• Ingersoll Rand 47550997001 47545136001 Temperature Control Valve Maintenance Kit
  • Ingersoll Rand 47550997001 47545136001 Temperature Control Valve Maintenance Kit
  • Ingersoll Rand 47550997001 47545136001 Temperature Control Valve Maintenance Kit
  • Ingersoll Rand 47550997001 47545136001 Temperature Control Valve Maintenance Kit
Product Overview The Ingersoll Rand 47550997001 47545136001 Temperature Control Valve Maintenance Kit is a service kit for maintaining the temperature control valve in compatible Ingersoll Rand compress……
Ingersoll Rand 47550997001 47545136001 Temperature Control Valve Maintenance Kit
  • Ingersoll Rand
  • 47550997001 47545136001
  • Temperature Control Valve Maintenance Kit
  • USA
  • 180 × 140 × 80 mm
  • 1.20 kg
  • Xiamen, China
  • New & In Stock
  • T/T, PayPal, Western Union
  • 1 Year
  • 1-3 Working Days
  • DHL, UPS, TNT, FedEx and EMS.
  • 24-Hour Service
  • COO
  • 37

Our advantage

Ingersoll Rand 47550997001 47545136001 Temperature Control Valve Maintenance Kit

Global Logistics

We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.

Ingersoll Rand 47550997001 47545136001 Temperature Control Valve Maintenance Kit

Brand new and original

Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.

Ingersoll Rand 47550997001 47545136001 Temperature Control Valve Maintenance Kit

24-hour service

We provide 7*24 hours service to our customers. We will be there whenever you need us.

Ingersoll Rand 47550997001 47545136001 Temperature Control Valve Maintenance Kit

Price advantage

All our products are priced very favorably because we have our own warehouse and supply.


Company Information
E-mail [email protected]
Mobile +8615980777398
Whatsapp +8615980777398
WeChat 15980777398

Product Overview

The Ingersoll Rand 47550997001 47545136001 Temperature Control Valve Maintenance Kit is a service kit for maintaining the temperature control valve in compatible Ingersoll Rand compressor systems. The temperature control valve helps regulate the flow of lubricant through the cooling circuit, supporting control of the compressor’s operating temperature.

During compressor operation, lubricant carries heat away from internal components. The temperature control valve manages lubricant flow through the relevant cooling path according to the system’s temperature conditions. If the valve becomes worn, sticks, or fails to respond correctly, the compressor may experience abnormal oil temperature, inconsistent temperature regulation, or related operating alarms.

A maintenance kit allows service personnel to replace the applicable valve components during scheduled maintenance or troubleshooting. Before ordering or installing the kit, confirm the compressor model, installed valve assembly, and applicable parts documentation. The two part numbers should be checked against the equipment’s bill of materials to ensure the kit is suitable for the specific compressor configuration.


Technical Specifications

Parameter Specification
Product Model 47550997001 / 47545136001
Product Type Temperature Control Valve Maintenance Kit
Manufacturer Ingersoll Rand
Product Category Compressor Service Parts
Component Temperature Control Valve
System Industrial Air Compressor
Function Compressor Lubricant Temperature Regulation
Application Compressor Cooling and Lubrication Circuit
Service Purpose Valve Maintenance and Component Replacement
Operating Role Lubricant Flow Control
Installation Compressor Service Assembly
Maintenance Type Preventive Maintenance / Repair
Dimensions 180 × 140 × 80 mm
Weight 1.20 kg

Product Features

  • Maintenance kit for the temperature control valve in compatible Ingersoll Rand compressor systems
  • Supports servicing of the compressor’s lubricant temperature-control arrangement
  • Helps address valve wear or component deterioration identified during maintenance
  • Intended for use in the compressor cooling and lubrication circuit
  • Suitable for scheduled service and condition-based maintenance
  • Helps restore the intended operation of the temperature control valve when the correct kit is installed
  • Supports maintenance of compressor temperature regulation without automatically requiring replacement of the complete valve assembly
  • Requires verification against the compressor model and installed valve configuration
  • Relevant to compressor service work where oil-temperature behavior or valve condition requires inspection

Working Principle

The temperature control valve operates within the compressor’s lubricant circuit. During operation, the lubricant absorbs heat generated by compression and mechanical movement. The valve regulates the route taken by the lubricant through the cooling arrangement, helping the compressor maintain an appropriate operating temperature.

When the lubricant is below the required operating range, the valve can direct flow through the applicable bypass path. As the lubricant warms, the valve changes the flow distribution so that more lubricant passes through the cooler. The exact routing and actuation mechanism depend on the compressor and valve design.

Compressor Lubricant Circuit → Temperature Control Valve → Bypass / Cooler Flow Path → Lubricant Return to Compressor

The maintenance kit is used when inspection or troubleshooting indicates that serviceable components within the valve assembly need attention. Depending on the kit contents, maintenance may involve replacing internal valve parts or sealing components. The actual contents should be confirmed from the applicable parts list rather than assumed from the product name alone.

After servicing, the valve should be checked for correct assembly, leakage, and proper temperature-control behavior. If abnormal oil temperature continues, the cooling system, lubricant condition, oil filter, cooler, and related controls may also require inspection.


Role in an Ingersoll Rand Compressor Temperature Control System

The maintenance kit supports the temperature control valve, which forms part of the compressor’s lubrication and cooling circuit. The valve helps manage lubricant flow according to operating temperature, while the compressor’s cooler and lubrication components remove and transfer heat.

System Layer Typical Component Function
Compressor Control Compressor Controller Monitors operating conditions and manages compressor operation
Temperature Regulation Temperature Control Valve Directs lubricant through the applicable cooling or bypass path
Service Component 47550997001 / 47545136001 Maintenance Kit Supports maintenance of the temperature control valve
Cooling Oil Cooler Transfers heat from the lubricant to the cooling medium
Lubrication Oil Circuit and Filter Circulates and filters lubricant
Compression Airend / Compressor Element Compresses air and generates operating heat
Monitoring Temperature Sensors Provide temperature information for monitoring and control

Industrial Applications

Application Maintenance Kit Role
Industrial Air Compressors Supports maintenance of the lubricant temperature-control valve
Manufacturing Plants Helps maintain compressor cooling and lubrication performance
Automotive Production Supports compressor service in plant air systems
Food and Beverage Facilities Used during maintenance of compatible compressed-air equipment
Pharmaceutical Manufacturing Supports scheduled service of compressor temperature-control components
Packaging Plants Helps maintain compressor operation in production air systems
Workshops and Industrial Utilities Supports repair and preventive maintenance of compressor equipment
Compressor Overhaul Provides service parts for the applicable temperature control valve assembly

Installation and Maintenance

  1. Confirm compressor compatibility — Verify both part numbers against the compressor model, serial number, and applicable parts documentation.
  2. Identify the installed valve — Confirm the temperature control valve assembly and its position within the compressor lubrication circuit.
  3. Shut down the compressor — Follow the manufacturer’s service procedure and prevent automatic restart before beginning maintenance.
  4. Isolate stored energy — Disconnect the relevant power supply and safely relieve pressure from the affected circuit according to site procedures.
  5. Allow components to cool — Do not open the lubrication circuit while the lubricant or surrounding components remain dangerously hot.
  6. Prepare the work area — Use suitable tools and clean working conditions to prevent contamination of the valve and lubricant circuit.
  7. Inspect the valve assembly — Check for leakage, deposits, damaged sealing surfaces, sticking components, or other signs of deterioration.
  8. Replace the applicable components — Use the kit contents and service instructions to replace only the components specified for the valve assembly.
  9. Check assembly and sealing — Confirm correct component orientation, secure assembly, and proper installation of applicable seals.
  10. Restore the circuit — Reconnect the affected lines and fittings, replenish lubricant if required, and verify that the system is ready for controlled startup.
  11. Test compressor operation — Start the compressor according to the approved procedure and monitor lubricant temperature, leakage, and operating alarms.
  12. Record the maintenance — Document the installed kit part numbers, compressor identification, work performed, lubricant condition, and post-service observations.

Related Components

Component Function
Ingersoll Rand Temperature Control Valve Regulates lubricant flow through the cooling circuit
Oil Cooler Removes heat from the compressor lubricant
Compressor Oil Filter Removes contaminants from circulating lubricant
Compressor Lubricant Transfers heat and lubricates internal components
Oil Separator Separates lubricant from compressed air in applicable compressor designs
Temperature Sensor Monitors lubricant or system temperature
Compressor Controller Monitors operating conditions and manages compressor functions
Compressor Airend Performs the primary air-compression process
Lubrication Circuit Circulates lubricant through the compressor system

Recommended Related Models

Model Product Type Typical Relationship
Ingersoll Rand 47550997001 Temperature Control Valve Maintenance Part Related part number supplied for this maintenance kit
Ingersoll Rand 47545136001 Temperature Control Valve Maintenance Part Related part number supplied for this maintenance kit
Ingersoll Rand Temperature Control Valve Assemblies Compressor Temperature Control Component Associated valve hardware
Ingersoll Rand Oil Cooler Assemblies Compressor Cooling Component Related component in the lubricant cooling circuit
Ingersoll Rand Compressor Oil Filters Compressor Lubrication Component Related service component in the oil circuit

Key Advantages

  • Supports maintenance of the compressor temperature-control valve.
  • Helps address wear in the lubricant temperature-regulation assembly.
  • Suitable for scheduled service and valve-related troubleshooting.
  • Supports continued operation of the compressor cooling and lubrication circuit.
  • Provides a service-parts option when the applicable valve assembly can be maintained.
  • Helps preserve the existing compressor configuration when the correct kit is selected.

Technical FAQs

What is the purpose of the Ingersoll Rand 47550997001 47545136001 maintenance kit?

The kit is intended for maintenance of the temperature control valve in compatible Ingersoll Rand compressor systems. The valve regulates lubricant flow through the cooling circuit to help manage compressor operating temperature.

What symptoms may indicate a temperature control valve problem?

Possible symptoms include abnormal lubricant temperature, slow temperature stabilization, temperature fluctuations, or leakage around the valve. These symptoms can also result from problems with the cooler, lubricant, filter, or other parts of the cooling circuit, so the complete system should be checked.

Should the complete temperature control valve be replaced when using this kit?

Not necessarily. A maintenance kit may allow specified serviceable components to be replaced while retaining the existing valve body. Whether repair is appropriate depends on the valve’s condition, the kit contents, and the compressor manufacturer’s service instructions.

What should be checked after installing the maintenance kit?

Verify correct assembly, sealing, and connections before restarting the compressor. During the controlled startup, check for lubricant leaks, abnormal temperature behavior, and operating alarms. If the temperature remains outside the expected range, inspect the cooler, lubricant condition, oil filter, and related components.



Related Products

Get the latest price? We will reply as soon as possible (within 12 hours)

No:77501