• GE SR489-P5-HI-A20 Generator Management Relay
  • GE SR489-P5-HI-A20 Generator Management Relay
  • GE SR489-P5-HI-A20 Generator Management Relay
  • GE SR489-P5-HI-A20 Generator Management Relay
Product Overview The GE SR489-P5-HI-A20 Generator Management Relay is part of the GE Multilin 489 generator protection and management family. It combines generator electrical protection, metering, tempe……
GE SR489-P5-HI-A20 Generator Management Relay
  • GE
  • SR489-P5-HI-A20
  • Generator Management Relay
  • USA
  • 252 × 216 × 224 mm
  • 7.7 kg
  • Xiamen, China
  • New & In Stock
  • T/T, PayPal, Western Union
  • 1 Year
  • 1-3 Working Days
  • DHL, UPS, TNT, FedEx and EMS.
  • 24-Hour Service
  • COO
  • 7

Our advantage

GE SR489-P5-HI-A20 Generator Management Relay

Global Logistics

We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.

GE SR489-P5-HI-A20 Generator Management Relay

Brand new and original

Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.

GE SR489-P5-HI-A20 Generator Management Relay

24-hour service

We provide 7*24 hours service to our customers. We will be there whenever you need us.

GE SR489-P5-HI-A20 Generator Management Relay

Price advantage

All our products are priced very favorably because we have our own warehouse and supply.


Company Information
E-mail [email protected]
Mobile +8615980777398
Whatsapp +8615980777398
WeChat 15980777398

Product Overview

The GE SR489-P5-HI-A20 Generator Management Relay is part of the GE Multilin 489 generator protection and management family. It combines generator electrical protection, metering, temperature monitoring, alarm handling and trip control in a dedicated relay package for synchronous and induction generator applications.

This configuration uses 5 A phase current transformer inputs, a high-range control power supply and 4–20 mA analog outputs. The HI power option accepts 90–300 V DC or 70–265 V AC at 48–62 Hz. Unlike versions with the E suffix, this model has the basic display configuration.

The relay evaluates current, voltage and connected condition-monitoring signals against configured protection settings. When an enabled protection element detects a condition that meets its programmed criteria, the relay can activate assigned trip or alarm outputs. Its serial communication interfaces and analog outputs support integration with compatible generator control panels and plant monitoring systems.


Technical Specifications

Parameter Specification
Manufacturer GE
Model / Order Number SR489-P5-HI-A20
Product Family GE Multilin 489
Product Type Generator Management Relay
Phase CT Input Rating 5 A
Control Power Option HI
DC Control Power Input 90–300 V DC
AC Control Power Input 70–265 V AC
AC Control Power Frequency 48–62 Hz
Analog Output Option A20
Analog Output Range 4–20 mA
Display Option Basic display
Analog Output Channels 4 configurable channels
Digital Inputs 9 opto-isolated inputs
RTD Monitoring Supports up to 12 RTD inputs
Communication Interfaces RS232 and RS485
Communication Protocols Modbus RTU, DNP 3.0
Output Relays 6 electromechanical Form-C relays
Protection Functions Configurable generator electrical and thermal protection
Enclosure / Mounting Format Drawout relay package
Dimensions 252 × 216 × 224 mm
Weight 7.7 kg

Product Features

  • Generator protection: Supports configurable protection functions for abnormal electrical and operating conditions.
  • 5 A phase CT inputs: Matches generator protection systems using current transformers with 5 A secondary outputs.
  • High-range control power: Accepts the specified high-range AC or DC auxiliary supply.
  • 4–20 mA analog outputs: Provides four configurable channels for transmitting selected measurements to compatible equipment.
  • Basic local display: Provides local access to relay messages, status and operating information without the enhanced-display option.
  • RTD temperature monitoring: Supports connected temperature sensors for configured generator and bearing monitoring points.
  • Electrical metering: Supplies generator measurements for operating assessment and supervisory monitoring.
  • Trip and alarm outputs: Allows configured protection elements to activate assigned relay contacts.
  • Serial communications: Supports data exchange with compatible supervisory systems and engineering tools.
  • Drawout construction: Allows the relay unit to be withdrawn from its case for inspection and testing under the prescribed isolation procedure.

Working Principle

The SR489-P5-HI-A20 receives generator current and voltage signals from connected instrument transformers. It processes these measurements and compares them with programmed settings for enabled protection elements, which may include overcurrent, voltage, frequency, reverse power and other generator protection functions.

RTD sensors and configured digital inputs provide additional operating information. When a measured condition meets a protection element’s pickup threshold and timing requirements, the relay can operate assigned trip or alarm outputs. Event and diagnostic information can then assist maintenance personnel in investigating abnormal operation.

The A20 option provides four 4–20 mA analog output channels. Each channel can be configured to represent a supported measured parameter, allowing selected generator measurements to be transmitted to compatible meters, controllers or plant monitoring equipment.

The HI option defines the required auxiliary supply range. Correct current-transformer and voltage-transformer wiring, transformer-ratio settings, protection thresholds and output assignments are essential to proper operation. The relay’s response depends on the functions enabled and the settings applied during commissioning.


Role in a Generator Protection and Control Architecture

The GE Multilin 489 serves as a dedicated generator protection and monitoring device between the generator measurement circuits, breaker-control circuitry and plant supervision system. It evaluates connected signals locally and issues configured trip or alarm commands when programmed conditions are satisfied.

System Component Function Relationship to the Relay
Generator Current Transformers Provide scaled generator current signals Supply phase-current measurements matching the 5 A input configuration
Voltage Transformers Provide generator voltage signals Supply voltage measurements for configured protection and metering
RTD Temperature Sensors Measure generator and bearing temperatures Supply thermal information to configured monitoring functions
Generator Circuit Breaker Connects or isolates the generator Receives trip commands through the assigned control circuit
Alarm and Annunciation System Alerts operators to abnormal conditions Receives configured relay alarms and status information
Plant PLC or SCADA System Supervises equipment and displays operating values Exchanges supported measurements and status information
Engineering Computer Configures relay settings and retrieves diagnostics Connects through supported communication interfaces and compatible software
Auxiliary Control Power Supply Powers the relay Must meet the HI option’s specified AC or DC input range

Industrial Applications

Application Protection or Monitoring Task Role of the Relay
Industrial Generator Sets Monitoring generator electrical conditions Evaluates configured protection elements and operates assigned trip or alarm outputs
Standby Power Systems Supervising generator operation during backup service Provides generator protection and operating measurements
Combined Heat and Power Plants Monitoring generators operating alongside plant loads Consolidates protection, metering and diagnostic information
Industrial Power Stations Detecting electrical and thermal operating abnormalities Supports configured generator protection and alarm handling
Cogeneration Systems Monitoring generator output and connected temperature signals Provides electrical measurements and condition monitoring
Generator Control Panels Integrating protection with breaker and operator interfaces Connects instrument-transformer inputs, control outputs and supervisory communications

Installation and Maintenance

  1. Verify the complete order code: Confirm that SR489-P5-HI-A20 matches the required current-input, control-power, analog-output and display configuration.
  2. Check panel mounting requirements: Verify that the panel opening, case arrangement and installation clearances match the applicable installation documentation.
  3. Confirm auxiliary power: Ensure that the supply is within the HI option’s range of 90–300 V DC or 70–265 V AC at 48–62 Hz.
  4. Inspect current transformer wiring: Confirm the 5 A secondary rating, phase identification, polarity and grounding arrangements before connecting current inputs.
  5. Verify voltage transformer connections: Check voltage wiring, phase relationships, transformer ratios and corresponding relay settings.
  6. Check digital input circuits: Verify that external contacts and status signals are connected to the intended opto-isolated inputs.
  7. Test analog output loops: Confirm that receiving equipment supports 4–20 mA signals and that output scaling and loop wiring are correct.
  8. Inspect RTD connections: Verify sensor types, terminal assignments and wiring for configured stator or bearing temperature monitoring.
  9. Review protection settings: Check generator ratings, CT and VT ratios, trip thresholds, time delays and output-relay assignments before commissioning.
  10. Verify communication configuration: Check RS232 or RS485 wiring, protocol selection, baud rate and device addressing where applicable.
  11. Perform functional testing: Test measurement scaling, alarms, trip logic, output contacts and breaker-interface circuits using an approved commissioning procedure.
  12. Document the final configuration: Record the relay order code, control-power range, protection settings, communication parameters and functional test results.

Compatible System Components

Component Function Compatibility Consideration
Phase Current Transformers Supply generator phase-current signals Match the relay’s 5 A secondary input and configured CT ratios
Ground Current Transformer Supplies ground-fault current information Select an arrangement supported by the enabled ground-protection function
Voltage Transformers Supply generator voltage signals Verify secondary ratings, connection type and programmed ratio
RTD Temperature Sensors Monitor stator, bearing or other configured temperatures Confirm sensor type and wiring compatibility
Generator Circuit Breaker Trip Circuit Opens the breaker when a configured trip operates Verify trip-coil ratings and the complete control-circuit design
4–20 mA Analog Input Receives the relay’s analog signals Confirm input range and parameter scaling at the receiving device
RS485 Communication Network Carries serial data between devices Configure compatible communication settings and protocol
Plant PLC or SCADA System Supervises generator status and measurements Map required values using supported communication functions

Recommended Related Models

Model Product Type Relationship Selection Consideration
GE Multilin SR489-P1-HI-A20 Generator Management Relay Related configuration with 1 A phase CT inputs and high-range control power Select only when the connected phase CT secondary rating requires the P1 option
GE Multilin SR489-P5-LO-A20 Generator Management Relay Related configuration with 5 A phase CT inputs and low-range control power Compare the required auxiliary supply range
GE Multilin SR489-P5-HI-A1 Generator Management Relay Related configuration with 5 A phase CT inputs and 0–1 mA analog outputs Consider when the receiving equipment requires the A1 output range
GE Multilin SR489-P5-HI-A20-E Generator Management Relay Related configuration with the same current-input, control-power and analog-output options, but enhanced display Consider when the larger LCD and improved keypad are required

Key Advantages

  • Combines generator protection, metering and monitoring functions in one relay.
  • Supports 5 A phase current transformer inputs.
  • Accepts high-range AC or DC auxiliary power.
  • Provides four configurable 4–20 mA analog output channels.
  • Supports RTD-based temperature monitoring and programmable protection logic.
  • Offers serial communications, local status information and event data for maintenance and supervision.

Technical FAQs

How can the basic display help operators identify an active generator protection condition?

The relay’s front-panel display presents operating messages, and active trips or alarms can override the default status messages. Operators can use these indications together with the relay’s event and trip records to investigate the reported condition.

How should the four A20 analog outputs be assigned in a generator monitoring system?

Each 4–20 mA output channel can be configured to represent a supported measured parameter. Assign channels according to the monitoring system’s requirements, then verify signal scaling, polarity, common return wiring and the receiving input range during commissioning.

What should be verified when replacing this relay in a panel using high-range auxiliary power?

Confirm that the replacement supports the HI supply range of 90–300 V DC or 70–265 V AC at 48–62 Hz. Also compare the 5 A phase CT input, A20 analog-output option, terminal wiring and programmed protection settings before returning the generator to service.

How can the relay’s event records help diagnose repeated generator trips?

Review the recorded event sequence and pre-trip measurements to identify which protection element operated and what the measured conditions were around the trip. Compare those records with the configured pickup thresholds, time delays and instrument-transformer scaling before changing settings.



Related Products

Get the latest price? We will reply as soon as possible (within 12 hours)

No:77501