The GE IC200UAA007 VersaMax Micro PLC Controller is a compact programmable logic controller designed for small-scale industrial automation and machine-control applications. Developed within the GE Fanuc VersaMax Micro product family, this controller combines processing functions, AC digital inputs, AC outputs, and an integrated power supply in a compact unit.
Unlike modular PLC systems that require separate CPU, power supply, and I/O modules, the IC200UAA007 integrates its primary control functions into one controller. This design helps reduce installation space and simplifies the hardware configuration of machines with a relatively fixed number of input and output points.
The IC200UAA007 provides 28 discrete I/O points, consisting of 16 AC inputs and 12 AC outputs. Its input circuits are designed for 120 V AC signals, while its output circuits support 120/240 V AC loads. The controller operates from a nominal 100–240 V AC power supply, making it suitable for compatible industrial electrical installations.
The controller can process signals from field devices such as pushbuttons, limit switches, and AC-compatible proximity switches. Its outputs can control suitable external loads, including selected indicators, contactor coils, and other AC-operated devices within the specified electrical limits.
The IC200UAA007 is particularly relevant to compact machine automation, equipment sequencing, and legacy control-system maintenance. Its integrated design can simplify control-panel construction where the required I/O configuration matches the controller’s fixed hardware arrangement.
When selecting this model, engineers should pay attention to its AC-only input configuration and triac-based AC outputs. It does not provide high-speed counter, PWM, or pulse-train functionality. These limitations are important when evaluating the controller for applications involving high-speed sensing, pulse-based motion control, or DC field signals.
| Parameter | Specification |
|---|---|
| Brand | GE Fanuc |
| Manufacturer | General Electric / GE Intelligent Platforms |
| Model | IC200UAA007 |
| Product Series | VersaMax Micro |
| Product Type | 28-Point Micro PLC Controller |
| Controller Architecture | Integrated Micro PLC |
| Total I/O Points | 28 |
| Digital Inputs | 16 AC inputs |
| Input Voltage | 120 V AC nominal |
| Digital Outputs | 12 AC outputs |
| Output Type | Triac |
| Output Voltage | 120/240 V AC |
| Maximum Resistive Output Current | 0.5 A per point |
| Power Supply | Integrated AC power supply |
| Supply Voltage Range | 100–240 V AC nominal operating range |
| Supply Frequency | 50/60 Hz |
| High-Speed Counter | Not supported |
| PWM Function | Not supported |
| Pulse Train Output | Not supported |
| Typical Scan Rate | Approximately 1.1 ms/K for Boolean logic |
| Dimensions Provided | 150 × 90 × 76 mm |
| Weight Provided | 0.58 kg |
| Typical Application | Compact industrial machine control |
Note: Dimensions and weight are supplied listing values. Manufacturer documentation lists the dimensions as 150 mm wide × 90 mm high × 76 mm deep and a typical weight of approximately 0.60 kg. Verify the actual unit before shipping or installation.
The IC200UAA007 operates as an integrated PLC controller. It receives electrical signals from field devices, processes the programmed control logic, and updates its output states according to the application requirements.
The controller provides 16 AC input points designed for 120 V AC field signals.
These inputs can receive signals from compatible industrial devices, including:
The input circuits detect changes in the connected electrical signals and convert them into information that the PLC program can process.
The IC200UAA007 uses AC input circuits. They must not be connected to DC signal sources as a substitute for DC-compatible input modules.
The controller provides 12 AC output points using triac switching technology.
These outputs can control compatible AC loads within the specified electrical ratings. The outputs are arranged in isolated groups, allowing different groups to be supplied from different phases or from the same AC supply, subject to the wiring requirements.
Each output point has a maximum resistive load rating of 0.5 A. The output commons are protected by replaceable 3.15 A fuses, and RC snubbers are provided to help manage transient electrical noise.
External power must be supplied to operate the connected loads. The controller’s output circuits should not be treated as an independent power source for field equipment.
The integrated processor executes the user-defined control program. Depending on the application, the program can include:
The controller repeatedly reads input conditions, processes the programmed logic, and updates the output states.
Its typical Boolean logic scan rate is approximately 1.1 ms per 1,000 Boolean instructions, although actual execution time depends on the program structure and system configuration.
The IC200UAA007 includes an AC power supply for the controller. Its nominal operating input range is 100–240 V AC.
This integrated power arrangement reduces the need for a separate controller power-supply module. However, external field-device power and output-load power must still be provided where required by the electrical design.
The VersaMax Micro controller supports timing functions and a time-of-day clock. These capabilities can be used for scheduled operations, time-based sequences, and application-specific control routines.
For applications that depend on accurate timekeeping, the controller’s documented clock accuracy and battery-backup requirements should be considered during maintenance planning.
The IC200UAA007 can serve as the main control unit in compact automation systems. It combines input acquisition, logic processing, and output switching, making it suitable for machines that do not require a large modular PLC architecture.
In a standalone machine, the controller can monitor operator commands and equipment conditions before executing the programmed sequence.
For example, a machine may use pushbuttons to initiate a cycle, limit switches to confirm mechanical positions, and AC outputs to operate external control devices.
The controller processes these signals according to the programmed logic and coordinates the sequence of machine operations.
The 16 AC inputs provide connections for compatible field signals. They can be used to monitor machine position, equipment status, and operator commands.
Because the inputs are designed for AC signals, engineers must confirm that the field devices provide the correct signal type and voltage before wiring them to the controller.
The 12 AC triac outputs allow the PLC to switch compatible AC loads. These outputs can be used in equipment-control circuits where the load current and electrical characteristics remain within the specified limits.
For loads that exceed the direct output rating, an appropriately rated interposing relay or contactor should be used.
The controller can operate as part of a wider machine-control arrangement that includes sensors, contactors, motor starters, safety devices, and operator panels.
The exact integration method depends on the installed hardware and the communication capabilities required by the application. Communication and programming connections should be verified against the controller documentation.
The GE IC200UAA007 is designed for compact automation systems with AC field signals and relatively simple discrete control requirements.
Packaging equipment often uses switches and sensors to monitor product position, machine status, and operating sequences.
The IC200UAA007 can process compatible AC input signals and control external AC devices as part of a programmed packaging sequence.
Typical control tasks may include:
Small conveyor systems can use PLC logic to coordinate motor starters, position switches, and operator commands.
The controller can monitor compatible AC signals and switch external AC control loads. Where the conveyor motor requires variable-speed operation, a separate drive may be incorporated into the overall control architecture.
The controller can be used in machines with a fixed number of digital input and output points.
Examples include small assembly machines, auxiliary production equipment, and simple material-handling systems.
Its integrated I/O arrangement is useful where the control requirements remain within the available 16-input and 12-output configuration.
Small pumping and ventilation systems may require basic start/stop control, status monitoring, and interlocking.
The IC200UAA007 can process compatible AC control signals and operate suitable external control devices. Motor power should normally be switched through appropriately rated motor starters or contactors rather than directly through the PLC’s low-current triac outputs.
Certain utility systems require simple control sequences for fans, pumps, auxiliary equipment, and electrical devices.
The controller may be suitable where the field signals and output loads match its AC electrical specifications and where the required control complexity fits its capabilities.
Correct installation is essential for electrical safety, reliable signal processing, and stable PLC operation.
The IC200UAA007 uses an integrated AC power supply with a nominal operating range of 100–240 V AC.
Before energizing the controller, confirm the supply voltage, frequency, protective devices, and grounding arrangement.
The supply must remain within the manufacturer’s permitted limits. Incorrect voltage can damage the controller or cause unstable operation.
The controller provides 16 AC input points designed for 120 V AC signals.
Before connecting field devices, verify:
The AC inputs cannot be used with DC power sources. If the application requires 24 V DC input signals, a suitable DC-input controller or I/O solution should be selected.
The 12 outputs use triac switching technology and support compatible AC loads.
The maximum resistive load current is 0.5 A per point. Output-load selection must also account for inrush current, inductive characteristics, leakage current, and the ratings of the output group.
For higher-current loads or equipment with demanding switching characteristics, use a properly rated interposing relay or contactor.
The PLC’s integrated power supply supports controller operation. It does not mean that all connected field loads can be powered directly from the controller.
External power must be provided for connected output loads according to the electrical design. Ensure that each output group is wired correctly and protected as specified.
The controller must be programmed using a compatible GE Fanuc VersaMax Micro programming environment.
Before commissioning, verify the controller model, program compatibility, communication connection, and software version.
The application program should be tested to confirm that all input conditions, output responses, timers, interlocks, and fault-handling routines operate as intended.
After installation, perform a systematic inspection and test procedure.
Recommended checks include:
Never connect field devices or perform wiring work while the equipment is energized unless an approved procedure specifically permits it.
The IC200UAA007 is an integrated PLC, but it may be used with additional components to form a complete machine-control system.
| Component | Function | Integration Considerations |
|---|---|---|
| AC pushbuttons | Provide operator commands | Must match the AC input voltage requirements |
| AC limit switches | Detect mechanical position | Confirm contact ratings and input compatibility |
| AC proximity switches | Detect objects or machine conditions | Verify output signal type and voltage |
| Interposing relays | Switch loads beyond PLC output capability | Select coil voltage and contact ratings carefully |
| Contactors | Control motors and larger electrical loads | Use appropriate coil suppression and protection |
| Circuit breakers or fuses | Provide electrical protection | Select according to wiring and equipment ratings |
| Operator panel | Provides machine commands and status display | Confirm the available communication interface |
| Programming cable | Connects the controller to a programming computer | Use the appropriate supported cable and software |
| Control cabinet | Provides mounting and environmental protection | Allow suitable wiring access and ventilation |
The components listed above are examples of equipment that may be used in an application. They are not necessarily supplied with the IC200UAA007.
When replacing the IC200UAA007, the most important factors are the I/O signal types, number of points, supply voltage, output technology, and program compatibility.
| Alternative Model | Description | Replacement Considerations |
|---|---|---|
| GE IC200UAA003 | 14-point VersaMax Micro PLC with AC I/O | Fewer I/O points; verify application requirements |
| GE IC200UAR028 | 28-point VersaMax Micro PLC with AC inputs and relay outputs | Different output technology and contact ratings |
| GE IC200UDD110 | 28-point VersaMax Micro PLC with DC I/O | Not a direct substitute for AC field wiring |
| GE IC200UDR005 | 28-point VersaMax Micro PLC with DC inputs and relay outputs | Requires review of signal and output compatibility |
| GE IC200UAL006 | VersaMax Micro controller with mixed I/O functions | Different I/O configuration and electrical requirements |
Before selecting a replacement, compare:
A controller with the same number of I/O points may still require substantial wiring and program changes if its input or output technology differs.
The controller combines 16 AC inputs and 12 AC outputs in one compact unit, reducing the need for separate I/O modules in compatible applications.
Its integrated power supply simplifies the controller’s basic electrical arrangement and reduces the need for a separate PLC power-supply module.
The compact form factor makes the IC200UAA007 suitable for smaller control cabinets and machines with limited installation space.
The 16 AC inputs support compatible 120 V AC field devices, making the controller useful in applications designed around AC control signals.
The 12 triac outputs provide switching capability for compatible AC loads within the specified electrical ratings.
The integrated PLC processor supports programmed logic, timing, sequencing, and machine-control functions.
The VersaMax Micro family is used in legacy automation installations. Maintaining the correct model and configuration is important when servicing existing machines or sourcing replacement equipment.
The GE IC200UAA007 is a 28-point VersaMax Micro PLC controller. It combines 16 AC inputs, 12 AC outputs, an integrated processor, and an AC power supply.
It provides 16 AC digital inputs and 12 AC digital outputs, for a total of 28 I/O points.
Its digital input circuits are designed for 120 V AC signals. They cannot be used with DC input signals.
The controller uses 12 triac-based AC outputs. The outputs support compatible 120/240 V AC loads, with a maximum resistive load current of 0.5 A per point.
Yes. It includes an AC power supply for controller operation, with a nominal operating range of 100–240 V AC.
No. The IC200UAA007 does not provide high-speed counter, PWM, or pulse-train operation.
The PLC can control motor starters or contactors through suitable output circuits, but its triac outputs should not be used to supply motor power directly. Use appropriately rated motor-control equipment.
Not directly through its 120 V AC input circuits. A compatible DC-input PLC or suitable signal-interface equipment is required.
The supplied product listing weight is 0.58 kg. Manufacturer documentation lists a typical module weight of approximately 0.60 kg.
Confirm the complete catalog number, input and output configuration, electrical ratings, physical condition, and program compatibility. Also check whether the replacement requires changes to field wiring or control logic.
When sourcing the GE IC200UAA007, confirm the complete model number and ensure that the product is the 28-point AC I/O version. Similar VersaMax Micro controllers may have different input voltages, output technologies, and power requirements.
For used or refurbished equipment, request clear photographs of the front label, terminal areas, and overall housing. Check for damaged terminals, cracked insulation, corrosion, and signs of overheating. Where possible, request functional testing of the input and output circuits.
For installation and maintenance, keep the control cabinet clean and dry. Inspect terminal connections, field wiring, fuses, and grounding arrangements according to the applicable maintenance schedule.
Maintain a backup of the PLC program and document any changes made during commissioning or troubleshooting. Before replacing the controller, verify that the existing program and programming environment are compatible with the replacement hardware.
Because the IC200UAA007 uses AC inputs and triac outputs, replacement planning should pay particular attention to field signal voltage and output-load characteristics. A controller with DC I/O or relay outputs may require wiring modifications even if its physical dimensions are similar.
The GE IC200UAA007 VersaMax Micro PLC Controller is a compact 28-point programmable controller designed for industrial applications requiring 16 AC inputs and 12 AC outputs. With its integrated processor and 100–240 V AC power supply, it provides a self-contained control solution for compatible machinery and equipment.
Its AC input circuits, triac-based outputs, and compact design make it suitable for selected machine-control applications. However, the absence of high-speed counters, PWM, and pulse-train functions must be considered when evaluating it for more demanding automation tasks.
For maintenance and replacement projects, checking the exact I/O configuration, supply requirements, program compatibility, and physical condition helps ensure that the IC200UAA007 can be integrated safely and reliably into the intended control system.