• GE UR 8LH Multilin UR Series CT/VT Module
  • GE UR 8LH Multilin UR Series CT/VT Module
  • GE UR 8LH Multilin UR Series CT/VT Module
  • GE UR 8LH Multilin UR Series CT/VT Module
Product Overview The GE UR 8LH is a CT/VT Module used within the GE Multilin UR Series modular protection platform. It forms part of the electrical measurement interface between instrument transformers ……
GE UR 8LH Multilin UR Series CT/VT Module
  • GE
  • UR 8LH
  • CT/VT Module
  • USA
  • 120 × 30 × 100 mm
  • 1.2 kg
  • Xiamen, China
  • New & In Stock
  • T/T, PayPal, Western Union
  • 1 Year
  • 1-3 Working Days
  • DHL, UPS, TNT, FedEx and EMS.
  • 24-Hour Service
  • COO
  • 4

Our advantage

GE UR 8LH Multilin UR Series CT/VT Module

Global Logistics

We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.

GE UR 8LH Multilin UR Series CT/VT Module

Brand new and original

Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.

GE UR 8LH Multilin UR Series CT/VT Module

24-hour service

We provide 7*24 hours service to our customers. We will be there whenever you need us.

GE UR 8LH Multilin UR Series CT/VT Module

Price advantage

All our products are priced very favorably because we have our own warehouse and supply.


Company Information
E-mail [email protected]
Mobile +8615980777398
Whatsapp +8615980777398
WeChat 15980777398

Product Overview

The GE UR 8LH is a CT/VT Module used within the GE Multilin UR Series modular protection platform. It forms part of the electrical measurement interface between instrument transformers and the protection system, allowing current and voltage signals from the protected power equipment to be incorporated into the relay architecture.

In a typical installation, current transformers and voltage transformers provide secondary measurement circuits from feeders, transformers, generators, motors, or other electrical equipment. The UR 8LH provides the corresponding interface within the UR Series hardware structure, while the protection functions use the available measurements according to the configured application.

This type of module is particularly important in protection panels where multiple electrical quantities must be brought into a structured relay architecture. During commissioning and maintenance, technicians can also use the CT/VT signal path to separate transformer-side, wiring-side, and protection-hardware issues when investigating abnormal measurements.


Technical Specifications

Parameter Specification
Product Model UR 8LH
Product Type CT/VT Module
Product Family Multilin UR Series
Series GE Multilin UR Series
Module Type CT/VT Interface Module
Input Type CT / VT
Measurement Function Current and Voltage Measurement Interface
Signal Source Current Transformer / Voltage Transformer
Application Electrical Protection and Monitoring
System Integration GE Multilin UR Protection Platform
Installation Protection / Control Panel
Interface Role Transformer Signal Interface
Dimensions 120 × 30 × 100 mm
Weight 1.2 kg

Product Features

  • CT/VT signal interface connects transformer-derived electrical measurements with the UR Series protection architecture.
  • Multilin UR Series integration supports modular protection-system configurations.
  • Current and voltage measurement path allows the protection platform to work with signals supplied by compatible instrument transformers.
  • Structured panel integration keeps transformer secondary circuits organized within the protection hardware arrangement.
  • Suitable for protection and monitoring applications involving electrical current and voltage measurements.
  • Practical troubleshooting point helps maintenance personnel isolate problems in transformer circuits, wiring, interfaces, and protection logic.
  • Modular architecture compatibility makes the module suitable for systems built around GE Multilin UR Series protection equipment.

Working Principle

The UR 8LH operates as an interface within the CT/VT measurement chain. It does not independently determine the protection response; instead, it makes the appropriate transformer-derived measurements available to the associated UR Series protection system.

1. Electrical measurement

Current transformers and voltage transformers obtain electrical information from the protected equipment. Their secondary circuits carry scaled measurement signals toward the protection panel.

2. CT/VT signal connection

The transformer secondary circuits are connected through the appropriate CT/VT interface. Correct circuit identification, polarity, wiring, and grounding are important because these signals are used directly by protection functions.

3. Measurement transfer

The UR 8LH forms part of the physical measurement path that transfers the CT/VT information into the UR Series protection architecture. The associated protection hardware can then access the required electrical measurements.

4. Protection processing

The UR Series relay processes the available measurements according to its configured protection functions. Depending on the application, these measurements may support functions such as current protection, voltage-related protection, ground-related protection, monitoring, or other configured electrical protection tasks.

5. Protection response

When the measured conditions satisfy the configured operating criteria, the overall protection system can generate the appropriate alarm, trip, or control response. The actual response depends on the relay configuration and the electrical protection scheme.

6. Diagnostic path

When measurements appear incorrect, technicians can trace the complete path from the protected equipment through the CT/VT secondary circuits, wiring, interface module, and protection configuration. This helps distinguish a field measurement problem from an interface or relay-configuration issue.


Role in a Multilin UR Series Protection Architecture

The UR 8LH occupies the CT/VT measurement-interface layer of a modular Multilin UR Series protection system. Instrument transformers provide the electrical measurements, while the module forms part of the connection path into the protection platform.

Architecture Layer Typical Function Role of UR 8LH
Protected Electrical Equipment Generates the electrical quantities being monitored Source of measured current and voltage
Current / Voltage Transformers Convert primary electrical quantities into protection-system measurements Provides CT/VT secondary signals
CT/VT Interface Connects transformer secondary circuits with protection hardware Provides the CT/VT interface
UR Series Protection Platform Processes electrical measurements Receives available measurement information
Protection Functions Evaluates configured electrical conditions Uses measurement data for protection and monitoring
Trip / Alarm Circuit Carries the resulting protection command Acts on the configured protection response

Industrial Applications

Application Typical Use
Electrical Substations Connecting CT/VT measurements to modular protection equipment
Power Generation Providing current and voltage measurement paths for generator protection systems
Industrial Distribution Supporting protection of plant feeders and electrical distribution equipment
Motor Protection Supplying transformer-derived measurements required by compatible protection schemes
Transformer Protection Integrating current and voltage measurements into protection architectures
Switchgear Providing CT/VT measurement interfaces inside protection and control panels
Utility Protection Supporting structured measurement paths in utility electrical protection systems
Process Plants Connecting electrical protection measurements to plant power-management equipment

Installation and Maintenance

  1. Verify the module model — Confirm that UR 8LH matches the approved protection-system hardware configuration before installation.
  2. Review the protection drawings — Identify the intended CT and VT circuits, terminal assignments, and signal paths before connecting the module.
  3. Separate CT and VT circuits correctly — Confirm each conductor and circuit against the electrical documentation to prevent incorrect connections.
  4. Follow CT safety procedures — CT secondary circuits require appropriate isolation and handling procedures during testing and maintenance.
  5. Check VT circuit connections — Inspect wiring, terminals, fusing where applicable, and circuit identification according to the approved design.
  6. Verify polarity and phase identification — Incorrect polarity or phase association can produce misleading measurements and affect protection operation.
  7. Inspect grounding arrangements — Confirm that the CT/VT circuits and panel grounding follow the applicable electrical design.
  8. Check terminal condition — Look for loose connections, damaged conductors, contamination, or other physical issues that could affect measurement quality.
  9. Verify expected measurements — During commissioning, compare available protection-system measurements with the expected secondary-side electrical conditions.
  10. Review relay configuration — Make sure the associated UR Series protection functions are configured consistently with the connected measurement circuits.
  11. Trace faults systematically — If a measurement is abnormal, inspect the transformer, secondary wiring, terminals, module interface, and relay configuration in sequence.
  12. Perform functional testing — After installation or maintenance, complete the applicable CT/VT and protection-system tests before placing the equipment back into service.

Related Components

Component Function
GE Multilin UR Series Protection Relay Processes electrical measurements and executes configured protection functions
Current Transformer (CT) Provides current measurements from the protected electrical system
Voltage Transformer (VT) Provides voltage measurements for the protection system
CT/VT Secondary Wiring Transfers transformer-derived measurement signals to the protection panel
Protection Control Panel Provides the physical installation environment for protection equipment
Trip Circuit Carries protection commands to associated switching equipment
Circuit Breaker Interrupts the protected circuit when commanded by the protection system

Recommended Related Models

Model Product Type Typical Relationship
GE UR 8GH Multilin UR Series CT/VT Ground Protection Module Related CT/VT module for ground protection applications
GE UR 8C Multilin UR Series CT/VT Module Related transformer measurement interface
GE UR 8D Multilin UR Series Protection Module Related modular protection hardware
GE UR 8F Multilin UR Series Protection Module Related UR Series protection hardware

Key Advantages

  • CT/VT interface for Multilin UR Series protection systems
  • Supports structured current and voltage measurement paths
  • Integrates with modular UR Series protection architecture
  • Suitable for protection and electrical monitoring applications
  • Simplifies organization of CT/VT circuits within protection panels
  • Provides a defined point for measurement-path troubleshooting

Technical FAQs

What is the function of the GE UR 8LH module?

The UR 8LH is a CT/VT Module used within the Multilin UR Series architecture. It forms part of the interface path for current- and voltage-transformer-derived measurements used by the associated protection system.

Does the UR 8LH itself perform the complete protection function?

No. The module is part of the measurement interface. The associated UR Series protection platform processes the available electrical measurements and applies the configured protection logic.

What can cause an incorrect CT or VT measurement?

Potential causes include incorrect wiring, polarity or phase identification, loose terminals, transformer-side issues, grounding problems, interface problems, or an incorrect protection-system configuration. Troubleshooting should follow the complete measurement path rather than immediately replacing the module.

What should be verified before replacing a UR 8LH?

The replacement should be checked against the approved UR Series hardware configuration and electrical drawings. CT/VT circuit identification, wiring, terminal assignments, grounding, and the associated protection configuration should all be verified before the system is returned to service.



Related Products

Get the latest price? We will reply as soon as possible (within 12 hours)

No:77501