• Schneider TSXDMZ16DTK Modicon TSX Micro Discrete Solid State I/O Base DC
  • Schneider TSXDMZ16DTK Modicon TSX Micro Discrete Solid State I/O Base DC
  • Schneider TSXDMZ16DTK Modicon TSX Micro Discrete Solid State I/O Base DC
  • Schneider TSXDMZ16DTK Modicon TSX Micro Discrete Solid State I/O Base DC
Product Overview The Schneider TSXDMZ16DTK Modicon TSX Micro Discrete Solid State I/O Base DC combines discrete input acquisition and solid-state output switching in a single I/O module for compatible M……
Schneider TSXDMZ16DTK Modicon TSX Micro Discrete Solid State I/O Base DC
  • Schneider
  • TSXDMZ16DTK
  • Discrete Solid State I/O Base DC
  • France
  • 260 × 180 × 55 mm
  • 0.16 kg
  • Xiamen, China
  • New & In Stock
  • T/T, PayPal, Western Union
  • 1 Year
  • 1-3 Working Days
  • DHL, UPS, TNT, FedEx and EMS.
  • 24-Hour Service
  • COO
  • 6

Our advantage

Schneider TSXDMZ16DTK Modicon TSX Micro Discrete Solid State I/O Base DC

Global Logistics

We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.

Schneider TSXDMZ16DTK Modicon TSX Micro Discrete Solid State I/O Base DC

Brand new and original

Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.

Schneider TSXDMZ16DTK Modicon TSX Micro Discrete Solid State I/O Base DC

24-hour service

We provide 7*24 hours service to our customers. We will be there whenever you need us.

Schneider TSXDMZ16DTK Modicon TSX Micro Discrete Solid State I/O Base DC

Price advantage

All our products are priced very favorably because we have our own warehouse and supply.


Company Information
E-mail [email protected]
Mobile +8615980777398
Whatsapp +8615980777398
WeChat 15980777398

Product Overview

The Schneider TSXDMZ16DTK Modicon TSX Micro Discrete Solid State I/O Base DC combines discrete input acquisition and solid-state output switching in a single I/O module for compatible Modicon TSX Micro automation systems. It provides 8 digital inputs and 8 transistor outputs, allowing a PLC to monitor field sensors while controlling connected DC devices.

The eight 24 V DC positive-logic inputs acquire signals from compatible 2-wire and 3-wire proximity sensors, limit switches and other switching devices. The eight static outputs switch compatible DC loads according to the PLC program, making the module suitable for small machines that require both feedback signals and direct control outputs.

An HE-10 connector supports grouped field wiring, while a separate power connection supplies the module’s output circuit. This arrangement helps organize sensor and actuator connections in a control cabinet. During system design, the input signal characteristics, output current demand and external load protection requirements should be checked against the connected field devices.


Technical Specifications

Parameter Specification
Manufacturer Schneider Electric
Model TSXDMZ16DTK
Product Series Modicon TSX Micro
Product Type Discrete Solid-State I/O Base DC
Total I/O Points 16
Number of Inputs 8
Number of Outputs 8
Input Voltage 24 V DC
Input Logic Positive logic, Type 1
Nominal Input Current 7 mA
Sensor Supply Voltage Range 19–30 V DC
Guaranteed Logic State 1 Voltage ≥ 11 V
Guaranteed Logic State 1 Current > 2.5 mA at 11 V
Guaranteed Logic State 0 Voltage < 5 V
Guaranteed Logic State 0 Current < 1.5 mA
Input Impedance 3.4 kΩ
Input Response Time Configurable from 0.1 to 7.5 ms
Output Type Static solid-state DC outputs
Output Rating 24 V DC, 0.5 A per output
Sensor Compatibility Compatible 2-wire and 3-wire proximity sensors
Field Connection HE-10 connector and separate power terminal block
Input Standard IEC 1131-2 Type 1
Dimensions 260 × 180 × 55 mm
Weight 0.16 kg

Product Features

  • Combined input and output functionality: Provides eight inputs and eight outputs in one I/O module.
  • 24 V DC input signals: Acquires compatible positive-logic signals from industrial sensors and switching devices.
  • Static DC outputs: Uses solid-state switching to control compatible DC loads.
  • 0.5 A output rating: Supports loads within the specified current limit for each output.
  • Configurable input response: Offers input response settings from 0.1 to 7.5 ms.
  • Sensor compatibility: Supports compatible 2-wire and 3-wire proximity sensor arrangements.
  • HE-10 field connection: Simplifies grouped wiring between the module and field devices.
  • Separate output power connection: Allows the output supply to be connected according to the module’s wiring requirements.
  • TSX Micro integration: Supports combined signal acquisition and actuator control within compatible PLC installations.
  • Machine-level I/O consolidation: Reduces the need to use separate input-only and output-only modules for small groups of DC signals.

Working Principle

The TSXDMZ16DTK receives field signals through its eight discrete input channels. Each input evaluates the incoming 24 V DC signal against the module’s logic thresholds. When the signal reaches a valid ON or OFF state, the corresponding input information becomes available to the TSX Micro PLC program.

The input response time can be configured from 0.1 to 7.5 ms for transitions in either direction. This setting affects how quickly input changes are recognized, so it should match the sensor characteristics and the machine’s sequence requirements. Signals that fail to meet the guaranteed voltage or current thresholds may be interpreted incorrectly.

The module’s eight solid-state outputs switch compatible 24 V DC loads in response to PLC commands. Each output is rated at 0.5 A, so the load current and switching conditions must remain within the specified limits. Inductive loads may require suitable suppression components, and the output supply must be wired according to the module’s connection instructions.

During commissioning, technicians should test the input and output channels separately. First confirm that field sensors produce the expected PLC input states, then command each output and verify that the connected actuator or load responds correctly. If an output does not operate, check the output supply, wiring, load current and PLC command state before replacing the module.


Role in a Modicon TSX Micro Control Architecture

The TSXDMZ16DTK provides a combined field-interface layer between a Modicon TSX Micro PLC and connected sensors and DC actuators. The input channels deliver machine-state information to the controller, while the output channels execute commands generated by the PLC application.

System Component Function Relationship to the TSXDMZ16DTK
Modicon TSX Micro PLC Executes machine logic and sequencing Reads the eight input states and controls the eight outputs
24 V DC Power Supply Supplies field devices and output circuits Must meet the requirements of the sensors and connected loads
Proximity Sensor Detects target presence or movement Supplies a compatible signal to an input channel
Limit Switch Detects a mechanical position or end condition Provides discrete status feedback
Photoelectric Sensor Detects products or material Supplies object-detection signals to the input channels
DC Solenoid Valve Operates a pneumatic or hydraulic function Can be controlled through a compatible output circuit within the rating
Indicator Lamp Displays machine or process status Can be driven by a compatible output load
Small DC Relay Switches an external circuit May be used when the external load requires an interface stage
HE-10 Cable Carries grouped I/O signals Connects the module to compatible field wiring or interface equipment
Output Power Supply Supplies the static output circuit Must be wired according to the module’s power-connection requirements

Industrial Applications

Application Operating Requirement Role of the TSXDMZ16DTK
Small Assembly Machines Read part-presence sensors and operate actuators Combines sensor acquisition and DC output control
Conveyor Transfer Stations Detect product position and control stop devices Reads sensor signals and switches compatible DC loads
Packaging Equipment Monitor cycle conditions and actuate small mechanisms Provides input feedback and output commands for sequence control
Pneumatic Handling Systems Detect cylinder positions and operate solenoid valves Acquires end-position signals and controls compatible valve loads
Component Feeding Machines Detect component availability and actuate feeders Coordinates input feedback with output switching
Inspection Fixtures Read fixture and part-status sensors Transfers discrete conditions to the PLC and operates indicators or actuators
Machine Status Panels Monitor switches and operate status indicators Combines discrete monitoring with local DC output control
Compact Legacy Automation Systems Maintain combined I/O in a TSX Micro installation Supports applications needing a modest number of DC input and output points

Installation and Maintenance

  1. Verify the module reference: Confirm that the installed module is TSXDMZ16DTK and that the TSX Micro PLC configuration supports the intended I/O arrangement.
  2. Check the input supply: Verify that the sensor circuits provide compatible 24 V DC positive-logic signals within the specified voltage range.
  3. Inspect the HE-10 connector: Confirm correct alignment, secure mating and sound contact condition before energizing the system.
  4. Verify the output supply connection: Check the separate power terminal block and confirm that the output circuit is supplied according to the wiring instructions.
  5. Check output load current: Ensure each connected load stays within the specified 0.5 A output rating and that the overall load arrangement meets the module’s limits.
  6. Confirm sensor compatibility: Verify the output type, leakage current and signal voltage of each connected sensor against the module’s input thresholds.
  7. Review field wiring: Match sensor and actuator conductors to the correct channel assignments and PLC addresses.
  8. Test input channels: Operate each sensor or switch and confirm that the corresponding input state appears correctly in the PLC application.
  9. Test output channels: Command each output separately and verify the connected load operates as expected without exceeding its current rating.
  10. Check inductive loads: Review suppression requirements for solenoids, relays and other inductive devices to limit switching transients.
  11. Investigate unexpected channel behavior: Check field power, connector contacts, load wiring and PLC logic before concluding that the module has failed.
  12. Record commissioning results: Document the input assignments, output loads, supply arrangements, parameter settings and channel test results.

Compatible System Components

Component Function Compatibility Consideration
Modicon TSX Micro PLC Executes the automation program Verify CPU and system configuration compatibility
24 V DC Power Supply Supplies compatible sensors and output circuits Confirm voltage stability and current capacity
2-Wire Proximity Sensor Detects target presence Verify leakage current and input-threshold compatibility
3-Wire Proximity Sensor Provides a discrete detection signal Confirm positive-logic output compatibility
Photoelectric Sensor Detects products or material movement Check output type, voltage and current characteristics
DC Solenoid Valve Operates a pneumatic or hydraulic actuator Confirm coil current and suitable suppression
Indicator Lamp Provides visual machine status Verify voltage and current requirements
Interface Relay Switches a separate load circuit Select a relay with a compatible coil and suitable contact rating
HE-10 Pre-wired Cable Connects grouped field signals Verify pinout, connector type and cable arrangement

Recommended Related Models

Model Product Type Relationship Selection Consideration
Schneider TSXDMZ16DTK Modicon TSX Micro Discrete Solid-State I/O Base DC Same model reference Use when replacing an existing unit and matching its electrical configuration
Schneider TSXDEZ12D2 Modicon TSX Micro Discrete Input Module Related input-only module Consider when the application needs discrete inputs but does not require integrated outputs
Schneider TSXDEY16FK Modicon Premium Discrete Input Module Related discrete input module from another Schneider PLC family Verify platform and rack compatibility; it is not a direct substitute
Schneider TSXDSZ08R5 Modicon TSX Micro Discrete Output Module Related output-only module Evaluate when the application needs a separate output module and its output type matches the load
Schneider TSX Micro PLC Programmable Logic Controller Host automation platform Confirm that the CPU and configuration support the module

Key Advantages

  • Combines eight 24 V DC inputs and eight static DC outputs in one module.
  • Supports compatible 2-wire and 3-wire proximity sensors.
  • Provides configurable input response times from 0.1 to 7.5 ms.
  • Uses solid-state outputs rated at 24 V DC and 0.5 A per output.
  • Supports grouped field wiring through an HE-10 connector.
  • Integrates sensor feedback and DC load control in compatible TSX Micro systems.

Technical FAQs

What should be checked when the TSXDMZ16DTK detects an input signal intermittently?

Measure the sensor signal at the module terminal and compare it with the specified ON-state and OFF-state thresholds. Check the selected input response time, sensor leakage current, field supply stability and connector contacts before changing the PLC logic.

Can the module directly operate a 24 V DC solenoid valve?

It can operate a compatible DC load only when the load’s steady-state and switching requirements remain within the output ratings. Verify coil current, inductive switching behavior and suppression requirements before connecting the valve directly.

Why might an input operate correctly while its associated output does not switch?

Input acquisition and output switching are separate functions. Check the PLC program condition, output command state, output supply connection, field wiring and connected load current to determine where the command path is interrupted.

What information is needed when replacing the TSXDMZ16DTK in an existing TSX Micro machine?

Confirm the exact I/O arrangement, input logic, output voltage and current requirements, connector pinout, output supply wiring and PLC channel assignments. Test every input and output after replacement to verify that the original machine sequence behaves as expected.



Related Products

Get the latest price? We will reply as soon as possible (within 12 hours)

No:77501