Product Overview The GE UR 8NH is a CT/VT Module used within the GE Multilin UR Series modular protection platform. It forms part of the electrical measurement interface that brings current transformer ……
GE UR 8NH Multilin UR Series CT/VT Module
  • GE
  • UR 8NH
  • CT/VT Module
  • USA
  • 120 × 30 × 100 mm
  • 2.27 kg
  • Xiamen, China
  • New & In Stock
  • T/T, PayPal, Western Union
  • 1 Year
  • 1-3 Working Days
  • DHL, UPS, TNT, FedEx and EMS.
  • 24-Hour Service
  • COO
  • 6

Our advantage

GE UR 8NH Multilin UR Series CT/VT Module

Global Logistics

We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.

GE UR 8NH Multilin UR Series CT/VT Module

Brand new and original

Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.

GE UR 8NH Multilin UR Series CT/VT Module

24-hour service

We provide 7*24 hours service to our customers. We will be there whenever you need us.

GE UR 8NH Multilin UR Series CT/VT Module

Price advantage

All our products are priced very favorably because we have our own warehouse and supply.


Company Information
E-mail [email protected]
Mobile +8615980777398
Whatsapp +8615980777398
WeChat 15980777398

Product Overview

The GE UR 8NH is a CT/VT Module used within the GE Multilin UR Series modular protection platform. It forms part of the electrical measurement interface that brings current transformer and voltage transformer signals into the protection system.

In a typical power-system installation, CTs and VTs provide measurement signals from equipment such as feeders, transformers, generators, motors, and switchgear. The UR 8NH supports the interface between these transformer circuits and the associated UR Series protection hardware, allowing the relay system to work with the electrical measurements required by its configured functions.

For protection engineers and maintenance technicians, the CT/VT interface is also an important point in the overall measurement chain. An abnormal relay reading can originate from the instrument transformer, secondary wiring, terminal connections, interface hardware, or protection configuration. Treating the UR 8NH as part of this complete signal path makes commissioning and fault tracing more systematic.


Technical Specifications

Parameter Specification
Product Model UR 8NH
Product Type CT/VT Module
Product Family Multilin UR Series
Series GE Multilin UR Series
Module Type CT/VT Interface Module
Input Type CT / VT
Measurement Function Current and Voltage Measurement Interface
Signal Source Current Transformer / Voltage Transformer
Application Electrical Protection and Monitoring
System Integration GE Multilin UR Protection Platform
Installation Protection / Control Panel
Interface Role Transformer Signal Interface
Dimensions 120 × 30 × 100 mm
Weight 2.27 kg

Product Features

  • CT/VT signal interface for bringing transformer-derived current and voltage measurements into the UR Series protection architecture.
  • Multilin UR Series compatibility supports modular protection-system installations.
  • Current and voltage measurement path provides the physical interface required for compatible instrument-transformer circuits.
  • Structured panel integration helps organize transformer secondary connections within a protection cabinet.
  • Suitable for protection applications where electrical measurements are required by configured UR Series functions.
  • Useful for measurement diagnostics because the module forms a defined point within the CT/VT signal chain.
  • Modular system architecture allows the CT/VT interface to work as part of a larger protection and control arrangement.

Working Principle

The GE UR 8NH operates within the CT/VT measurement path of a Multilin UR Series protection system. The module provides the interface through which transformer-derived electrical measurements are incorporated into the protection architecture.

1. Primary system measurement

The protected electrical equipment produces the current and voltage conditions being monitored. CTs and VTs convert these primary quantities into suitable secondary measurement circuits.

2. Transformer secondary connection

The CT and VT secondary circuits are routed to the protection panel and connected through the appropriate interface. Correct identification of the circuits is essential because current and voltage transformer circuits have different electrical characteristics and protection requirements.

3. Measurement interface

The UR 8NH forms part of the interface between the CT/VT circuits and the UR Series protection hardware. It provides an organized path for the electrical measurements required by the associated relay functions.

4. Relay measurement processing

The UR Series protection system uses the available current and voltage measurements according to its configured protection and monitoring functions. The actual functions depend on the specific relay application and settings.

5. Protection operation

If measured electrical conditions meet the configured operating criteria, the overall protection system can generate an alarm, trip, or other programmed response. The CT/VT module itself is not the final decision-making element.

6. Troubleshooting path

During commissioning or maintenance, an incorrect measurement can be traced through the complete chain: protected equipment, CT/VT, secondary wiring, terminals, UR 8NH interface, relay measurement, and configuration. This helps determine whether the fault is electrical, wiring-related, hardware-related, or configuration-related.


Role in a Multilin UR Series Protection Architecture

The UR 8NH belongs to the measurement-interface layer of the Multilin UR Series architecture. It connects transformer-derived measurement circuits with the protection platform, while the associated relay hardware performs the configured measurement evaluation and protection functions.

Architecture Layer Typical Function Role of UR 8NH
Protected Equipment Produces the electrical conditions being monitored Source of measured current and voltage
CT / VT Converts primary electrical quantities into secondary signals Provides transformer-derived measurements
CT/VT Interface Routes transformer secondary circuits into protection hardware Provides the interface function
UR Series Protection Hardware Receives and evaluates electrical measurements Uses CT/VT measurement information
Protection Functions Applies configured protection logic Determines the appropriate protection response
Trip / Alarm Circuit Carries the resulting command Acts on the configured relay output

Industrial Applications

Application Typical Use
Electrical Substations Interfacing CT/VT measurements with modular protection equipment
Power Generation Supporting generator-related current and voltage measurement paths
Industrial Power Distribution Connecting feeder measurements to protection systems
Switchgear Protection Providing transformer-derived measurements within protection panels
Transformer Protection Supporting protection schemes requiring current and voltage information
Motor Protection Providing measurement inputs for compatible motor protection arrangements
Utility Protection Integrating CT/VT circuits into modular protection architectures
Process Industry Power Systems Supporting electrical protection and monitoring around plant distribution equipment

Installation and Maintenance

  1. Verify the module model — Confirm that UR 8NH is the correct hardware for the intended Multilin UR Series configuration.
  2. Review the electrical drawings — Identify all CT and VT circuits, terminal assignments, and measurement paths before installation.
  3. Confirm circuit identification — Keep CT and VT conductors clearly separated and matched to the approved wiring documentation.
  4. Follow CT safety procedures — Handle CT secondary circuits according to the applicable electrical safety and testing procedures.
  5. Inspect VT circuits — Check conductors, terminals, circuit protection where applicable, and identification before energization.
  6. Verify polarity and phase relationships — Incorrect polarity or phase association can lead to incorrect protection measurements.
  7. Check grounding arrangements — Confirm that transformer secondary circuits and panel grounding conform to the approved design.
  8. Inspect connection points — Look for loose terminals, damaged insulation, contamination, or other physical conditions that could affect the measurement path.
  9. Verify measured values during commissioning — Compare the values seen by the protection system with the expected transformer secondary measurements.
  10. Check protection configuration — Ensure the associated UR Series settings correspond to the connected CT/VT arrangement.
  11. Trace abnormal signals systematically — Check the instrument transformer, secondary wiring, terminals, module interface, relay measurements, and settings in sequence.
  12. Complete functional testing — Perform the required measurement and protection tests after installation or maintenance before returning the system to service.

Related Components

Component Function
GE Multilin UR Series Protection Relay Processes electrical measurements and executes configured protection functions
Current Transformer (CT) Provides current measurements from the protected power system
Voltage Transformer (VT) Provides voltage measurements for protection and monitoring
CT/VT Secondary Wiring Transfers transformer-derived signals to the protection panel
Protection Control Panel Houses the protection and measurement hardware
Trip Circuit Carries protection commands to switching equipment
Circuit Breaker Interrupts the electrical circuit when commanded by the protection system

Recommended Related Models

Model Product Type Typical Relationship
GE UR 8GH Multilin UR Series CT/VT Ground Protection Module Related CT/VT module for ground protection applications
GE UR 8LH Multilin UR Series CT/VT Module Related CT/VT interface module
GE UR 8C Multilin UR Series CT/VT Module Related transformer measurement interface
GE UR 8D Multilin UR Series Protection Module Related modular UR Series protection hardware

Key Advantages

  • CT/VT interface for Multilin UR Series protection systems
  • Supports structured current and voltage measurement paths
  • Integrates into modular protection-system architectures
  • Suitable for electrical protection and monitoring applications
  • Provides an organized interface for transformer secondary circuits
  • Helps simplify measurement-path troubleshooting and maintenance

Technical FAQs

What is the purpose of the GE UR 8NH module?

The UR 8NH is a CT/VT Module used within the Multilin UR Series architecture. It provides part of the interface path for current- and voltage-transformer-derived measurements used by the associated protection system.

Is the UR 8NH a complete protection relay?

No. The module serves as part of the CT/VT measurement interface. The associated UR Series protection hardware processes the measurements and applies the configured protection functions.

What should be checked if the relay displays an incorrect current or voltage value?

Check the complete measurement path, including the CT or VT, secondary wiring, polarity, phase identification, terminal connections, interface module, and relay configuration. This helps distinguish an external measurement problem from an interface or configuration issue.

What precautions are important when maintaining CT/VT circuits?

CT and VT secondary circuits must be handled according to the applicable electrical safety procedures and the approved protection-system documentation. CT circuits in particular require controlled maintenance practices because improper handling of an energized CT secondary can create hazardous conditions.