects and displays PLC data | Confirm supported communication services |
| HMI or operator station | Provides process information and operator interaction | Verify protocol and data-access compatibility |
| Engineering computer | Supports diagnostics and maintenance | Confirm software and communication configuration |
| RS232 modem | Supports compatible serial modem communication | Verify modem type and telecommunications infrastructure |
| RS485 equipment | Supports compatible serial communication | Check wiring, addressing, and protocol settings |
| Modbus-compatible device | Exchanges industrial data | Confirm supported Modbus services and configuration |
The components listed above are examples of equipment that may be used in a complete installation. They are not necessarily included with the TSXETZ410.
The TSXETZ410 is discontinued and has no direct replacement designated by Schneider Electric. A replacement should therefore be selected according to the communication requirements and the existing PLC architecture.
| Alternative or Related Option | Considerations |
|---|---|
| Schneider Electric TSXETZ510 | Related FactoryCast Ethernet gateway; compare functionality and configuration before considering substitution |
| Schneider Electric TSX Micro communication options | May support selected legacy communication requirements, depending on controller compatibility |
| Schneider Electric Modicon M-series Ethernet solutions | May be considered for a wider control-system upgrade |
| Schneider Electric Modicon M340 Ethernet communication modules | Suitable for certain modernization projects, but require platform-level compatibility assessment |
| Industrial Ethernet gateway | May provide protocol conversion or network connectivity when properly engineered |
Before selecting an alternative, review the following:
A newer Ethernet module should not be treated as a direct replacement simply because it provides an RJ45 connector. Differences in PLC architecture, communication services, configuration software, and protocol support may require engineering changes.
The TSXETZ410 provides an Ethernet communication option for compatible Modicon TSX Micro installations, helping connect legacy automation equipment to networked systems.
Its Ethernet, RS232, RS485, and Mini-DIN connections provide several communication paths for compatible equipment.
The module supports PLC data access and communication-related services that can help engineering and supervisory systems interact with the controller.
Uni-Telway and Modbus-related services support communication with compatible industrial devices and software environments.
RUN, ERR, and RX/TX indicators provide basic information for commissioning and maintenance.
With dimensions of 39.83 × 151.5 × 116.7 mm and a supplied weight of 0.28 kg, the module is suitable for installations where mounting space is limited.
The module remains relevant to facilities that need to maintain existing TSX Micro systems and preserve their communication capabilities.
The TSXETZ410 is a FactoryCast Ethernet gateway module designed for compatible Modicon TSX Micro automation systems. It provides Ethernet and serial communication capabilities for PLC data access and industrial networking.
It supports 10/100 Mbps Ethernet communication. Its serial modem link supports a maximum speed of 56 kbps.
The module uses an external 24 V DC supply. Its specified supply voltage limits are 19.2–30 V DC.
The module provides an Ethernet RJ45 connector, an RS485 auxiliary RJ45 interface, an RS232 9-pin SUB-D modem connection, and a Mini-DIN terminal port.
Yes. Its documented communication services include Modbus-related services as well as Uni-Telway communication. Confirm the exact service and configuration required by the connected equipment.
It can provide an Ethernet communication path for accessing PLC data in a compatible system. Successful SCADA integration depends on the PLC configuration, supported communication services, and supervisory software.
RUN indicates operating status, ERR provides error indication, and RX/TX shows communication activity. These indicators are useful for initial troubleshooting.
No. Schneider Electric lists the TSXETZ410 as discontinued. Buyers should verify the availability and condition of new-old-stock, refurbished, or used units before ordering.
The TSXETZ510 is a related FactoryCast gateway, but it should not be assumed to be a direct replacement. Compare the communication functions, PLC compatibility, configuration requirements, and system application before substitution.
Confirm the complete TSXETZ410 model number, physical condition, connector integrity, power requirements, available test information, and compatibility with the installed TSX Micro controller. For critical applications, request functional testing and confirm warranty or return conditions.
When sourcing the Schneider Electric TSXETZ410, begin by confirming the complete product reference and the PLC system in which it will operate. The module is discontinued, so availability may depend on remaining inventory, surplus stock, or refurbished equipment.
For used or refurbished units, request clear photographs of the front panel, connectors, mounting plate, and product label. Inspect the RJ45, RS232, RS485, and Mini-DIN connections for physical damage. Where possible, obtain evidence of power-up and communication testing.
Before installation, verify the 24 V DC supply, PLC compatibility, network settings, and communication services. Record the original configuration so that it can be restored if the module is replaced.
During maintenance, inspect cable connections, power terminals, network indicators, and the surrounding cabinet environment. Keep connectors clean and ensure that cables are correctly secured.
For long-term modernization planning, evaluate the communication requirements of the existing TSX Micro system and determine whether maintaining the legacy gateway or migrating to a newer PLC platform is more appropriate. Consider protocol compatibility, engineering resources, cybersecurity, production downtime, and the cost of replacing associated control equipment.
The Schneider Electric TSXETZ410 Ethernet Module is a FactoryCast communication gateway designed for compatible Modicon TSX Micro PLC systems. Supporting 10/100 Mbps Ethernet, serial modem communication up to 56 kbps, and industrial communication services such as Uni-Telway and Modbus, it provides a way to connect legacy automation equipment with external networked systems.
Its multiple communication interfaces, 24 V DC supply, and PLC data-access capabilities make it relevant to industrial maintenance and legacy-system support. Since the module is discontinued, accurate identification, condition verification, and system compatibility checks are essential when purchasing or planning a replacement.