• GE UR 5EH Multilin UR Transducer I/O Module
  • GE UR 5EH Multilin UR Transducer I/O Module
  • GE UR 5EH Multilin UR Transducer I/O Module
  • GE UR 5EH Multilin UR Transducer I/O Module
Product Overview The GE UR 5EH is a Multilin UR Transducer I/O Module used within GE Multilin Universal Relay systems to interface transducer-related signals with the protection and control platform. It……
GE UR 5EH Multilin UR Transducer I/O Module
  • GE
  • UR 5EH
  • Transducer I/O Module
  • USA
  • 120 × 30 × 100 mm
  • 1.15 kg
  • Xiamen, China
  • New & In Stock
  • T/T, PayPal, Western Union
  • 1 Year
  • 1-3 Working Days
  • DHL, UPS, TNT, FedEx and EMS.
  • 24-Hour Service
  • COO
  • 4

Our advantage

GE UR 5EH Multilin UR Transducer I/O Module

Global Logistics

We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.

GE UR 5EH Multilin UR Transducer I/O Module

Brand new and original

Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.

GE UR 5EH Multilin UR Transducer I/O Module

24-hour service

We provide 7*24 hours service to our customers. We will be there whenever you need us.

GE UR 5EH Multilin UR Transducer I/O Module

Price advantage

All our products are priced very favorably because we have our own warehouse and supply.


Company Information
E-mail [email protected]
Mobile +8615980777398
Whatsapp +8615980777398
WeChat 15980777398

Product Overview

The GE UR 5EH is a Multilin UR Transducer I/O Module used within GE Multilin Universal Relay systems to interface transducer-related signals with the protection and control platform. It provides the signal interface required when measured process or electrical quantities need to be brought into the relay system for monitoring, control, or automation functions.

In a typical substation or industrial power system, transducer signals may originate from external measurement devices and then be routed through the I/O architecture to the protection relay. The module provides the connection between these field signals and the UR platform, allowing the associated relay application to use the information alongside its protection and control functions.

The module is particularly relevant in applications where protection, measurement, automation, and control functions are combined in a single Multilin UR-based system.


Technical Specifications

Parameter Specification
Product Model UR 5EH
Product Type Multilin UR Transducer I/O Module
Series Multilin UR
I/O Function Transducer Signal Interface
Dimensions 120 × 30 × 100 mm
Weight 1.15 kg

Product Features

  • Transducer I/O interface — Connects transducer-related signals with the Multilin UR platform.
  • UR-series integration — Forms part of the modular I/O architecture used by GE Multilin Universal Relay systems.
  • Measurement signal handling — Supports the relay system’s use of externally generated transducer information.
  • Protection and control integration — Allows transducer information to participate in broader relay automation functions.
  • Modular I/O architecture — Can be incorporated into a UR relay configuration according to the application’s I/O requirements.
  • Substation-oriented application — Suited to electrical protection, monitoring, and control systems where transducer signals must be integrated into the relay platform.

Working Principle

The UR 5EH operates as an I/O interface between external transducer circuits and the Multilin UR relay platform. Signals generated by the connected transducer circuitry enter the module through the appropriate interface and are made available to the relay’s internal processing and application functions.

The UR relay can then use the acquired information for functions such as measurement, monitoring, control logic, automation, or event analysis, depending on the configured application. The module itself should therefore be viewed as part of the signal path rather than as the primary protection processor.

During commissioning, technicians typically verify the external transducer wiring, module connections, relay configuration, and measured values together. If the expected value is missing or incorrect, checking each stage of this signal path helps determine whether the problem originates at the transducer, wiring, I/O interface, or relay configuration.


Role in a GE Multilin UR Protection and Control Architecture

Architecture Layer Role of UR 5EH
External Transducer Produces the measurement or transducer signal
Field Wiring Carries the signal toward the relay I/O
UR 5EH Provides the transducer signal interface
Multilin UR Relay Processes the available input information
Protection / Automation Logic Uses measurements within configured functions
HMI / SCADA Displays or communicates relevant relay information
Control Equipment Receives control actions generated by the relay system

The UR 5EH occupies the I/O layer of the architecture, connecting external measurement signals to the relay’s processing and application environment.


Industrial Applications

Application Typical Use
Substation Protection Bringing transducer-related measurements into a UR relay system
Switchgear Monitoring Integrating external measurement signals with relay monitoring functions
Generator Protection Providing additional measurement interfaces for protection and control applications
Motor Protection Supporting transducer signal integration in motor-control systems
Feeder Protection Connecting measurement signals to a Multilin UR feeder relay configuration
Industrial Power Distribution Combining electrical monitoring with protection and automation
SCADA Integration Making transducer-related information available to higher-level monitoring systems through the UR platform

Installation and Maintenance

  1. Verify the I/O configuration — Confirm that the UR 5EH matches the transducer interface required by the specific Multilin UR application.
  2. Review the wiring diagram — Identify the transducer, field conductors, module terminals, and corresponding relay input assignments.
  3. Isolate the relevant circuits — Follow site safety procedures before working on the relay I/O or connected field wiring.
  4. Check module identification — Verify the module designation before installing it into the UR relay assembly.
  5. Inspect the module interface — Check for damaged connectors, contamination, or abnormal mechanical conditions.
  6. Inspect transducer wiring — Look for loose terminals, broken conductors, incorrect connections, or signs of electrical damage.
  7. Verify relay configuration — Confirm that the software configuration corresponds to the installed I/O arrangement.
  8. Check signal continuity — Verify that the expected transducer signal reaches the appropriate I/O interface.
  9. Compare measured values — Compare relay readings with the expected value from the external measurement system.
  10. Investigate abnormal readings — Trace the signal path from the transducer through the wiring and I/O module before replacing components.
  11. Perform functional testing — Confirm that the relay correctly recognizes and processes the transducer input during commissioning.
  12. Document configuration changes — Record module replacement, wiring modifications, configuration changes, and test results.

Compatible System Components

Component Relationship
GE Multilin UR Relays Host protection and control platform for the I/O module
GE Multilin UR I/O Modules Related modules used to expand or customize relay interfaces
External Transducers Provide the signals connected to the module
Current / Voltage Measurement Devices Potential sources of electrical measurement information
SCADA Systems Receive monitoring and measurement information from the relay system
Substation Control Equipment Uses relay information for protection and automation functions
Communication Interfaces Connect the UR relay to higher-level monitoring and control networks

Recommended Related Models

Model Product Type Application Relationship
GE UR 5EH Multilin UR Transducer I/O Module Transducer signal interface for UR relay systems
GE Multilin UR I/O Modules Universal Relay I/O Module Related I/O options for configuring UR relay interfaces
GE Multilin UR Protection Relays Protection Relay Host platform for modular I/O and protection functions
GE Multilin UR Feeder Relays Feeder Protection Relay Related application platform for substation feeder protection
GE Multilin UR Generator Relays Generator Protection Relay Related UR platform for generator protection and control

Key Advantages

  • Provides a dedicated interface for transducer-related signals in a Multilin UR system.
  • Integrates external measurement information with relay protection and control functions.
  • Supports modular configuration of the UR relay I/O architecture.
  • Simplifies signal-path troubleshooting between field measurement devices and relay processing.
  • Fits applications combining measurement, protection, monitoring, and automation.
  • Supports existing GE Multilin UR-based electrical control and protection installations.

Technical FAQs

What is the function of the GE UR 5EH?

The UR 5EH is a Multilin UR Transducer I/O Module that provides an interface between external transducer-related signals and the GE Multilin UR relay platform.

Does the UR 5EH perform the main protection calculations?

The module serves primarily as an I/O interface. Protection and control processing is performed by the host Multilin UR relay according to its configured functions and application.

What should be checked if the UR relay does not display the expected transducer value?

Check the external transducer, field wiring, module connections, relay I/O configuration, and signal assignments. Comparing the signal at different points in the path can help identify whether the issue is external to the relay or within the I/O configuration.

Can the UR 5EH be replaced without checking the relay configuration?

The physical replacement should be followed by verification of the relay’s I/O configuration and application settings. The installed module and the configured I/O arrangement should correspond before the system is returned to service.



Related Products

Get the latest price? We will reply as soon as possible (within 12 hours)

No:77501