Product Overview The Schneider TM3DQ16R is a 16-channel discrete output module for the Modicon TM3 platform, using relay outputs to interface a Modicon controller with external devices. It is suited to ……
Schneider TM3DQ16R Modicon TM3 Discrete Output Module
  • Schneider
  • TM3DQ16R
  • Discrete Output Module
  • France
  • 90 × 84.6 × 27.4 mm
  • 0.145 kg
  • Xiamen, China
  • New & In Stock
  • T/T, PayPal, Western Union
  • 1 Year
  • 1-3 Working Days
  • DHL, UPS, TNT, FedEx and EMS.
  • 24-Hour Service
  • COO
  • 5

Our advantage

Schneider TM3DQ16R Modicon TM3 Discrete Output Module

Global Logistics

We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.

Schneider TM3DQ16R Modicon TM3 Discrete Output Module

Brand new and original

Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.

Schneider TM3DQ16R Modicon TM3 Discrete Output Module

24-hour service

We provide 7*24 hours service to our customers. We will be there whenever you need us.

Schneider TM3DQ16R Modicon TM3 Discrete Output Module

Price advantage

All our products are priced very favorably because we have our own warehouse and supply.


Company Information
E-mail [email protected]
Mobile +8615980777398
Whatsapp +8615980777398
WeChat 15980777398

Product Overview

The Schneider TM3DQ16R is a 16-channel discrete output module for the Modicon TM3 platform, using relay outputs to interface a Modicon controller with external devices. It is suited to machine control panels where several independent ON/OFF loads need to be switched from the PLC program.

In a packaging machine, for example, the module can control solenoid valves, contactors, signal lamps, buzzers, and interposing relays according to the machine sequence. In a conveyor system, individual outputs can be assigned to motor-control circuits, pneumatic actuators, stack lights, or auxiliary equipment. The 16-channel arrangement is useful when the controller needs a relatively high number of discrete output points in one expansion module.

Because the outputs are relay-based, the module can be used for different types of suitable external circuits rather than being limited to a single transistor output switching arrangement. The actual voltage, current, load type, switching frequency, and common-circuit requirements should be checked before connecting field loads.

The TM3DQ16R is intended for compatible Modicon controllers and fits into the modular TM3 expansion architecture. For retrofit work, the existing output address assignment and field wiring should be documented before replacing the module so each controlled device remains mapped to the intended PLC output.


Technical Specifications

ParameterSpecification
Manufacturer Schneider Electric
Model TM3DQ16R
Product Family Modicon TM3
Product Type Discrete Output Module
Number of Outputs 16
Output Type Relay
Output Contact Type Normally Open (NO)
Output Voltage 24 V DC / 240 V AC
Output Current 2 A per output
Output Common Current 7 A maximum per common line
Connection Type Removable screw terminal block
Output Turn-On Time Max. 10 ms
Output Turn-Off Time Max. 10 ms
Protection Degree IP20
Compatible Controllers Modicon M221 / M241 / M251 / M262
Dimensions 90 × 84.6 × 27.4 mm
Weight 0.145 kg

Product Features

  • Modicon TM3 discrete output module
  • 16 relay output channels
  • Normally open relay contacts
  • Supports suitable 24 V DC and 240 V AC output circuits
  • 2 A rated current per output
  • 7 A maximum current per output common line
  • Removable screw terminal connection
  • Suitable for controlling discrete actuators and auxiliary circuits
  • Compatible with Modicon M221, M241, M251, and M262 controllers
  • Useful for applications requiring multiple relay-controlled output points
  • Suitable for machine automation and equipment control

Working Principle

The TM3DQ16R receives output commands from the Modicon controller and uses its relay contacts to switch the corresponding external circuits.

Modicon Controller → TM3DQ16R → Relay Contact → Field Load

When the PLC program commands an output channel ON, the corresponding relay changes state and closes its normally open contact. This allows the connected control circuit to energize a suitable load such as a solenoid valve, contactor coil, indicator, or interposing relay.

When the command is removed, the relay returns to its normal state and interrupts the associated circuit.

The module therefore acts as the switching interface between the controller’s output logic and the machine’s external devices. For applications with several actuators, each relay channel can be assigned to a specific function in the PLC program, such as valve extension, motor enable, alarm lamp, conveyor control, or auxiliary equipment.


Role in a Modicon TM3 Control Architecture

The TM3DQ16R occupies the output side of a Modicon TM3 control system, translating PLC output commands into switched field circuits.

PLC Program → Modicon Controller → TM3DQ16R → Relay Outputs → Contactors / Valves / Indicators / Other Loads

System ElementFunction
Modicon Controller Executes the machine control program
TM3DQ16R Provides 16 relay output channels
Relay Contact Switches the external control circuit
Solenoid Valve Converts an electrical command into actuator movement
Contactor Controls suitable motor or power circuits
Interposing Relay Interfaces the PLC output with another circuit
Indicator Lamp Displays machine or equipment status
Alarm / Buzzer Provides discrete operator notification

The output assignment depends on the application program and electrical design. Each field load should be matched to the appropriate output channel and relay operating limits.


Industrial Applications

ApplicationTypical Use
Packaging Machinery Solenoid valves, indicators, and auxiliary control
Conveyor Systems Motor-control signals and equipment commands
Assembly Machines Pneumatic actuator and workstation control
Material Handling Discrete actuator and equipment switching
Machine Tools Auxiliary devices, valves, lamps, and control circuits
Pump Skids Contactors, valves, alarms, and auxiliary equipment
Production Lines Multiple discrete machine outputs
Motor Control Panels Contactor and auxiliary relay control
HVAC Equipment Fan, valve, damper, and alarm control circuits
Equipment Retrofit Projects Expansion of relay-based digital output capacity

Installation and Maintenance

  1. Confirm that the TM3DQ16R is supported by the installed Modicon controller and TM3 configuration.
  2. Verify that the machine application requires relay outputs rather than another output technology.
  3. Check the voltage and current requirements of every connected field load before wiring.
  4. Confirm that each output remains within the specified relay and common-line current limits.
  5. Identify the PLC output address assigned to every field device before replacing an existing module.
  6. Use the removable screw terminal connections according to the electrical design of the machine.
  7. Keep output wiring appropriately separated from high-power motor and drive cables where practical.
  8. Label each output channel according to the connected actuator, contactor, valve, lamp, or auxiliary device.
  9. During commissioning, activate each output individually and verify the corresponding field device response.
  10. Check relay operation if an output command is present but the connected load does not energize.
  11. Inspect the load circuit, fuse or protection device, terminal connection, and external device before assuming that the I/O module has failed.
  12. During maintenance, check relay-controlled circuits for loose connections, abnormal heating, contact wear, or loads that exceed the intended operating conditions.

Related Components

ComponentFunction
Modicon M221 Controller Compact controller for TM3 output expansion
Modicon M241 Controller Machine controller with TM3 I/O expansion
Modicon M251 Controller Controller for modular machine automation
Modicon M262 Controller Logic and motion controller with TM3 I/O
Solenoid Valve Discrete actuator controlled by relay output
Contactor Switches suitable motor or power circuits
Interposing Relay Provides an interface between control and field circuits
Indicator Lamp Provides visual equipment status
Buzzer / Alarm Device Provides discrete operator notification
TM3 Digital Input Module Provides field status signals to the controller

Recommended Related Models

Model / Product FamilyProduct Type Typical Application
Schneider TM3DQ8R Smaller relay-output applications
Schneider TM3DQ16T 16-channel transistor output applications
Schneider TM3DQ32TK Higher-density transistor output expansion
Schneider TM3DI16 Applications requiring additional digital inputs
Schneider TM3DM24R Mixed input and relay output applications
Schneider Modicon M221 Compact controller with TM3 expansion
Schneider Modicon M241 Machine controller for larger TM3 I/O configurations

Key Advantages

  • 16 relay output channels.
  • Supports suitable DC and AC discrete control circuits.
  • 2 A rated current per output.
  • Removable screw terminal connection.
  • Suitable for multiple actuator and auxiliary control points.
  • Integrates with the Modicon TM3 architecture.
  • Compatible with several Modicon controller families.

Technical FAQs

What type of loads can the TM3DQ16R control?

The relay outputs can be used for suitable discrete loads and control circuits, including solenoid valves, contactor coils, indicator devices, buzzers, and interposing relays. The actual load must remain within the applicable relay voltage and current limits.

Why would a relay output module be selected instead of a transistor output module?

Relay outputs can be useful when the application requires relay contacts or needs to switch suitable DC or AC control circuits. Transistor outputs are generally used for applications with different switching requirements, so the load type and switching characteristics should be considered during selection.

How should the 16 outputs be assigned in a machine program?

Each physical output should be mapped to a clearly defined machine function in the PLC program and electrical drawings. Typical assignments include solenoid valves, contactor coils, indicator lamps, alarms, and auxiliary equipment. Consistent channel documentation makes commissioning and troubleshooting easier.

What should be checked if one TM3DQ16R output does not activate its load?

First verify that the PLC program is commanding the correct output channel. Then check the output status, terminal connection, relay contact circuit, external power supply, protection devices, and field load. If the command and module status are correct but the load remains inactive, the problem may be in the external circuit rather than the controller program.



Related Products

Get the latest price? We will reply as soon as possible (within 12 hours)

No:77501