• Schneider TM3DI16G Modicon TM3 Discrete Input Module
  • Schneider TM3DI16G Modicon TM3 Discrete Input Module
  • Schneider TM3DI16G Modicon TM3 Discrete Input Module
  • Schneider TM3DI16G Modicon TM3 Discrete Input Module
Product Overview The Schneider TM3DI16G is a Modicon TM3 Discrete Input Module used to expand the digital input capacity of compatible Modicon controllers. It provides 16 discrete input channels for col……
Schneider TM3DI16G Modicon TM3 Discrete Input Module
  • Schneider
  • TM3DI16G
  • Discrete Input Module
  • France
  • 90 × 84.6 × 27.4 mm
  • 0.1 kg
  • Xiamen, China
  • New & In Stock
  • T/T, PayPal, Western Union
  • 1 Year
  • 1-3 Working Days
  • DHL, UPS, TNT, FedEx and EMS.
  • 24-Hour Service
  • COO
  • 5

Our advantage

Schneider TM3DI16G Modicon TM3 Discrete Input Module

Global Logistics

We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.

Schneider TM3DI16G Modicon TM3 Discrete Input Module

Brand new and original

Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.

Schneider TM3DI16G Modicon TM3 Discrete Input Module

24-hour service

We provide 7*24 hours service to our customers. We will be there whenever you need us.

Schneider TM3DI16G Modicon TM3 Discrete Input Module

Price advantage

All our products are priced very favorably because we have our own warehouse and supply.


Company Information
E-mail [email protected]
Mobile +8615980777398
Whatsapp +8615980777398
WeChat 15980777398

Product Overview

The Schneider TM3DI16G is a Modicon TM3 Discrete Input Module used to expand the digital input capacity of compatible Modicon controllers. It provides 16 discrete input channels for collecting ON/OFF signals from field devices such as push buttons, selector switches, limit switches, proximity sensors, and auxiliary contacts.

In a machine control panel, the TM3DI16G serves as the interface between field-level switching devices and the controller. Each input channel reports the state of its connected device to the controller, allowing the control program to use these signals for sequencing, interlocking, machine status detection, alarms, and operator commands.

The module is suited to applications where additional digital input points are required within a modular Modicon TM3 architecture. It can be used alongside other TM3 I/O modules to build an I/O configuration matched to the number and type of field signals in the machine.


Technical Specifications

Parameter Specification
Manufacturer Schneider Electric
Model TM3DI16G
Product Family Modicon TM3
Product Type Discrete Input Module
Number of Inputs 16
Input Type Discrete
Signal Function ON/OFF field signal acquisition
Application PLC digital input expansion
Dimensions 90 × 84.6 × 27.4 mm
Weight 0.1 kg

Product Features

  • Provides 16 discrete input channels for compatible Modicon control systems.
  • Expands controller input capacity without changing the main controller.
  • Receives ON/OFF status signals from industrial field devices.
  • Suitable for switches, push buttons, limit devices, proximity sensors, and auxiliary contacts.
  • Supports machine sequence, status, alarm, and interlock signals.
  • Fits into a modular Modicon TM3 expansion architecture.
  • Can be combined with other TM3 I/O modules according to the application’s signal requirements.

Working Principle

The TM3DI16G receives discrete electrical signals from connected field devices and determines the state of each input channel.

The basic signal path is:

Field Device → TM3DI16G Discrete Input → Modicon Controller → Control Logic

When a field device changes between its defined ON and OFF states, the corresponding input channel detects the change and communicates the input status to the controller. The controller then processes the signal according to the application program.

For example, a proximity sensor can provide a part-detection signal, a limit switch can confirm the position of a moving mechanism, and a push button can provide an operator command. The controller can combine these signals with timers, interlocks, and output commands to execute the required machine sequence.


Role in a Modicon TM3 Control Architecture

The TM3DI16G provides the discrete signal acquisition layer between field devices and the controller.

System Element Function
Push Buttons / Selector Switches Provide operator commands
Proximity / Limit Sensors Detect machine position or object presence
TM3DI16G Collects 16 discrete input signals
Modicon Controller Processes input states through the control program
TM3 Expansion Architecture Adds modular I/O capacity
Digital Output Modules Send control commands to external devices
HMI Displays machine status and operator information
Actuators Execute physical machine actions

The module handles field signal acquisition while the controller determines how each input affects the machine’s operating sequence.


Industrial Applications

  • Automated machine control
  • Packaging machinery
  • Conveyor and material handling systems
  • Assembly equipment
  • Pump and motor control panels
  • Machine position detection
  • Operator push-button interfaces
  • Industrial equipment status monitoring
  • PLC digital input expansion
  • General-purpose discrete signal acquisition

Installation and Maintenance

  1. Verify controller compatibility — Confirm that the TM3DI16G is supported by the intended Modicon controller and TM3 expansion configuration.
  2. Assign the input channels — Define which field device is connected to each input before completing the wiring.
  3. Check field signal characteristics — Verify that each connected device provides the appropriate discrete signal for the input circuit.
  4. Install the module securely — Ensure that the module is correctly mounted and properly connected to the TM3 expansion system.
  5. Check terminal wiring — Confirm that each field signal and its corresponding reference connection are wired to the correct terminals.
  6. Organize signal cables — Keep input wiring properly routed and separated from potential sources of excessive electrical interference.
  7. Label each input — Identify each channel according to the associated sensor, switch, command, or machine status signal.
  8. Test individual channels — Operate each field device during commissioning and verify that the corresponding input state changes correctly.
  9. Check controller addressing — Confirm that the controller program uses the correct input addresses for the TM3DI16G channels.
  10. Inspect wiring during maintenance — Check terminals, connectors, and field wiring for looseness, corrosion, or physical damage.
  11. Troubleshoot abnormal channels systematically — Check the field device, wiring, reference connection, and input status before determining whether the module itself requires replacement.
  12. Maintain I/O documentation — Keep the input assignment list and control documentation synchronized with the actual machine wiring.

Related Components

  • Schneider Modicon TM3 controller systems
  • Modicon TM3 digital input modules
  • Modicon TM3 digital output modules
  • Modicon TM3 analog I/O modules
  • Modicon M221 controllers
  • Modicon M241 controllers
  • Modicon M251 controllers
  • Proximity sensors
  • Limit switches
  • Push buttons and selector switches
  • Machine control HMIs

Recommended Related Models

  • Schneider Modicon TM3 Digital Input Modules
  • Schneider Modicon TM3 Digital Output Modules
  • Schneider Modicon TM3 Mixed I/O Modules
  • Schneider Modicon M221 Controllers
  • Schneider Modicon M241 Controllers
  • Schneider Modicon M251 Controllers

Key Advantages

  • Provides 16 discrete input channels for controller expansion.
  • Simplifies connection of additional digital field signals.
  • Suitable for machine commands, status signals, and position detection.
  • Supports modular TM3 I/O configurations.
  • Can be integrated with sensors, switches, and operator devices.
  • Provides a direct interface between field devices and controller logic.

Technical FAQs

What is the TM3DI16G used for?

The TM3DI16G is used to add discrete input capacity to compatible Modicon control systems. It receives ON/OFF signals from field devices and makes their states available to the controller.

What field devices can be connected to the module?

Typical applications include push buttons, selector switches, limit switches, proximity sensors, and auxiliary contacts. The electrical specifications of the field devices should be verified before installation.

What is the difference between TM3DI16G and a digital output module?

The TM3DI16G receives signals from field devices and passes their states to the controller. A digital output module sends control signals from the controller to external loads or actuating devices.

How should an input fault be diagnosed?

Start at the field device and work toward the controller: check the device state, wiring, reference connection, terminal condition, and controller input status. If the expected field signal reaches the module but the controller still reports an incorrect state, the module connection and I/O configuration should be investigated.



Related Products

Get the latest price? We will reply as soon as possible (within 12 hours)

No:77501