• Foxboro P0923NG I/A Series 200 Power Supply Y-Cable
  • Foxboro P0923NG I/A Series 200 Power Supply Y-Cable
  • Foxboro P0923NG I/A Series 200 Power Supply Y-Cable
  • Foxboro P0923NG I/A Series 200 Power Supply Y-Cable
Product Overview The Foxboro P0923NG I/A Series 200 Power Supply Y-Cable is a power distribution accessory for compatible FPS400-style power supplies used in Foxboro Standard 200 Series control systems.……
Foxboro P0923NG I/A Series 200 Power Supply Y-Cable
  • Foxboro
  • P0923NG
  • Power Supply Y-Cable
  • USA
  • 0.5 meters
  • 3 kg
  • Xiamen, China
  • New & In Stock
  • T/T, PayPal, Western Union
  • 1 Year
  • 1-3 Working Days
  • DHL, UPS, TNT, FedEx and EMS.
  • 24-Hour Service
  • COO
  • 5

Our advantage

Foxboro P0923NG I/A Series 200 Power Supply Y-Cable

Global Logistics

We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.

Foxboro P0923NG I/A Series 200 Power Supply Y-Cable

Brand new and original

Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.

Foxboro P0923NG I/A Series 200 Power Supply Y-Cable

24-hour service

We provide 7*24 hours service to our customers. We will be there whenever you need us.

Foxboro P0923NG I/A Series 200 Power Supply Y-Cable

Price advantage

All our products are priced very favorably because we have our own warehouse and supply.


Company Information
E-mail [email protected]
Mobile +8615980777398
Whatsapp +8615980777398
WeChat 15980777398

Product Overview

The Foxboro P0923NG I/A Series 200 Power Supply Y-Cable is a power distribution accessory for compatible FPS400-style power supplies used in Foxboro Standard 200 Series control systems. Unlike a conventional power supply output cable with a single connection path, this Y-cable branches the power connection to provide additional physical connections for multiple baseplates.

The P0923NG has a cable length of 0.5 meters. It addresses a specific cabinet installation constraint: when all six available power connections on an FPS400-style supply are occupied, the Y-cable can extend the connection arrangement using existing Foxboro three-pin power cables. Its pin connection attaches to the power supply, while the socket branches connect to the cables leading to the baseplates.

This arrangement is useful when expanding an existing distributed control system without relocating the installed power supply. For example, a control cabinet may require additional baseplate connections after more fieldbus modules are added. The Y-cable provides another physical connection path, but the expansion must remain within the power supply’s rated capacity and the applicable system configuration.

The P0923NG is the earlier part reference; RH923NG is the corresponding later reference. Both are associated with the same 0.5-meter Y-cable application. During replacement, the connector arrangement and power supply compatibility matter more than cable length alone.


Technical Specifications

Parameter Specification
Manufacturer Foxboro
Model / Part Number P0923NG
Related Part Number RH923NG
Product Family I/A Series 200
Product Type Power Supply Y-Cable
Cable Configuration Y-shaped power distribution cable
Primary Function Provides additional physical power connections
Compatible Power Supply FPS400-style power supply
Associated Power Supply Models P0922YU / P0922YC
Cable Length 0.5 meters
Connector Arrangement Pin connection to supply; socket branches to existing three-pin power cables
Cable Construction Shielded, 16 AWG
Shipping Weight 3 kg

Product Features

  • Y-shaped power distribution: Branches the power connection to support additional baseplate connections.
  • 0.5-meter cable length: Accommodates the short connection between the supply and the branching point.
  • FPS400-style compatibility: Supports the applicable Standard 200 Series power supply arrangement.
  • Pin-and-socket connections: Connects to the power supply on one side and existing three-pin power cables on the branch side.
  • Expansion support: Helps accommodate additional baseplate connections when the supply’s existing physical connections are fully occupied.
  • Shielded cable construction: Uses the specified 16 AWG shielded cable arrangement.
  • Replacement identification: P0923NG and RH923NG identify the earlier and corresponding later part references.

Working Principle

The P0923NG branches the power connection from an FPS400-style power supply into additional physical connection paths. The pin end connects to the supply, while the socket ends connect to compatible three-pin power cables that continue to the baseplates.

In a cabinet with several modular baseplates, the number of available supply connections can become a practical limitation before the power supply itself reaches its electrical capacity. The Y-cable addresses that connection constraint by allowing existing power cables to be connected through a shared branching arrangement.

For example, when an additional baseplate is introduced into an established control cabinet, the installer may be able to use the P0923NG to accommodate the required connection without replacing the entire power distribution arrangement. Whether this is permissible depends on the supply’s output ratings, the connected equipment and the applicable installation instructions.

The cable does not increase the power supply’s rated output. It creates additional physical connections only. The combined load must remain within the specified electrical limits, and the complete arrangement must be checked for compatibility before the system is energized.


Role in a Foxboro I/A Series 200 Control System

The P0923NG sits between an FPS400-style power supply and the existing three-pin power cables that connect to compatible baseplates. Its purpose is to expand the available connection arrangement rather than perform power conversion or control processing.

FPS400-Style Power Supply → P0923NG Y-Cable → Existing Three-Pin Power Cables → Compatible Baseplates

System Component Function Relationship to the Y-Cable
FPS400-24 Power Supply Supplies electrical power to compatible control equipment Provides the power connection that the Y-cable branches
P0923NG Y-Cable Creates additional physical power connection paths Connects the supply to existing baseplate power cables
Three-Pin Power Cables Carry power from the branching point to the baseplates Connect to the Y-cable’s socket branches
Modular Baseplates Support compatible fieldbus modules and associated connections Receive power through the connected cables
Fieldbus Modules (FBMs) Perform configured process input/output functions Operate within the powered control system
Control Cabinet Wiring Routes power and signal connections Provides organized routing for the expanded arrangement
Additional Baseplate, Where Required Accommodates further control hardware Adds a connection only when the system’s electrical limits permit

Industrial Applications

Application Typical Equipment Role of the Y-Cable
Distributed Control Systems Foxboro Standard 200 Series cabinets Adds physical power connections when the supply’s existing connection points are insufficient
Process Automation Modular control and fieldbus assemblies Supports expansion of the baseplate power connection arrangement
Chemical Processing Process monitoring and control cabinets Accommodates additional compatible baseplate connections
Oil and Gas Facilities Distributed control system installations Supports cabinet modifications within the specified power limits
Power Generation Plant control and monitoring systems Helps organize additional baseplate power connections
Manufacturing Plants Modular industrial automation cabinets Allows existing three-pin power cables to be connected through a branching cable
Control System Expansion Cabinets receiving additional fieldbus modules Addresses connection availability without increasing supply output capacity
Maintenance and Retrofit Existing FPS400-style installations Provides a replacement option for a matching Y-cable configuration

Installation and Maintenance

  1. Verify the part reference: Confirm that P0923NG or the corresponding RH923NG reference matches the required Y-cable configuration.
  2. Check power supply compatibility: Identify the installed FPS400-style power supply and verify that the connection arrangement supports the cable.
  3. Isolate the power supply: Follow the system’s shutdown and electrical isolation procedures before installing or removing the cable.
  4. Inspect the connectors: Check the pin and socket contacts for contamination, deformation or mechanical damage.
  5. Check the existing power cables: Confirm that the three-pin cables connected to the branch outputs are compatible and in serviceable condition.
  6. Plan the cable route: Position the Y-cable so that the short connection can be made without excessive tension or sharp bends.
  7. Connect the pin end: Attach the designated pin connection to the power supply interface according to the applicable connection arrangement.
  8. Connect the branch outputs: Attach the compatible existing three-pin power cables to the socket branches.
  9. Secure the cable routing: Keep the cable away from sharp cabinet edges, moving parts and sources of unsuitable heat.
  10. Verify the total electrical load: Check the combined load of the connected baseplates against the power supply’s ratings and applicable system requirements.
  11. Restore power and check operation: Follow the approved startup procedure and verify that the connected baseplates receive power normally.
  12. Record the installation: Document the cable reference, connected baseplates, connection arrangement and any issues identified during commissioning.

Compatible System Components

Component Function Compatibility Consideration
Foxboro FPS400-24 Supplies power to compatible Standard 200 Series equipment Verify the installed supply model and electrical ratings
Foxboro P0922YU FPS400-24 power supply variant for the applicable input arrangement Confirm the supply connection and system configuration
Foxboro P0922YC FPS400-24 power supply variant for the applicable input arrangement Confirm compatibility with the installed power distribution system
Foxboro Three-Pin Power Cables Connect the supply or branching point to baseplates Must match the Y-cable socket connections
Foxboro Modular Baseplates Support compatible fieldbus modules Confirm the applicable baseplate family and power requirements
Foxboro RH923NG Corresponding later Y-cable reference Check the installed connector arrangement before replacement
Foxboro RH926KK Standard baseplate power supply cable, 0.4 meters Used for compatible direct supply-to-baseplate connections
Foxboro RH926KL Standard baseplate power supply cable, 0.9 meters Select when a direct connection of this length is required
Foxboro RH926KP Standard baseplate power supply cable, 1.8 meters Provides a longer direct connection for compatible baseplates
Foxboro RH926KQ Standard baseplate power supply cable, 2.1 meters Provides a longer direct connection; it is not a substitute for the Y-cable’s branching function

Recommended Related Models

Model / Product Product Type Relationship Selection Consideration
Foxboro RH923NG I/A Series 200 Power Supply Y-Cable Corresponding later reference for P0923NG Verify connector compatibility and the installed supply arrangement
Foxboro P0922YU FPS400-24 Power Supply Associated power supply variant Confirm input requirements and the applicable power distribution configuration
Foxboro P0922YC FPS400-24 Power Supply Associated power supply variant Verify the supply model and system requirements
Foxboro RH926KK I/A Series 200 Power Supply Cable Direct supply-to-baseplate cable, 0.4 meters Consider when a direct connection is required instead of a branching connection
Foxboro RH926KP I/A Series 200 Power Supply Cable Direct supply-to-baseplate cable, 1.8 meters Consider when the installation requires a longer direct connection
Foxboro RH926KQ I/A Series 200 Power Supply Cable Direct supply-to-baseplate cable, 2.1 meters Select according to the required direct connection and baseplate configuration

Key Advantages

  • Adds physical power connections to compatible FPS400-style installations.
  • Uses a 0.5-meter Y-cable arrangement for branching existing three-pin power cables.
  • Supports baseplate connection expansion when the supply’s physical connection count is limiting.
  • Provides identifiable part references for replacement and inventory management.
  • Allows existing compatible power cables to remain in the installation.

Technical FAQs

What problem does the P0923NG solve in an FPS400-style installation?

It provides additional physical power connections when the six available connections on the supply are insufficient for the intended baseplate arrangement. It does not increase the power supply’s rated output.

How are the connectors arranged on the P0923NG?

The pin end connects to the power supply, while the socket branches connect to compatible existing three-pin power cables leading to baseplates. The connector arrangement should be checked against the installed equipment before fitting.

Can the P0923NG be used to add more baseplates without checking the power load?

No. The Y-cable expands physical connectivity, not electrical capacity. The combined connected load must remain within the power supply’s specified ratings and the applicable system requirements.

What is the relationship between P0923NG and RH923NG?

P0923NG is the earlier part reference, while RH923NG is the corresponding later reference for the 0.5-meter Y-cable. Replacement selection should still account for the installed connectors and system configuration.



Related Products

Get the latest price? We will reply as soon as possible (within 12 hours)