• ABB Bailey SPTPS13 Symphony Plus Harmony Rack Turbine Protection Module
  • ABB Bailey SPTPS13 Symphony Plus Harmony Rack Turbine Protection Module
  • ABB Bailey SPTPS13 Symphony Plus Harmony Rack Turbine Protection Module
  • ABB Bailey SPTPS13 Symphony Plus Harmony Rack Turbine Protection Module
Product Overview The ABB Bailey SPTPS13 is a multifunction turbine speed detection and protection module for the Symphony Plus Harmony Rack control platform. It combines functions previously handled by ……
ABB Bailey SPTPS13 Symphony Plus Harmony Rack Turbine Protection Module
  • ABB Bailey
  • SPTPS13
  • Turbine Protection Module
  • Sweden (SE)
  • 350 × 25 × 150 mm
  • 0.33 kg
  • Xiamen, China
  • New & In Stock
  • T/T, PayPal, Western Union
  • 1 Year
  • 1-3 Working Days
  • DHL, UPS, TNT, FedEx and EMS.
  • 24-Hour Service
  • COO
  • 5

Our advantage

ABB Bailey SPTPS13 Symphony Plus Harmony Rack Turbine Protection Module

Global Logistics

We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.

ABB Bailey SPTPS13 Symphony Plus Harmony Rack Turbine Protection Module

Brand new and original

Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.

ABB Bailey SPTPS13 Symphony Plus Harmony Rack Turbine Protection Module

24-hour service

We provide 7*24 hours service to our customers. We will be there whenever you need us.

ABB Bailey SPTPS13 Symphony Plus Harmony Rack Turbine Protection Module

Price advantage

All our products are priced very favorably because we have our own warehouse and supply.


Company Information
E-mail [email protected]
Mobile +8615980777398
Whatsapp +8615980777398
WeChat 15980777398

Product Overview

The ABB Bailey SPTPS13 is a multifunction turbine speed detection and protection module for the Symphony Plus Harmony Rack control platform. It combines functions previously handled by three separate module types: SPTPS02, SPFCS01 and SPTSA01. This consolidation allows compatible turbine control installations to retain their existing system architecture while using one module family for several related applications.

The SPTPS13 is used in turbine control systems where speed monitoring and protective responses must be handled independently of routine plant control. In a steam turbine installation, for example, an overspeed condition can require a rapid protective response to prevent the turbine from accelerating beyond its permitted operating range. Depending on the configured operating mode, the module can support overspeed protection, turbine trip, electro-hydraulic control protection and power-load imbalance functions.

A key feature of the SPTPS13 is its use of interchangeable application adapter boards. The TPS, FCS and TSA adapters configure the module for the corresponding legacy application and determine the applicable I/O channel mapping. This makes the exact module configuration important during replacement: installing the correct SPTPS13 without the appropriate adapter and termination arrangement may not reproduce the intended application.

The module interfaces with compatible Harmony Rack termination units, including TPTU02, NTDI01 and NTDI02, depending on the selected function. In TPS mode, three SPTPS13 modules can connect to one TPTU02 termination unit through standard NKTU01 cables, supporting a triple-modular-redundant protection arrangement.


Technical Specifications

Parameter Specification
Manufacturer ABB Bailey
Model / Part Number SPTPS13
Product Family Symphony Plus Harmony Rack
Product Type Turbine Protection Module
Primary Functions Turbine speed detection and protection
Supported Application Modes TPS, FCS and TSA
Application Adapter Boards TPS, FCS and TSA
Compatible Termination Units TPTU02, NTDI01 and NTDI02, depending on application
TPS Mode Configuration Three modules connected to one TPTU02
Redundancy in TPS Mode Triple modular redundancy
Legacy Module Replacements SPTPS02, SPFCS01 and SPTSA01
Supported TPS Function Codes FC 145, FC 79, FC 83 and FC 84
Supported FCS Function Code FC 145
Supported TSA Function Code FC 103
Dimensions 350 × 25 × 150 mm
Weight 0.33 kg

Product Features

  • Multifunction turbine protection: Consolidates speed detection and protection applications previously handled by multiple Harmony Rack module types.
  • Application-specific adapters: Uses TPS, FCS or TSA adapter boards to configure the applicable operating mode and I/O mapping.
  • Overspeed protection: Supports protective action when turbine speed reaches the configured threshold.
  • Turbine trip capability: Supports the protective response used to shut turbine valves when a trip condition occurs.
  • Power-load imbalance monitoring: Compares electrical load output with turbine mechanical load input to identify conditions associated with potential overspeed.
  • Redundant protection architecture: Supports triple-modular-redundant operation in the specified TPS configuration.
  • Termination unit compatibility: Interfaces with TPTU02, NTDI01 or NTDI02 according to the selected application.
  • Legacy system integration: Supports replacement of SPTPS02, SPFCS01 and SPTSA01 in compatible Harmony Rack installations.

Working Principle

The SPTPS13 receives turbine-related input signals through its configured termination and adapter arrangement. Its onboard processor evaluates the incoming data against the configured protection functions and initiates the corresponding output response when a qualifying condition occurs.

In TPS mode, the module participates in a dedicated turbine protection arrangement. Three SPTPS13 modules connect to a TPTU02 termination unit, and the protection logic uses a two-out-of-three voting arrangement for applicable protective functions. This allows the system to evaluate redundant inputs and determine whether a protective action should be initiated without relying on the normal Symphony Plus controller or data highways for the time-critical protection decision.

The module can support several distinct responses. Overspeed protection can initiate action intended to control an overspeed event, while the turbine trip function can operate the shutdown arrangement. Electro-hydraulic control protection addresses the relevant hydraulic control system, and power-load imbalance monitoring compares electrical output with the turbine’s mechanical load input to anticipate certain overspeed conditions.

The operating behavior depends on the installed adapter board, configured function code, termination unit and associated protective equipment. During a replacement, these elements must be checked together to ensure that the new module reproduces the required protection logic and signal mapping.


Role in a Symphony Plus Harmony Rack Turbine Control System

The SPTPS13 operates at the turbine protection layer of the Harmony Rack architecture. It processes turbine-related signals and supports protective outputs through the configured termination unit, while the broader control system handles normal plant monitoring and control functions.

Turbine Speed and Process Signals → Compatible Termination Unit → SPTPS13 Protection Logic → Protective Output Circuit → Turbine Valve or Shutdown Mechanism

System Component Function Relationship to the SPTPS13
SPTPS13 Turbine Protection Module Evaluates turbine-related inputs and executes configured protection functions Performs the assigned speed detection and protection tasks
TPTU02 Termination Unit Provides the termination and relay interface for the applicable TPS configuration Connects the SPTPS13 modules to the relevant input and output circuits
NTDI01 / NTDI02 Termination Units Provide compatible termination arrangements for supported applications Interface with the module according to the selected configuration
TPS Adapter Board Configures the module for turbine protection applications Establishes the TPS operating mode and associated I/O mapping
FCS Adapter Board Configures the module for the corresponding legacy application Supports the SPFCS01 replacement arrangement
TSA Adapter Board Configures the module for the corresponding legacy application Supports the SPTSA01 replacement arrangement
NKTU01 Cable Connects modules to the TPTU02 termination unit in the specified TPS arrangement Carries the required module-to-termination connections
Turbine Speed Sensors Supply turbine speed information Provide input data used by the configured protection functions
Protective Relays and Hydraulic Manifold Execute protective actions on the turbine Respond to outputs generated through the configured protection circuit
Symphony Plus Control System Handles broader plant control and monitoring Integrates the turbine subsystem into the overall automation environment

Industrial Applications

Application Typical Equipment Role of the SPTPS13
Steam Turbine Protection Steam turbines in power generation plants Supports speed monitoring and configured turbine protection functions
Gas Turbine Control Industrial gas turbine installations Processes turbine-related signals for the applicable protection arrangement
Hydro Turbine Protection Hydroelectric generating equipment Supports protection functions appropriate to the configured application
Turbine Overspeed Protection Turbine speed sensing and trip circuits Evaluates speed-related inputs and initiates configured protective responses
Electro-Hydraulic Control Protection Hydraulic turbine valve control systems Supports the EHC protection function in applicable configurations
Power Generation Control Generator and turbine control systems Supports power-load imbalance monitoring where configured
Legacy Harmony Rack Modernization Existing SPTPS02, SPFCS01 or SPTSA01 installations Consolidates compatible legacy applications into the SPTPS13 module family
Distributed Control System Integration Symphony Plus Harmony Rack installations Connects turbine-specific protection functions with the broader plant control architecture

Installation and Maintenance

  1. Verify the module reference: Confirm that SPTPS13 is the correct replacement for the existing turbine protection, FCS or TSA application.
  2. Identify the operating mode: Determine whether the installation uses TPS, FCS or TSA mode before transferring the module.
  3. Check the adapter board: Verify that the required TPS, FCS or TSA adapter is installed and matches the intended application.
  4. Confirm the termination unit: Identify whether the system uses TPTU02, NTDI01 or NTDI02 and check the applicable interface requirements.
  5. Isolate the equipment: Follow the approved shutdown, electrical isolation and turbine protection maintenance procedures before removing the module.
  6. Inspect the rack and connectors: Check the module position, mating connectors and associated termination hardware for damage or contamination.
  7. Verify the function code: Confirm the configured Harmony function code and ensure that it matches the application being maintained.
  8. Check the cable arrangement: In TPS mode, verify the specified NKTU01 connections and the arrangement of the three protection modules.
  9. Review I/O mapping: Compare the input and output assignments with the installed adapter configuration and the plant’s protection documentation.
  10. Verify protective output circuits: Check the associated relay, trip and hydraulic manifold interfaces according to the approved commissioning procedure.
  11. Perform functional testing: Test the applicable protection functions, including speed-related responses and trip logic, using the site’s approved test procedures before returning the turbine to service.
  12. Record the configuration: Document the module reference, adapter type, function code, termination unit, cable arrangement and completed test results.

Compatible System Components

Component Function Compatibility Consideration
ABB Bailey SPTPS02 Earlier turbine protection module Legacy application that SPTPS13 can replace in a compatible configuration
ABB Bailey SPFCS01 Earlier turbine-related control module Requires the corresponding FCS application configuration and adapter
ABB Bailey SPTSA01 Earlier turbine synchronization-related module Requires the corresponding TSA application configuration and adapter
ABB Bailey TPTU02 Turbine protection termination unit Used with SPTPS13 in the specified TPS arrangement
ABB Bailey NTDI01 Termination unit Supported for applicable SPTPS13 configurations
ABB Bailey NTDI02 Termination unit Supported for applicable SPTPS13 configurations
ABB Bailey NKTU01 Module-to-termination cable Used to connect SPTPS13 modules to TPTU02 in TPS mode
TPS Adapter Board Application adapter Configures the module for the TPS operating mode
FCS Adapter Board Application adapter Configures the module for the FCS operating mode
TSA Adapter Board Application adapter Configures the module for the TSA operating mode
Turbine Speed Sensors Detect turbine rotational speed Must match the configured input and termination arrangement
Turbine Protective Relays Operate the designated protective circuits Must match the installed trip and protection architecture

Recommended Related Models

Model / Product Product Type Relationship Selection Consideration
ABB Bailey SPTPS02 Turbine Protection Module Legacy module replaced by SPTPS13 in compatible applications Verify the original TPS function code and termination arrangement
ABB Bailey SPFCS01 Turbine Control Module Legacy module consolidated into the SPTPS13 family Confirm the FCS application and required adapter
ABB Bailey SPTSA01 Turbine Synchronization Module Legacy module consolidated into the SPTPS13 family Confirm the TSA application and function code
ABB Bailey TPTU02 Turbine Protection Termination Unit Compatible termination unit for TPS mode Verify the existing relay and module connection arrangement
ABB Bailey NTDI01 Termination Unit Supported termination option for applicable configurations Match the termination unit to the intended application
ABB Bailey NTDI02 Termination Unit Supported termination option for applicable configurations Verify signal and interface requirements
ABB Bailey NKTU01 Module-to-Termination Cable Used in the specified TPS module arrangement Check cable routing and the three-module configuration

Key Advantages

  • Consolidates three compatible legacy Harmony Rack module applications.
  • Supports turbine speed detection and multiple protection functions.
  • Allows application configuration through dedicated adapter boards.
  • Supports triple-modular-redundant protection in the specified TPS arrangement.
  • Integrates with compatible termination units and existing Harmony Rack architecture.

Technical FAQs

How does the SPTPS13 replace SPTPS02, SPFCS01 and SPTSA01?

The SPTPS13 supports three application modes using the TPS, FCS and TSA adapter boards. Each adapter establishes the relevant operating mode and I/O mapping, so the original module function and associated termination arrangement must be identified before replacement.

Why are three SPTPS13 modules used in the TPS configuration?

The specified TPS arrangement uses three modules connected to one TPTU02 termination unit. This supports triple-modular redundancy and two-out-of-three voting for applicable protective functions, allowing the protection logic to evaluate redundant inputs before initiating a protective action.

Which termination unit should be used with the SPTPS13?

The supported termination arrangement depends on the selected application. TPTU02 is used in the specified TPS configuration, while NTDI01 and NTDI02 are supported for applicable configurations. The adapter, function code and existing wiring must be checked together.

What should be tested after replacing an SPTPS13?

Verify the installed adapter, configured function code, input mapping, termination connections and protective output circuits. Functional testing should cover the protection functions used by the actual turbine application, following the plant’s approved commissioning and safety procedures.



Related Products

Get the latest price? We will reply as soon as possible (within 12 hours)

No:77501