Product Overview The Schneider Electric HMIGTO1310 is a compact operator terminal in the Harmony GTO series, built for machines that need a local touchscreen interface without dedicating cabinet space t……
Schneider HMIGTO1310 Advanced Touchscreen Panel
  • Schneider
  • HMIGTO1310
  • Advanced Touchscreen Panel
  • France
  • 132 × 42 × 106 mm
  • 0.4 kg
  • Xiamen, China
  • New & In Stock
  • T/T, PayPal, Western Union
  • 1 Year
  • 1-3 Working Days
  • DHL, UPS, TNT, FedEx and EMS.
  • 24-Hour Service
  • COO
  • 3

Our advantage

Schneider HMIGTO1310 Advanced Touchscreen Panel

Global Logistics

We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.

Schneider HMIGTO1310 Advanced Touchscreen Panel

Brand new and original

Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.

Schneider HMIGTO1310 Advanced Touchscreen Panel

24-hour service

We provide 7*24 hours service to our customers. We will be there whenever you need us.

Schneider HMIGTO1310 Advanced Touchscreen Panel

Price advantage

All our products are priced very favorably because we have our own warehouse and supply.


Company Information
E-mail [email protected]
Mobile +8615980777398
Whatsapp +8615980777398
WeChat 15980777398

Product Overview

The Schneider Electric HMIGTO1310 is a compact operator terminal in the Harmony GTO series, built for machines that need a local touchscreen interface without dedicating cabinet space to a larger HMI. Its 3.5-inch color TFT display presents operating values, alarm messages, machine status, and configured control screens at 320 × 240 pixel QVGA resolution.

A key distinction between the HMIGTO1310 and the closely related HMIGTO1300 is Ethernet connectivity. The HMIGTO1310 includes a 10BASE-T/100BASE-TX Ethernet port alongside a configurable RS-232C/RS-485 serial interface. This makes it suitable for installations where the operator panel needs to communicate with a PLC over Ethernet or connect to compatible serial equipment. The serial communication method is selected according to the application configuration.

Consider a compact assembly machine with a PLC connected to the plant’s automation network. The HMIGTO1310 can display cycle status, production counts, operating parameters, and fault messages while allowing operators to acknowledge alarms or adjust permitted settings. Ethernet can support communication with a compatible controller, while the serial interface offers an alternative for supported devices that use a serial protocol.

The terminal uses a nominal 24 V DC supply and supports Vijeo Designer for HMI project development. The application determines the displayed screens, data objects, alarm behavior, and operator commands. Its 96 MB application memory supports the specified terminal configuration, while USB interfaces allow compatible peripheral and service operations.

Because the HMIGTO1310 combines Ethernet with serial communication, it can accommodate different control-system layouts. However, the available interfaces do not automatically make every PLC or protocol compatible. The controller driver, network settings, serial parameters, and application project must be configured for the connected equipment.

When replacing an existing unit, the main checks are the original project, communication method, panel cutout, power supply, and controller configuration. Although the HMIGTO1300 shares the same general display format, its lack of Ethernet makes it unsuitable as a direct substitute where the existing application depends on the HMIGTO1310’s network interface.


Technical Specifications

Parameter Specification
Manufacturer Schneider Electric
Model HMIGTO1310
Product Family Harmony GTO
Product Type Advanced Touchscreen Panel
Display Type Backlit Color TFT LCD
Display Size 3.5 inches
Display Resolution 320 × 240 pixels, QVGA
Display Colors 65,536
Touch Panel Resistive analog touchscreen
Touch-Sensitive Resolution 1024 × 1024
Function Keys 6 programmable keys, F1–F6
Application Memory 96 MB
Rated Supply Voltage 24 V DC
Supply Voltage Limits 19.2–28.8 V DC
Maximum Power Consumption 9.6 W
Ethernet Interface 1 × RJ45, 10BASE-T/100BASE-TX
COM1 Interface RS-232C/RS-485, configurable by software, RJ45
COM2 Interface Not available
USB Type-A 1 × USB 2.0 host
USB Mini-B 1 × USB 2.0
Memory Card Interface Not available
Configuration Software Vijeo Designer
Supported Communication Protocols Modbus TCP/IP and supported serial PLC protocols, subject to driver configuration
Backlight Service Life Approximately 50,000 hours
Brightness Adjustment 16 levels
Front Protection IP65, NEMA 4X for indoor use, subject to installation conditions
Rear Protection IP20
Operating Temperature 0–55°C
Storage Temperature -20–60°C
Dimensions 132 × 42 × 106 mm
Weight 0.4 kg

Product Features

  • 3.5-inch color touchscreen: Displays essential machine information and configured operator controls in a compact format.
  • QVGA display resolution: Presents numerical values, status indicators, alarms, and graphical screens at 320 × 240 pixels.
  • Ethernet connectivity: Supports 10BASE-T/100BASE-TX communication with compatible controllers and industrial networks.
  • Configurable serial interface: Allows COM1 to operate in RS-232C or RS-485 mode according to the application configuration.
  • Six programmable function keys: Provides physical access to application-defined operations.
  • 96 MB application memory: Supports the specified HMI application configuration.
  • Vijeo Designer support: Allows engineers to configure screens, communication drivers, data objects, and operator actions.
  • USB connectivity: Includes Type-A and Mini-B interfaces for supported peripheral and service functions.
  • Industrial front-panel protection: The front meets IP65 and NEMA 4X indoor-use requirements when installed under the specified conditions.

Working Principle

The HMIGTO1310 acts as the operator interface between a person and a PLC-controlled machine. Its internal processor runs the configured HMI application, while the touchscreen and function keys provide access to operating information and permitted commands.

A typical communication path is:

PLC or Controller → Ethernet or Serial Communication → HMIGTO1310 → Touchscreen → Operator

During operation, the terminal exchanges process data with the controller using the driver configured in Vijeo Designer. The application presents this information as operating values, machine-state indicators, alarms, and graphical controls. When an operator touches a control or presses a programmed function key, the application sends the corresponding request through the configured communication channel.

The Ethernet interface supports 10BASE-T/100BASE-TX connections. With a compatible controller and configured protocol, the terminal can exchange data over the industrial network without requiring a direct serial link. Network addressing and controller communication settings must match the plant’s configuration.

COM1 supports either RS-232C or RS-485, selected through software configuration. Since these interfaces use different electrical arrangements and wiring requirements, the selected mode must correspond to the connected device. The serial protocol and communication parameters must also match the controller.

Vijeo Designer determines how the terminal behaves. The project defines the screens, controller addresses, displayed variables, alarms, and permitted operator actions. For a replacement terminal, engineers should verify the project version and communication drivers rather than assuming that an existing application will operate unchanged.

The HMIGTO1310 does not replace the PLC’s control logic. The controller remains responsible for machine sequencing, interlocks, and physical outputs. The HMI provides the visual interface and passes operator requests to the controller through the configured communication path.


Role in an Industrial HMI Architecture

The HMIGTO1310 occupies the local operator-interface layer of a machine control system. Its Ethernet and configurable serial interface allow it to fit different communication arrangements, provided the selected controller and protocol are supported.

PLC / Machine Controller → Ethernet or Serial Network → HMIGTO1310 → Operator

System Element Function
HMIGTO1310 Terminal Displays machine information and processes operator input
Touchscreen Provides graphical access to configured controls and status screens
Function Keys F1–F6 Execute application-defined operations
PLC or Machine Controller Executes machine logic and exchanges process data
Ethernet Interface Supports network communication over 10BASE-T/100BASE-TX
COM1 Serial Interface Supports RS-232C or RS-485, depending on software configuration
Vijeo Designer Project Defines screens, data objects, alarms, and communication settings
USB Interfaces Support compatible peripheral and service functions

Industrial Applications

Application Typical Use
Compact Packaging Machines Displaying production counts, machine status, and alarm messages
Automated Assembly Stations Presenting cycle information and operator controls
Labeling Equipment Showing operating settings, fault messages, and production data
Pump Control Panels Displaying operating states and process values supplied by a PLC
Conveyor Systems Monitoring run status, transfer sequences, and equipment alarms
Industrial Test Equipment Presenting test parameters, measured values, and completion status
Networked Machine Panels Connecting the HMI to a compatible PLC over Ethernet
Serial-Controlled Equipment Communicating with supported devices through configurable RS-232C or RS-485
Machine Retrofit Projects Replacing a compatible terminal while retaining the established HMI workflow
Maintenance Stations Providing local access to diagnostic screens and equipment status

Installation and Maintenance

  1. Verify the model: Confirm that HMIGTO1310 is the required terminal, particularly where the application depends on Ethernet communication.
  2. Check the panel cutout: Match the mounting opening and clearance to the applicable installation drawings before fitting the terminal.
  3. Confirm the DC supply: Verify the nominal 24 V DC supply and ensure that the input remains within the specified 19.2–28.8 V range.
  4. Inspect the front-panel seal: Clean the mounting surface and check the gasket arrangement to maintain the specified front protection.
  5. Configure the Ethernet connection: Verify the network cable, IP address, subnet settings, and controller communication configuration.
  6. Select the serial interface mode: Determine whether COM1 must operate as RS-232C or RS-485 and configure it accordingly.
  7. Check serial wiring: Confirm connector assignments, cable condition, shielding, and the electrical requirements of the connected device.
  8. Review function-key assignments: Verify that F1–F6 perform the intended actions in the application project.
  9. Validate the HMI project: Check the Vijeo Designer project version, controller driver, screen configuration, and target model before transferring the application.
  10. Test communication: Confirm that controller values update correctly over the selected interface and that permitted commands reach the intended device.
  11. Inspect touchscreen operation: Test screen navigation, displayed values, alarm messages, and operator input after installation.
  12. Record commissioning details: Document the HMI model, project version, IP settings, serial configuration, key assignments, and functional test results.

Compatible System Components

Component Function
Compatible Modicon PLCs Execute machine control logic and exchange process data with the HMI
Ethernet-Compatible Controllers Communicate through the HMIGTO1310’s Ethernet interface using a supported protocol
PLCs with RS-232C Interfaces Connect through COM1 when it is configured for RS-232C
PLCs and Devices with RS-485 Interfaces Connect through COM1 when it is configured for RS-485
Vijeo Designer Software Configures HMI screens, communication drivers, alarms, and operator functions
USB Type-A Peripherals Support compatible USB host functions
USB Mini-B Connection Supports applicable service and device communication functions
24 V DC Power Supply Provides the required operating power
Industrial Ethernet Cable Connects the terminal to compatible controllers and industrial networks
Compatible Serial Cable Connects the terminal to supported serial equipment
Panel Mounting Hardware Secures the terminal and supports the required front-panel sealing arrangement

Recommended Related Models

Model Product Type Selection Consideration
Schneider HMIGTO1300 Advanced Touchscreen Panel Similar 3.5-inch display format, but without Ethernet; check communication requirements carefully
Schneider HMIGTO2300 Advanced Touchscreen Panel Offers a 5.7-inch display but does not include Ethernet
Schneider HMIGTO2310 Advanced Touchscreen Panel Provides a larger display with Ethernet and serial communication
Schneider HMIGTO3510 Advanced Touchscreen Panel Offers a 7-inch display for applications requiring more screen space
Schneider HMIGTO4310 Advanced Touchscreen Panel Provides a larger VGA display and Ethernet connectivity

Key Advantages

  • Combines a 3.5-inch touchscreen with six programmable function keys.
  • Supports Ethernet communication with compatible controllers.
  • Provides a configurable RS-232C/RS-485 serial interface.
  • Supports HMI project development through Vijeo Designer.
  • Offers front-panel IP65 and NEMA 4X indoor-use protection under specified installation conditions.
  • Fits compact operator stations requiring both local display and network connectivity.

Technical FAQs

What is the main difference between the HMIGTO1310 and HMIGTO1300?

The HMIGTO1310 includes a 10BASE-T/100BASE-TX Ethernet interface and a configurable RS-232C/RS-485 COM1 port. The HMIGTO1300 has no Ethernet interface and uses separate RS-232C and RS-485 serial ports. This distinction can determine whether an existing network-based HMI project can be retained without changing the communication architecture.

Can COM1 on the HMIGTO1310 be used for both RS-232C and RS-485 simultaneously?

No. COM1 is configurable for RS-232C or RS-485 operation. The selected mode must match the connected device and the project’s communication settings; it is not a pair of independent serial ports.

What needs to be checked when transferring a Vijeo Designer project to this terminal?

Verify the target model, project version, controller driver, Ethernet or serial settings, screen configuration, and function-key assignments. Back up the original project and test communication with the connected PLC before placing the machine back into service.

Is the HMIGTO1310 suitable for an application that needs a larger process overview?

It can display configured process information within its 3.5-inch QVGA screen, but the available viewing area may be restrictive for complex diagrams or many simultaneous values. A larger Harmony GTO model may be more appropriate if the operator needs to see several process areas at once.