Our advantage
Global Logistics
We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.
Brand new and original
Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.
24-hour service
We provide 7*24 hours service to our customers. We will be there whenever you need us.
Price advantage
All our products are priced very favorably because we have our own warehouse and supply.
| Company Information | |||
| [email protected] | |||
| Mobile | +8615980777398 | ||
| +8615980777398 | |||
| 15980777398 |

The Allen-Bradley 20G1ALF500JN4NNNNN is a high-power PowerFlex 755 AC variable-frequency drive designed for large three-phase industrial motor applications.
It is part of the air-cooled PowerFlex 755 drive family and is intended for applications requiring high motor current, adjustable speed, controlled acceleration, controlled deceleration and integration with an industrial automation system.
The drive is rated for 690 VAC, three-phase input with a 500 A current rating.
Its published power ratings are:
The unit uses a Frame 8 high-power mechanical configuration and an 800 mm deep MCC-style arrangement.
The drive is air cooled and uses forced airflow to remove heat from the power section during operation.
The configuration includes embedded EtherNet/IP, allowing the drive to be integrated into a networked industrial control system.
The input arrangement is AC input with precharge and no DC terminals. The configuration is also identified as filtered, with the corresponding CM-jumper configuration specified by the JN4 catalog number.
The model is intended for large motor applications such as pumps, fans, blowers, conveyors, compressors, mining equipment, water systems, cement equipment and other high-power industrial machinery.
| Item | Description |
|---|---|
| Brand | Allen-Bradley |
| Product Family | PowerFlex |
| Series | PowerFlex 755 |
| Product Type | AC Variable-Frequency Drive |
| Model | 20G1ALF500JN4NNNNN |
| Drive Type | High-Power Industrial AC Drive |
| Cooling | Air Cooled / Forced Air |
| Frame | Frame 8 |
| Input Voltage | 690 VAC |
| Input Phase | 3 Phase |
| Rated Current | 500 A |
| LD Rating | 530 kW |
| ND Rating | 500 kW |
| HD Rating | 400 kW |
| Communication | Embedded EtherNet/IP |
| Input Configuration | AC Input with Precharge |
| DC Terminals | None |
| Filter | Filtered |
| Mechanical Style | MCC Style |
| Mechanical Depth | 800 mm |
| Enclosure Class | Type 1 / IP20 |
| Intended Application | Large Industrial AC Motor Control |
| Parameter | Specification |
|---|---|
| Model | 20G1ALF500JN4NNNNN |
| Brand | Allen-Bradley |
| Series | PowerFlex 755 |
| Product Category | AC Variable-Frequency Drive |
| Product Type | High-Power AC Drive |
| Input Voltage | 690 VAC |
| Input Phase | 3 Phase |
| Rated Current | 500 A |
| Light-Duty Rating | 530 kW |
| Normal-Duty Rating | 500 kW |
| Heavy-Duty Rating | 400 kW |
| Frame Size | Frame 8 |
| Cooling | Air Cooled / Forced Air |
| Input Type | AC Input with Precharge |
| DC Terminals | None |
| Filtering | Filtered |
| Communication | Embedded EtherNet/IP |
| Mechanical Style | MCC Style |
| Mechanical Depth | 800 mm |
| Enclosure | Type 1 / IP20 |
| CM Jumper | Configuration-specific JN4 arrangement |
| Dynamic Braking | Configuration-specific; verify final order code |
| HIM Configuration | JN4 configuration; verify final supplied interface |
| Approx. Height* | 2453 mm |
| Approx. Width* | 600 mm |
| Approx. Depth | 800 mm |
| Approx. Weight* | 623 kg |
| Mounting | Floor-standing / MCC-style installation |
| Cooling Airflow | Forced Air |
| Typical Motor Class | Large Industrial AC Motors |
| Typical Applications | Pumps, fans, blowers, conveyors, compressors and process machinery |
*The listed height, width and weight are approximate planning values for the Frame 8 MCC-style configuration. They should not replace the final mechanical drawing or shipping documentation for the exact unit.
The 20G1ALF500JN4NNNNN is a 690 VAC, three-phase, 500 A PowerFlex 755 drive.
This combination places the model in the high-power section of the product family.
The drive is designed for large AC motors where the electrical system requires a high current rating and the process requires adjustable motor speed.
The principal power ratings are:
| Duty Class | Rated Power |
|---|---|
| Light Duty | 530 kW |
| Normal Duty | 500 kW |
| Heavy Duty | 400 kW |
The appropriate rating depends on the actual application rather than simply the motor nameplate kW.
The 530 kW Light-Duty rating is the highest published power rating for this 500 A configuration.
Light-Duty operation is generally associated with applications where the motor load does not require the highest continuous torque and overload capability.
Typical examples include large centrifugal pumps, fans and blowers.
The actual motor current must still remain within the applicable drive rating.
The 500 kW Normal-Duty rating provides a general-purpose reference for industrial motor applications.
Potential applications include:
Motor current, load torque and operating conditions should be checked before final selection.
The 400 kW Heavy-Duty rating is applicable to more demanding motor-load conditions.
Examples can include:
Heavy-Duty selection should be based on the actual motor current and load profile.
The 690 VAC voltage class is intended for large industrial motor systems.
Higher motor voltage can reduce current for a given motor power compared with a lower-voltage system.
This can affect the overall design of:
The actual plant supply voltage should be confirmed before installation.
The 500 A rating is one of the main characteristics of this model.
A drive at this current level requires proper electrical engineering.
The installation should account for:
The 500 A drive rating should not be used by itself to determine the upstream protective-device rating.
The Frame 8 configuration is intended for high-power industrial applications.
Frame size affects:
The Frame 8 arrangement requires substantially more installation space than smaller PowerFlex 755 configurations.
For preliminary engineering and layout work, the following values can be used as approximate planning information.
| Mechanical Parameter | Approximate Value |
|---|---|
| Model | 20G1ALF500JN4NNNNN |
| Frame | Frame 8 |
| Height | Approx. 2453 mm |
| Width | Approx. 600 mm |
| Depth | Approx. 800 mm |
| Weight | Approx. 623 kg |
| Mechanical Style | MCC Style |
| Cooling | Forced Air |
| Enclosure | Type 1 / IP20 |
The 800 mm depth is associated with the specified MCC-style configuration.
The approximate 623 kg weight should be used only for preliminary planning. Actual equipment weight can vary with configuration, packaging and accessories.
Before lifting or transporting the drive, the actual shipping weight and lifting requirements should be confirmed.
The drive uses an 800 mm deep MCC-style mechanical arrangement.
This is an important consideration when planning an electrical room or MCC lineup.
The installation should allow for more than the physical cabinet depth.
Additional space may be required for:
The final equipment drawing should be used when designing the installation area.
The drive uses a forced-air cooling system.
At a 500 A rating, the drive can generate substantial heat during operation.
The installation therefore needs sufficient airflow.
Important factors include:
Insufficient cooling airflow can increase the internal operating temperature of the drive.
The specified Frame 8 MCC-style arrangement is associated with a Type 1 / IP20 enclosure class.
This type of equipment is intended for a suitable industrial electrical environment.
It should not be treated as a weatherproof or water-resistant outdoor enclosure.
Protection should be considered where the installation is exposed to:
A suitable electrical room or additional enclosure may be required depending on the installation environment.
The model uses an AC input with precharge and no DC terminals.
The precharge arrangement is part of the drive input architecture and manages the initial charging process of the internal DC bus.
The absence of DC terminals is important when designing the overall electrical system.
The drive should therefore be selected according to its specified AC input architecture rather than assuming it can be connected as a conventional common-DC-bus unit.
The drive is specified as a filtered configuration.
Filtering is useful in installations where conducted electrical noise and electromagnetic compatibility need to be controlled.
The complete installation should still consider:
Proper installation remains important even when the drive includes filtering.
The JN4 portion of the catalog number identifies a particular configuration within the PowerFlex 755 ordering structure.
The JN4 version should not be treated as electrically identical in every accessory detail to JN0 or JN2 versions simply because the basic drive rating is the same.
For purchasing and replacement work, the complete catalog number should be retained:
20G1ALF500JN4NNNNN
The complete ordering code should be checked against the final equipment label and purchase documentation before replacing a unit.
The drive includes embedded EtherNet/IP communication.
This provides a direct connection between the drive and an industrial automation network.
Typical control information can include:
Typical feedback can include:
This communication capability is useful in large industrial plants where drives are controlled and monitored from a centralized automation system.
A typical system can be arranged as:
Industrial Controller → EtherNet/IP Network → PowerFlex 755 → AC Motor
The controller can send operating commands to the drive.
The drive can return operating and diagnostic information.
This arrangement can reduce the amount of individual hardwired control wiring required for a large motor installation.
The 20G1ALF500JN4NNNNN can be considered for a wide range of high-power motor applications.
Typical applications include:
Large pumps are a common application for high-power variable-frequency drives.
Possible applications include:
Variable-speed operation allows the motor speed to be adjusted according to process requirements.
The drive can therefore be integrated with pressure, flow or process-control systems.
Large industrial fans can benefit from adjustable motor speed.
Potential applications include:
The drive allows fan speed to be adjusted instead of requiring the motor to operate continuously at one fixed speed.
Large blowers can require substantial motor power.
Potential applications include:
The drive provides adjustable speed and controlled acceleration for these applications.
Large conveyors are another important application area.
Potential equipment includes:
Variable-speed control can help coordinate material flow between different sections of the process.
The 690 V, 500 A rating is suitable for consideration in large mining motor systems.
Potential applications include:
Mining environments require additional attention to dust, vibration, temperature and equipment access.
Large cement and aggregate plants use many high-power motors.
The drive can be considered for:
Adjustable motor speed can be used to match production requirements.
Large AC motors are commonly used in metal-processing equipment.
Potential applications include:
The 690 V voltage class is suitable for many large-motor distribution systems.
The drive can be applied to large water and wastewater equipment.
Typical equipment includes:
Network communication can be used to monitor drive status and process information from a centralized control system.
Large compressors can also use high-power variable-frequency drives.
Potential applications include:
The drive can provide controlled acceleration and adjustable motor speed.
Compressor applications should be evaluated according to compressor type, torque curve, pressure requirement and required speed range.
The 500 A current rating allows the drive to control large industrial motors.
This provides substantially more current capacity than smaller PowerFlex 755 models.
The 530 kW LD, 500 kW ND and 400 kW HD ratings provide different application-duty references.
This allows the same drive platform to be considered for different load characteristics.
The 690 VAC voltage class is suitable for high-power motor systems.
For a given power level, higher motor voltage can reduce operating current compared with a lower-voltage motor system.
The built-in communication capability supports integration into an industrial automation network.
Drive commands and operating information can be exchanged through the network.
Frame 8 provides a mechanical platform suitable for high-power drive applications.
The larger construction accommodates the power components and cooling system required for a 500 A drive.
Forced-air cooling provides continuous heat removal from the high-power drive.
This is important when the drive is operating at high current for extended periods.
The filtered configuration supports installations where electrical noise and electromagnetic compatibility need to be considered.
The 800 mm deep MCC-style arrangement is suitable for integration into large industrial electrical installations.
It is particularly relevant where several high-power motor feeders are installed together.
The AC input with precharge provides a defined input configuration for the high-power drive.
This is important when designing the incoming electrical system.
The 20G1ALF500JN4NNNNN should be treated as heavy industrial electrical equipment.
| Installation Item | Recommended Planning Consideration |
|---|---|
| Model | 20G1ALF500JN4NNNNN |
| Supply Voltage | 690 VAC |
| Supply Phase | 3 Phase |
| Drive Current | 500 A |
| Frame | Frame 8 |
| Height | Approx. 2453 mm |
| Width | Approx. 600 mm |
| Depth | Approx. 800 mm |
| Weight | Approx. 623 kg |
| Cooling | Forced Air |
| Enclosure | Type 1 / IP20 |
| Installation Style | MCC / Floor-standing |
| Floor Loading | Verify before installation |
| Cable Entry | Provide adequate bending space |
| Ventilation | Provide sufficient airflow |
| Maintenance | Provide suitable service clearance |
| Lifting | Use suitable lifting equipment |
| Transportation | Confirm route and access |
| Communication | Plan EtherNet/IP network connection |
A drive with an approximate equipment weight of 623 kg requires proper floor-loading evaluation.
The installation should consider:
The actual packaged shipping weight can be greater than the bare equipment weight, so transportation planning should use the final shipping documentation.
The drive’s cooling system should have adequate access to clean cooling air.
The following conditions should be avoided:
Regular inspection of the cooling system is important for high-power equipment.
The motor cable should be selected according to the actual motor current and installation conditions.
Important factors include:
Long motor cables should be evaluated carefully because high-power variable-frequency systems can experience additional electrical effects associated with cable capacitance and reflected voltage.
The upstream electrical system should be designed specifically for the drive installation.
Important items include:
The final protection system must be selected according to the actual plant electrical system and applicable requirements.
Correct grounding is essential for high-power drive installations.
The system should provide appropriate arrangements for:
Good grounding also supports the overall electromagnetic compatibility of the installation.
The Type 1 / IP20 configuration is intended for an appropriate industrial electrical environment.
The installation should be evaluated for:
If the environment is unsuitable for IP20 equipment, an appropriate additional enclosure or controlled electrical room may be necessary.
Routine maintenance should focus on cooling, electrical connections and operating condition.
Typical inspection activities include:
Maintenance intervals should be based on actual operating conditions.
The following five models are useful comparison models within the same PowerFlex 755 high-power family.
They are presented as technical alternatives and reference models rather than as a ranking.
| Model | Voltage | Current | LD Rating | ND Rating | HD Rating | Frame | Cooling |
|---|---|---|---|---|---|---|---|
| 20G1ALF330JN4NNNNN | 690 VAC | 330 A | 355 kW | 315 kW | 250 kW | Frame 8 | Air Cooled |
| 20G1ALF370JN4NNNNN | 690 VAC | 370 A | 400 kW | 355 kW | 300 kW | Frame 8 | Air Cooled |
| 20G1ALF415JN4NNNNN | 690 VAC | 415 A | 450 kW | 400 kW | 355 kW | Frame 8 | Air Cooled |
| 20G1ALF460JN4NNNNN | 690 VAC | 460 A | 500 kW | 450 kW | 375 kW | Frame 8 | Air Cooled |
| 20G1ALF510JN4NNNNN | 690 VAC | 510 A | 550 HP | 500 HP | 450 HP | Frame 8 | Air Cooled |
The 330 A, 370 A, 415 A and 460 A configurations provide progressively lower current ratings, while the 510 A configuration provides a nearby higher-current reference.
| Model | Voltage | Current | LD | ND | HD | Frame | Depth |
|---|---|---|---|---|---|---|---|
| 20G1ALF330JN4NNNNN | 690 VAC | 330 A | 355 kW | 315 kW | 250 kW | Frame 8 | 800 mm |
| 20G1ALF370JN4NNNNN | 690 VAC | 370 A | 400 kW | 355 kW | 300 kW | Frame 8 | 800 mm |
| 20G1ALF415JN4NNNNN | 690 VAC | 415 A | 450 kW | 400 kW | 355 kW | Frame 8 | 800 mm |
| 20G1ALF460JN4NNNNN | 690 VAC | 460 A | 500 kW | 450 kW | 375 kW | Frame 8 | 800 mm |
| 20G1ALF500JN4NNNNN | 690 VAC | 500 A | 530 kW | 500 kW | 400 kW | Frame 8 | 800 mm |
These models are useful when sizing a drive according to motor current and required duty class.
| Model | Frame | Approx. Height | Approx. Width | Approx. Depth | Approx. Weight |
|---|---|---|---|---|---|
| 20G1ALF330JN4NNNNN | Frame 8 | Approx. 2453 mm | Approx. 600 mm | Approx. 800 mm | Approx. 623 kg* |
| 20G1ALF370JN4NNNNN | Frame 8 | Approx. 2453 mm | Approx. 600 mm | Approx. 800 mm | Approx. 623 kg* |
| 20G1ALF415JN4NNNNN | Frame 8 | Approx. 2453 mm | Approx. 600 mm | Approx. 800 mm | Approx. 623 kg* |
| 20G1ALF460JN4NNNNN | Frame 8 | Approx. 2453 mm | Approx. 600 mm | Approx. 800 mm | Approx. 623 kg* |
| 20G1ALF500JN4NNNNN | Frame 8 | Approx. 2453 mm | Approx. 600 mm | Approx. 800 mm | Approx. 623 kg* |
*Approximate planning values based on the general Frame 8 MCC-style arrangement. Individual mechanical drawings should be used for final engineering.
For a broader comparison within the same brand and PowerFlex 755 family, the following 480 VAC models can be used as reference points.
| Model | Voltage | Current | ND Rating | HD Rating | Frame | Cooling |
|---|---|---|---|---|---|---|
| 20G1AND125AN0NNNNN | 480 VAC | 125 A | 100 HP | 75 HP | Frame 6 | Air Cooled |
| 20G1AND156AN0NNNNN | 480 VAC | 156 A | 125 HP | 100 HP | Frame 6 | Air Cooled |
| 20G1AND186AN0NNNNN | 480 VAC | 186 A | 150 HP | 125 HP | Frame 6 | Air Cooled |
| 20G1AND248AN0NNNNN | 480 VAC | 248 A | 200 HP | 150 HP | Frame 6 | Air Cooled |
| 20G1AND302AN0NNNNN | 480 VAC | 302 A | 250 HP | 200 HP | Frame 7 | Air Cooled |
These models are useful for comparison when the motor system uses 480 VAC rather than the 690 VAC supply associated with the 20G1ALF500JN4NNNNN.
| Parameter | 20G1AND125AN0NNNNN | 20G1AND156AN0NNNNN | 20G1AND186AN0NNNNN | 20G1AND248AN0NNNNN | 20G1AND302AN0NNNNN |
|---|---|---|---|---|---|
| Voltage | 480 VAC | 480 VAC | 480 VAC | 480 VAC | 480 VAC |
| Current | 125 A | 156 A | 186 A | 248 A | 302 A |
| ND | 100 HP | 125 HP | 150 HP | 200 HP | 250 HP |
| HD | 75 HP | 100 HP | 125 HP | 150 HP | 200 HP |
| Frame | Frame 6 | Frame 6 | Frame 6 | Frame 6 | Frame 7 |
| Cooling | Air Cooled | Air Cooled | Air Cooled | Air Cooled | Air Cooled |
| Product Family | PowerFlex 755 | PowerFlex 755 | PowerFlex 755 | PowerFlex 755 | PowerFlex 755 |
The 480 V reference models use different frame sizes from the 690 V Frame 8 model.
For that reason, their dimensions and weights should not be assumed to be the same.
| Model | Frame | Approx. Height | Approx. Width | Approx. Depth | Approx. Weight |
|---|---|---|---|---|---|
| 20G1AND125AN0NNNNN | Frame 6 | Model-specific | Model-specific | Model-specific | Model-specific |
| 20G1AND156AN0NNNNN | Frame 6 | Model-specific | Model-specific | Model-specific | Model-specific |
| 20G1AND186AN0NNNNN | Frame 6 | Model-specific | Model-specific | Model-specific | Model-specific |
| 20G1AND248AN0NNNNN | Frame 6 | Model-specific | Model-specific | Model-specific | Model-specific |
| 20G1AND302AN0NNNNN | Frame 7 | Model-specific | Model-specific | Model-specific | Model-specific |
For engineering work, the exact mechanical drawing for each reference model should be used.
The 460 A model is a close electrical comparison.
| Parameter | 20G1ALF460JN4NNNNN | 20G1ALF500JN4NNNNN |
|---|---|---|
| Voltage | 690 VAC | 690 VAC |
| Current | 460 A | 500 A |
| LD Rating | 500 kW | 530 kW |
| ND Rating | 450 kW | 500 kW |
| HD Rating | 375 kW | 400 kW |
| Frame | Frame 8 | Frame 8 |
| Cooling | Air Cooled | Air Cooled |
| Depth | 800 mm | 800 mm |
| Communication | Embedded EtherNet/IP | Embedded EtherNet/IP |
| Input | AC with Precharge | AC with Precharge |
| DC Terminals | None | None |
| Filtering | Filtered | Filtered |
The 500 A model provides additional current capacity and higher published power ratings.
| Parameter | 20G1ALF415JN4NNNNN | 20G1ALF500JN4NNNNN |
|---|---|---|
| Voltage | 690 VAC | 690 VAC |
| Current | 415 A | 500 A |
| LD Rating | 450 kW | 530 kW |
| ND Rating | 400 kW | 500 kW |
| HD Rating | 355 kW | 400 kW |
| Frame | Frame 8 | Frame 8 |
| Cooling | Air Cooled | Air Cooled |
| Depth | 800 mm | 800 mm |
| Communication | Embedded EtherNet/IP | Embedded EtherNet/IP |
| Input | AC with Precharge | AC with Precharge |
| Filtering | Filtered | Filtered |
This comparison is useful when the motor current falls between the 415 A and 500 A ranges.
| Parameter | 20G1ALF370JN4NNNNN | 20G1ALF500JN4NNNNN |
|---|---|---|
| Voltage | 690 VAC | 690 VAC |
| Current | 370 A | 500 A |
| LD Rating | 400 kW | 530 kW |
| ND Rating | 355 kW | 500 kW |
| HD Rating | 300 kW | 400 kW |
| Frame | Frame 8 | Frame 8 |
| Cooling | Air Cooled | Air Cooled |
| Depth | 800 mm | 800 mm |
| Communication | Embedded EtherNet/IP | Embedded EtherNet/IP |
The 370 A version provides a lower-current alternative within the same general high-power family.
For large pump systems, the drive provides adjustable motor speed.
Potential advantages include:
The actual energy performance depends on the pump curve and operating conditions.
Large fans often do not require maximum speed continuously.
Variable-speed operation allows the motor to operate according to actual process demand.
Potential advantages include:
The drive can provide controlled acceleration and adjustable running speed for large conveyors.
This can help coordinate conveyor operation with:
The correct acceleration profile should be established from the conveyor mechanical characteristics.
Large process equipment often requires adjustable motor speed.
The drive can be used to regulate:
The drive’s network capability also allows operating information to be incorporated into the plant control system.
The embedded network interface can provide useful operating information for maintenance.
Typical diagnostic information can help identify:
This can reduce the time required to identify the general operating condition of the motor drive.
| Selection Item | Requirement |
|---|---|
| Model | 20G1ALF500JN4NNNNN |
| Brand | Allen-Bradley |
| Series | PowerFlex 755 |
| Supply Voltage | 690 VAC |
| Supply Phase | 3 Phase |
| Current | 500 A |
| LD Rating | 530 kW |
| ND Rating | 500 kW |
| HD Rating | 400 kW |
| Frame | Frame 8 |
| Cooling | Forced Air |
| Input | AC with Precharge |
| DC Terminals | None |
| Communication | Embedded EtherNet/IP |
| Filtering | Filtered |
| Mechanical Depth | 800 mm |
| Enclosure | Type 1 / IP20 |
| Height | Approx. 2453 mm* |
| Width | Approx. 600 mm* |
| Weight | Approx. 623 kg* |
| Dynamic Braking | Verify complete configuration |
| HIM | Verify complete JN4 configuration |
| Motor Current | Confirm before selection |
| Duty | Confirm LD/ND/HD requirement |
| Environment | Confirm before installation |
| Floor Loading | Verify before installation |
| Cable System | Verify before installation |
*Approximate planning values.
| Item | Specification |
|---|---|
| Model | 20G1ALF500JN4NNNNN |
| Brand | Allen-Bradley |
| Series | PowerFlex 755 |
| Product Type | High-Power AC Variable-Frequency Drive |
| Voltage | 690 VAC |
| Phase | 3 Phase |
| Current | 500 A |
| LD Rating | 530 kW |
| ND Rating | 500 kW |
| HD Rating | 400 kW |
| Frame | Frame 8 |
| Cooling | Air Cooled |
| Communication | Embedded EtherNet/IP |
| Input | AC Input with Precharge |
| DC Terminals | None |
| Filter | Filtered |
| Mechanical Style | MCC Style |
| Depth | 800 mm |
| Enclosure | Type 1 / IP20 |
| Approx. Height | 2453 mm* |
| Approx. Width | 600 mm* |
| Approx. Weight | 623 kg* |
| Typical Applications | Pumps, fans, blowers, conveyors, compressors, mining, cement, water and process equipment |
| Specification | 20G1ALF500JN4NNNNN |
|---|---|
| Brand | Allen-Bradley |
| Series | PowerFlex 755 |
| Product Category | AC Variable-Frequency Drive |
| Product Type | High-Power Industrial AC Drive |
| Input Voltage | 690 VAC |
| Input Phase | 3 Phase |
| Rated Current | 500 A |
| Light-Duty Rating | 530 kW |
| Normal-Duty Rating | 500 kW |
| Heavy-Duty Rating | 400 kW |
| Frame | Frame 8 |
| Cooling | Forced Air / Air Cooled |
| Input Configuration | AC Input with Precharge |
| DC Terminals | None |
| Filter | Filtered |
| Communication | Embedded EtherNet/IP |
| Mechanical Style | MCC Style |
| Depth | 800 mm |
| Enclosure | Type 1 / IP20 |
| Approx. Height | 2453 mm* |
| Approx. Width | 600 mm* |
| Approx. Depth | 800 mm |
| Approx. Weight | 623 kg* |
| Typical Motor Application | Large AC Motors |
| Typical Loads | Pumps, fans, blowers, conveyors, compressors and process machinery |
| Typical Industries | Mining, cement, aggregate, water, wastewater, manufacturing and process industries |
| Control | Variable-Speed AC Motor Control |
| Network | EtherNet/IP |
| Installation | Industrial electrical room, MCC or suitable cabinet arrangement |
*Approximate planning values. Final mechanical dimensions and weight should be confirmed from the exact supplied configuration.
The Allen-Bradley 20G1ALF500JN4NNNNN is a high-power PowerFlex 755 AC variable-frequency drive designed for large three-phase motor applications.
The combination of 690 VAC input, 500 A current capacity and 530/500/400 kW LD/ND/HD ratings makes this configuration suitable for large industrial motor systems.
The Frame 8 air-cooled construction provides the physical and thermal platform required for a high-power drive of this size.
The 800 mm MCC-style depth should be taken into account when planning electrical rooms, MCC lineups, cable routing, maintenance access and transportation.
The embedded EtherNet/IP interface allows the drive to operate as part of a networked automation system. Commands, operating values, status information and diagnostic information can be exchanged between the drive and the control system.
The drive’s AC input with precharge and no DC terminals defines its basic incoming power arrangement. The filtered configuration and JN4 ordering configuration should also be retained when specifying a replacement or preparing a quotation.
The drive can be used for large pumps, fans, blowers, conveyors, compressors, mining equipment, cement machinery, water systems, wastewater equipment, material-handling systems and other large industrial motor loads.
The approximate mechanical planning values of 2453 mm height, 600 mm width, 800 mm depth and 623 kg weight are useful for preliminary layout and equipment planning. They should not be used as a replacement for the final mechanical drawing when fabricating a cabinet, calculating floor loading, arranging lifting equipment or preparing transportation.
For final selection, the most important checks are motor full-load current, required duty class, supply voltage, load torque, acceleration and deceleration requirements, braking requirements, environmental conditions, cooling, cable installation, upstream protection and available installation space.
The 20G1ALF500JN4NNNNN is therefore a high-power industrial drive configuration intended for large 690 V AC motors where adjustable speed, controlled motor operation and network-based automation are required.