Our advantage
Global Logistics
We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.
Brand new and original
Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.
24-hour service
We provide 7*24 hours service to our customers. We will be there whenever you need us.
Price advantage
All our products are priced very favorably because we have our own warehouse and supply.
| Company Information | |||
| [email protected] | |||
| Mobile | +8615980777398 | ||
| +8615980777398 | |||
| 15980777398 |

The Epro PR6424/004-021 16 mm Eddy Current Sensor is an industrial sensing component designed for non-contact measurement applications involving conductive metal targets. Eddy current technology is widely used in machinery monitoring because it allows displacement and relative movement to be measured without direct physical contact between the sensor and the target.
In industrial environments, accurate shaft position and vibration measurements can help maintenance personnel identify changes in rotating machinery behavior. Eddy current sensors are commonly incorporated into monitoring arrangements for turbines, compressors, pumps, motors, and other critical equipment.
The Epro PR6424/004-021 has a specified sensor head diameter of 16 mm and a listed weight of 0.2 kg. These physical characteristics are useful when assessing installation space, replacement requirements, mounting arrangements, and spare-parts inventory.
For maintenance engineers and industrial automation system integrators, selecting the correct probe configuration is essential. Before installation, the model number, measurement range, electrical interface, cable arrangement, and compatibility with the associated signal conditioning equipment should be verified against the applicable technical documentation.
| Parameter | Specification |
|---|---|
| Brand | Epro |
| Model Number | PR6424/004-021 |
| Product Type | Eddy Current Sensor |
| Sensor Head Diameter | 16 mm |
| Weight | 0.2 kg |
| Sensing Technology | Eddy current, non-contact measurement |
| Target Material | Conductive metal |
| Typical Application | Machinery displacement and vibration monitoring |
| Mounting Arrangement | According to the applicable sensor configuration |
| Signal Processing | Requires a compatible measurement interface |
| Measuring Range | Verify against the exact model documentation |
| Sensitivity | Verify against the exact model documentation |
| Cable Configuration | Confirm before installation |
| Operating Temperature | Confirm the approved operating limits |
| System Compatibility | Verify the complete probe and monitoring arrangement |
The table includes the supplied product information and general characteristics of eddy current sensing. Detailed electrical and performance parameters should not be assumed from the sensor head diameter or product family alone.
An eddy current sensor operates by generating an alternating electromagnetic field around its sensing element. When a conductive metal target is positioned within this field, eddy currents are induced in the target surface. These currents influence the electromagnetic field and change the electrical response of the sensing system.
The associated electronics evaluate these changes and convert them into a measurement signal related to the distance between the sensor and the target.
Because the sensor does not need to touch the measured surface, this technology is suitable for many applications involving rotating shafts and other moving metal components. Correct operation depends on the sensor being installed within its specified measuring range and connected to compatible signal conditioning equipment.
In machinery applications, the sensor may be positioned near a shaft or another conductive component to detect changes in the gap between the target and the probe.
These measurements can help engineers evaluate relative movement and position changes. Depending on the complete installation, displacement information may be used to monitor axial movement, radial movement, or other machine-specific parameters.
The sensor must be mounted securely and aligned with the intended measurement direction. Incorrect positioning, unsuitable target materials, or an out-of-range gap can result in inaccurate or unstable readings.
Eddy current sensing is commonly used to measure relative shaft vibration in compatible machinery monitoring systems. As a shaft moves during operation, the distance between the shaft surface and the probe changes. The resulting signal can be processed to evaluate vibration behavior.
The quality of the final measurement depends on the entire measurement chain, including the probe, any required extension cable, signal conditioner, monitoring module, and configured processing parameters.
The PR6424/004-021 should therefore be evaluated as a component of a complete monitoring system rather than as a standalone vibration protection device.
When installed in a suitable system, an eddy current sensor can provide continuous measurement data during machinery operation. Monitoring equipment can compare these readings with established operating baselines and configured alarm thresholds.
This information supports condition-based maintenance, helping plant personnel investigate unusual machine behavior before it develops into a more serious operational issue.
Rotating equipment can experience changes in shaft position and vibration because of operating conditions, mechanical wear, alignment issues, or other factors. A correctly selected eddy current sensor can supply non-contact measurements for evaluating these changes.
Applications may include turbines, compressors, industrial motors, and other machines where shaft displacement measurements are required.
Trend data can help maintenance personnel identify changes from normal operating conditions. However, an abnormal measurement does not independently identify the underlying fault. It should be assessed alongside operating speed, load, temperature, maintenance history, and other available machine data.
The sensor may form part of a larger system containing signal conditioning equipment, monitoring modules, protection devices, data acquisition hardware, and industrial control interfaces.
The exact integration method depends on the sensor’s electrical characteristics and the system architecture. Verify compatibility before connecting the probe to a monitoring module or control system.
Continuous measurement data can help maintenance teams establish operating baselines, track developing trends, and schedule inspections according to actual equipment condition.
This approach can reduce unnecessary maintenance while helping identify equipment that requires further investigation.
Steam and gas turbines require appropriate monitoring of shaft behavior and mechanical operating conditions. Eddy current sensors are used in suitable turbine monitoring arrangements to measure relative shaft movement without direct contact.
The PR6424/004-021 may be considered for an application when its verified performance and system compatibility satisfy the turbine’s monitoring requirements.
Industrial compressors in chemical processing, petrochemical facilities, and other process industries often operate continuously under demanding conditions. Non-contact shaft measurements can support the assessment of vibration and displacement trends.
Selection should account for the compressor design, shaft material, mounting position, required measurement range, and associated monitoring electronics.
Pumps used in process plants and utility systems can benefit from machinery condition monitoring. Where shaft displacement measurements are required, a suitable eddy current sensor may provide useful data for troubleshooting and maintenance planning.
Large industrial motors and associated rotating equipment may use non-contact sensing as part of a wider vibration monitoring strategy. Measurement data can be evaluated alongside electrical, thermal, and mechanical operating parameters.
Power generation facilities and continuous-process plants often rely on integrated machinery monitoring systems. Correctly selected sensors provide measurement inputs that help operators and maintenance personnel assess equipment behavior and investigate abnormal trends.
Proper installation is essential for measurement accuracy and long-term reliability. The following steps provide a general checklist. The approved instructions for the exact PR6424/004-021 configuration take precedence.
Confirm the full model number on the product label and compare it with the equipment documentation. Check the sensor head, connector, cable arrangement, and any supplied mounting components.
Do not assume that all sensors in the same series have identical measuring ranges, sensitivities, or connection requirements.
Inspect the probe for visible damage, contamination, corrosion, or deformation. Examine the cable and connector for cuts, crushing, loose contacts, or other signs of damage.
If the sensor has been exposed to impact, excessive heat, or severe operating conditions, verify its condition before installation.
Choose a mounting location that provides sufficient mechanical stability and the required clearance from the moving target.
The 16 mm sensor head diameter is a useful dimensional reference, but the mounting bore, thread, bracket arrangement, and total installation clearance must be confirmed from the actual sensor design.
Position the sensor relative to the conductive target using the specified installation procedure. Set the initial gap within the approved measurement range and ensure that expected shaft movement will not cause contact between the probe and target.
Avoid estimating the gap by sight alone. An incorrect gap can produce an out-of-range signal or reduce measurement accuracy.
Protect the cable from abrasion, crushing, excessive bending, high temperatures, and moving machinery. Follow the system’s requirements for cable routing and separation from electrical noise sources.
If the installation uses an extension cable, confirm that its type and length are appropriate for the probe and associated electronics.
Check the electrical interface, connector arrangement, and signal conditioning requirements before connecting the sensor. Confirm that the connected electronics are designed for the exact probe configuration.
Do not assume that the probe can connect directly to a standard PLC analog input. A compatible signal conditioning or monitoring device may be required.
After installation, inspect all connections and verify the sensor’s mechanical position. Check that the monitoring equipment displays a plausible measurement and that the signal responds as expected under the approved test procedure.
Investigate unstable, saturated, or out-of-range readings before returning the monitored equipment to normal service.
Document the sensor model, installation position, probe gap, cable arrangement, associated monitoring equipment, and commissioning results. Record relevant baseline measurements under known operating conditions.
These records provide a reference for future maintenance and help technicians distinguish normal variations from changes requiring investigation.
Possible causes:
Recommended troubleshooting:
Inspect the complete signal path from the probe to the monitoring equipment. Verify all connections and confirm that the associated electronics support the exact sensor configuration. Test the cable and probe using the approved procedure before deciding which component requires replacement.
Possible causes:
Recommended troubleshooting:
Check the mounting hardware and cable condition. Verify the probe position and review the signal conditioning setup. Compare the measurement with the machine’s operating state to determine whether the fluctuation represents actual shaft movement or an issue within the measurement chain.
Possible causes:
Recommended troubleshooting:
Confirm the probe position and compare the connected equipment settings with the approved documentation. Verify the specified measurement range and scaling parameters. Do not change alarm thresholds simply to suppress an abnormal value without identifying its cause.
Possible causes:
Recommended troubleshooting:
Verify the replacement part number and the complete system configuration. Check the mounting arrangement, cable type, and measurement settings. Repeat the approved commissioning procedure and document the verified results.
A non-contact sensor can still be damaged by incorrect installation, accidental impact, contamination, excessive heat, or contact with a moving machine component.
Inspect the probe and mounting arrangement. If the sensor’s condition or measurement performance cannot be verified, test or replace it according to the site’s maintenance procedure.
Safety note: Follow the plant’s isolation and lockout procedures before inspecting or replacing sensors near operating machinery. Changes to a sensor used by a protection system must be managed in accordance with the site’s approved maintenance and safety requirements.
The PR6424/004-021 should be assessed as part of the complete measurement chain. The component categories below describe typical system functions and do not confirm compatibility with any specific part number.
| Component Category | Function | Verification Requirement |
|---|---|---|
| Signal Conditioner | Processes the probe response into a usable measurement signal | Must support the exact probe configuration |
| Extension Cable | Connects the probe to associated electronics when required | Cable type and length must meet system requirements |
| Monitoring Module | Processes displacement or vibration measurements | Must support the specified input characteristics |
| Machinery Protection System | Evaluates measurements against alarm and trip limits | Must be designed for the complete measurement chain |
| Data Acquisition Equipment | Records measurements for analysis and trending | Input range and signal interface must be appropriate |
| Probe Mounting Hardware | Secures the sensor near the target | Must match the sensor and machine mounting design |
| Industrial Control Interface | Transfers monitoring information to other systems where supported | Requires a compatible interface or monitoring-system connection |
Before purchasing additional components, verify the probe type, cable configuration, signal conditioning requirements, and system architecture. Components should not be considered interchangeable solely because they share the same manufacturer.
When the original sensor is unavailable, replacement selection should be based on documented technical compatibility rather than physical similarity alone.
| Replacement Option | Suitable Situation | Important Checks |
|---|---|---|
| Epro PR6424/004-021 | Preferred when the existing configuration requires this exact model | Full part number, physical condition, and system compatibility |
| Another Epro 16 mm Eddy Current Sensor | When an alternative model is being evaluated | Measuring range, sensitivity, electrical interface, and cable configuration |
| Compatible Eddy Current Probe Assembly | When the existing installation requires an approved alternative assembly | Probe, cable, signal conditioner, and mounting compatibility |
| Alternative Monitoring Sensor System | When redesigning or upgrading the monitoring arrangement | Measurement requirements, system interfaces, calibration, and commissioning |
A sensor with the same 16 mm head diameter is not necessarily a direct replacement. Confirm the required electrical characteristics, performance parameters, mechanical installation, and compatibility with the existing monitoring equipment before ordering.
The sensing method measures a conductive target without requiring direct contact. This is useful for applications where the target moves continuously or rotates at high speed.
When integrated into a compatible monitoring system, the sensor can provide ongoing data for condition assessment and trend analysis.
Eddy current technology is widely used in suitable shaft displacement and vibration monitoring applications, helping maintenance teams assess changes in machinery behavior.
The probe can serve as a sensing element in a complete measurement chain that includes signal conditioning, monitoring, data acquisition, and alarm management.
The specified 16 mm sensor head diameter and 0.2 kg weight provide useful reference information for product identification, storage, and installation planning.
It is an Epro 16 mm eddy current sensor intended for non-contact measurement applications involving conductive targets. Its suitability for a particular installation depends on the verified product specifications and monitoring system requirements.
The specified sensor head diameter is 16 mm.
The listed weight is 0.2 kg.
Eddy current sensors are commonly used for non-contact shaft vibration monitoring. Confirm the measurement range, sensitivity, frequency response, and monitoring equipment compatibility for this exact model before using it in a particular application.
Do not assume direct compatibility with a standard PLC input. The required connection depends on the probe’s electrical characteristics and the input design. Suitable signal conditioning or monitoring equipment may be necessary.
Verify the complete model number, mounting dimensions, measurement gap, cable configuration, electrical interface, and compatibility with the associated monitoring equipment.
Possible causes include loose mounting, incorrect probe gap, electrical interference, cable damage, an incompatible interface, or unsuitable target conditions. Check the complete measurement chain rather than replacing the probe immediately.
Not automatically. Matching the head diameter alone does not establish interchangeability. The measurement range, sensitivity, electrical characteristics, cable arrangement, and signal conditioning requirements must also be compatible.
Inspect the sensor and cable periodically, maintain secure mounting, follow the approved installation requirements, and monitor changes in signal behavior. Record maintenance activities and baseline measurements to support future troubleshooting.
Confirm the full part number, required quantity, physical condition, cable and connector configuration, application requirements, and compatibility with the existing monitoring system.
The Epro PR6424/004-021 16 mm Eddy Current Sensor is a non-contact sensing component for suitable industrial displacement and machinery monitoring applications. Its specified sensor head diameter of 16 mm and listed weight of 0.2 kg provide useful physical identification information for maintenance, installation planning, and spare-parts purchasing.
Reliable operation depends on correct mounting, an appropriate measurement gap, compatible signal conditioning, proper cable installation, and systematic commissioning. Before installing or replacing the sensor, verify the exact model configuration and its compatibility with the complete monitoring system.
For industrial maintenance teams, system integrators, and spare-parts purchasers, careful verification helps reduce replacement errors, improve measurement reliability, and support effective machinery condition monitoring.