• Foxboro P0926TM Standard 200 Series AC Input Power Cable
  • Foxboro P0926TM Standard 200 Series AC Input Power Cable
  • Foxboro P0926TM Standard 200 Series AC Input Power Cable
  • Foxboro P0926TM Standard 200 Series AC Input Power Cable
Product Overview The Foxboro P0926TM Standard 200 Series AC Input Power Cable Assembly is used in compatible Foxboro industrial automation and process control installations where a dedicated cable is re……
Foxboro P0926TM Standard 200 Series AC Input Power Cable
  • Foxboro
  • P0926TM
  • AC Input Power Cable
  • USA
  • 1.2 meters
  • 3 kg
  • Xiamen, China
  • New & In Stock
  • T/T, PayPal, Western Union
  • 1 Year
  • 1-3 Working Days
  • DHL, UPS, TNT, FedEx and EMS.
  • 24-Hour Service
  • COO
  • 5

Our advantage

Foxboro P0926TM Standard 200 Series AC Input Power Cable

Global Logistics

We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.

Foxboro P0926TM Standard 200 Series AC Input Power Cable

Brand new and original

Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.

Foxboro P0926TM Standard 200 Series AC Input Power Cable

24-hour service

We provide 7*24 hours service to our customers. We will be there whenever you need us.

Foxboro P0926TM Standard 200 Series AC Input Power Cable

Price advantage

All our products are priced very favorably because we have our own warehouse and supply.


Company Information
E-mail [email protected]
Mobile +8615980777398
Whatsapp +8615980777398
WeChat 15980777398

Product Overview

The Foxboro P0926TM Standard 200 Series AC Input Power Cable Assembly is used in compatible Foxboro industrial automation and process control installations where a dedicated cable is required for the AC power input connection. It belongs to the power-entry wiring arrangement rather than the downstream cables that distribute power from a supply to modular baseplates.

The P0926TM has a cable length of 1.2 meters. This length accommodates cabinet layouts in which the relevant power connection points are separated by mounting rails, wiring ducts or other installed equipment. Its application is distinct from the P0926CM terminal block cable, which connects an input terminal block to a compatible power supply.

In a process control cabinet, the incoming power connection must match the electrical input arrangement of the installed equipment. The P0926TM is identified as an AC input power cable assembly for compatible Foxboro systems. Before replacement, technicians should confirm the existing cable reference, connector configuration and applicable input requirements rather than selecting a cable solely by its length.

The corresponding later part reference is RH926TM. Both references are associated with the 1.2-meter AC input power cable assembly, making the part number an important detail for maintenance records and spare-parts identification.


Technical Specifications

Parameter Specification
Manufacturer Foxboro
Model / Part Number P0926TM
Related Part Number RH926TM
Product Family Standard 200 Series
Product Type AC Input Power Cable Assembly
Primary Function AC input power connection
Application Compatible industrial automation and process control systems
Cable Length 1.2 meters
Shipping Weight 3 kg

Product Features

  • Dedicated AC input connection: Serves the designated power-entry connection in compatible Foxboro installations.
  • 1.2-meter cable length: Accommodates power connections between components positioned apart within a control cabinet.
  • Power-entry application: Belongs to the input power wiring arrangement rather than the downstream baseplate output cable family.
  • Replacement identification: Uses P0926TM as the original part reference, with RH926TM as the related later reference.
  • Cabinet routing: Supports planned cable routing around installed control equipment and wiring ducts.
  • Configuration-specific selection: Requires confirmation of the equipment input interface and connector arrangement.
  • Maintenance support: Provides a defined part reference for replacement planning and inventory management.

Working Principle

The P0926TM provides the electrical connection required by its specified AC input power arrangement. When installed with compatible equipment, it carries the input power through the designated cable path to the corresponding connection interface.

For example, a control cabinet may contain a dedicated power-entry section separated from the equipment mounting area. A pre-assembled input cable allows the connection to follow the planned cabinet route without requiring the power-entry components to be mounted immediately beside one another.

The cable itself does not regulate voltage, convert AC to DC or distribute power to downstream baseplates. Those functions belong to the connected power supply and other system components. The cable’s role is to maintain the intended electrical connection.

When replacing the P0926TM, the mating connectors and equipment input configuration should be checked carefully. A cable with the same length but a different termination or electrical application should not be treated as interchangeable.


Role in a Foxboro Standard 200 Series Power Architecture

The P0926TM belongs to the input power connection portion of a compatible control system. It should be distinguished from the terminal block cable and the power supply output cables, which serve different positions in the overall power distribution arrangement.

Incoming AC Power → Compatible Input Connection → P0926TM Cable Assembly → Designated Equipment Input

System Component Function Relationship to the Cable
Incoming AC Supply Provides electrical input to the installation Supplies the power carried through the designated input path
Input Connection Interface Provides the mating connection for incoming power Connects the cable to the intended equipment
P0926TM Cable Assembly Carries input power through the specified connection Establishes the dedicated cable path
Compatible Power Supply Converts accepted input power into the required output where applicable Receives input power through its designated interface
Power Supply Output Cables Carry power to compatible baseplates Serve a separate downstream connection function
Modular Baseplates Support compatible control modules Receive power through the appropriate output arrangement
Cabinet Wiring Ducts Organize electrical cable routing Provide a planned route through the cabinet

Industrial Applications

Application Typical Equipment Role of the Cable
Process Automation Foxboro control cabinets Supports the designated AC input power connection
Chemical Processing Process monitoring and control equipment Connects compatible power-entry components
Oil and Gas Facilities Industrial process control installations Forms part of the specified equipment input wiring
Power Generation Plant monitoring and control cabinets Supports input power wiring for compatible equipment
Manufacturing Plants Industrial automation cabinets Accommodates power cable routing between installed components
Water and Wastewater Treatment Process control panels Supports the designated power input connection
Control Cabinet Refurbishment Existing Foxboro installations Replaces a matching input power cable during maintenance
Equipment Replacement Compatible power assemblies Provides the required cable connection when the original configuration matches

Installation and Maintenance

  1. Verify the part reference: Confirm that P0926TM or the related RH926TM reference matches the required AC input power cable assembly.
  2. Identify the connected equipment: Check the installed equipment model and its specified input connection before removing the existing cable.
  3. Isolate incoming power: Follow the applicable shutdown and electrical isolation procedures before handling the cable.
  4. Inspect the connectors: Check the mating ends for contamination, deformation, loose contacts or visible damage.
  5. Examine the cable jacket: Look for cuts, abrasion, crushing or other signs of mechanical damage.
  6. Plan the routing path: Position the cable so it reaches the connection points without excessive tension or sharp bends.
  7. Connect the input end: Fit the cable to the designated input interface according to the equipment’s connection requirements.
  8. Secure the mating connection: Ensure that the connector is properly seated and retained according to the specified arrangement.
  9. Separate incompatible wiring routes: Keep power wiring arranged appropriately in relation to signal and communication cables.
  10. Check the electrical configuration: Confirm that the incoming voltage and input type match the connected equipment’s ratings before energizing the system.
  11. Verify operation: Restore power according to the approved procedure and check the connected equipment for normal startup and any input-related alarms.
  12. Record the maintenance: Document the cable reference, connection points, replacement date and any damage found during inspection.

Compatible System Components

Component Function Compatibility Consideration
Foxboro RH926TM AC Input Power Cable Assembly Related later reference for P0926TM; verify the exact connector configuration
Foxboro P0926CM AC Input Terminal Block Cable Connects a compatible input terminal block to the designated power supply
Foxboro RH926CM AC Input Terminal Block Cable Related later reference for P0926CM
Foxboro P0926DZ AC/DC Input Terminal Block Used in the applicable terminal block power-entry arrangement
Foxboro P0922YU FPS400-24 Power Supply Associated with the specified AC/DC input terminal block arrangement
Foxboro P0922YC FPS400-24 Power Supply 24 V DC input variant with a separate input connection arrangement
Foxboro RH923DG DC Input Terminal Block Cable Used for the corresponding DC input configuration; not a direct substitute for an AC input cable
Foxboro RH926K-Series Cables Power Supply Output Cables Connect a compatible power supply to modular baseplates downstream

Recommended Related Models

Model / Product Product Type Relationship Selection Consideration
Foxboro RH926TM AC Input Power Cable Assembly Related later reference for P0926TM Confirm the equipment interface and input requirements
Foxboro P0926CM AC Input Terminal Block Cable Related power-entry cable with a different connection function Select when the required connection is between the terminal block and power supply
Foxboro RH926CM AC Input Terminal Block Cable Later reference for P0926CM Verify the terminal block and supply arrangement
Foxboro P0926KQ I/A Series 200 Power Supply Output Cable Downstream power supply-to-baseplate cable Select only when a baseplate output connection is required
Foxboro RH926KQ I/A Series 200 Power Supply Output Cable Related later output cable reference Verify the baseplate family and required cable length
Foxboro P0923NG I/A Series 200 Power Supply Y-Cable Branching cable for additional physical baseplate connections Used for a different connection function, not as a direct AC input cable

Key Advantages

  • Provides a dedicated cable assembly for compatible AC input power connections.
  • Offers a 1.2-meter cable length for cabinet routing.
  • Distinguishes the input power connection from terminal block and baseplate output cabling.
  • Provides identifiable part references for replacement and maintenance records.
  • Supports organized power wiring in compatible industrial control installations.

Technical FAQs

What is the difference between P0926TM and P0926CM?

P0926TM is identified as an AC input power cable assembly, while P0926CM is an AC input terminal block cable. Their connection functions differ, so the installed equipment and mating interfaces must be checked before selecting a replacement.

What should be verified before installing the P0926TM?

Confirm the complete part reference, the equipment’s input requirements, the connector arrangement and the intended cable route. The replacement must match the required connection rather than merely having the correct cable length.

Can P0926TM replace a power supply output cable such as P0926KQ?

No. P0926TM is an AC input power cable assembly, whereas P0926KQ belongs to the power supply output cable family used for compatible baseplate connections. The two cable types serve different positions in the power distribution system.

What could cause an input power connection to fail after cable replacement?

Possible causes include an incorrectly seated connector, a damaged cable, an incompatible termination or an input configuration that does not match the connected equipment. Verify the electrical isolation procedure, connection arrangement and equipment input requirements before troubleshooting.



Related Products

Get the latest price? We will reply as soon as possible (within 12 hours)

No:77501