The Schneider STBDDO3600K Modicon STB Standard Digital Output Kit is a packaged digital output solution for Modicon STB distributed I/O systems. It combines the required output module and associated STB hardware for installation as part of a distributed I/O island.
The kit is used to interface controller-generated digital commands with discrete field devices such as relays, contactors, solenoid valves, indicators, and other on/off actuators. The controller determines the required output state, while the STB island transfers that command to the digital output hardware.
The kit format is useful when installing or replacing a complete STB output position rather than sourcing the module alone. Compatibility with the network interface, terminal base, power distribution, and overall STB island configuration should still be checked before installation.
| Parameter | Specification |
|---|---|
| Product Model | STBDDO3600K |
| Product Family | Modicon STB |
| Product Type | Standard Digital Output Kit |
| I/O Type | Digital Output |
| Application | Discrete field-device control |
| Installation | Modicon STB distributed I/O island |
| Dimensions | 128.3 × 13.9 × 70 mm |
| Weight | 0.114 kg |
The STBDDO3600K operates as part of the Modicon STB distributed I/O architecture. The controller generates an output command according to the application program, and the STB network interface transfers that command to the appropriate output position.
The digital output hardware then switches the corresponding field circuit according to the commanded state. This allows the control system to operate discrete devices such as solenoid valves, contactors, relays, and indicators.
Because the product is supplied as a kit, installation involves more than simply replacing an electronic module. The associated terminal connection, island position, field wiring, power arrangement, and I/O configuration must all correspond to the existing STB system.
| System Element | Function |
|---|---|
| PLC / Controller | Executes application logic and determines output states |
| STB Network Interface Module | Connects the STB island to the controller or fieldbus network |
| STBDDO3600K | Provides the packaged digital output interface for discrete field control |
| STB Terminal Base | Provides the physical electrical connection for the output position |
| Field Power Supply | Supplies power to connected output loads |
| Actuators | Respond to digital commands from the control system |
| Sensors / Input Modules | Return process and equipment status to the controller |
| HMI / SCADA | Provides operator monitoring, alarms, and commands |
The STBDDO3600K occupies the output interface layer of the STB architecture. The controller remains responsible for application logic, while the kit provides the hardware required to deliver discrete commands to the field.
| Application | Typical Use |
|---|---|
| Machine Automation | Operating relays, contactors, solenoid valves, and machine actuators |
| Packaging Equipment | Controlling pneumatic devices, indicators, and auxiliary mechanisms |
| Material Handling | Switching conveyor-related actuators and status devices |
| Process Automation | Discrete control of valves, alarms, and auxiliary equipment |
| Water and Wastewater | Controlling pumps, valves, and discrete field devices |
| General Industrial Automation | Replacement or installation of complete STB digital output positions |
| Component | Function |
|---|---|
| Modicon STB Network Interface Module | Connects the STB island to the control network |
| STB Terminal Base | Provides the physical connection for the I/O position |
| STB Power Distribution Components | Distribute logic and field power within the island |
| STB Digital Input Modules | Acquire discrete signals from field devices |
| STB Analog I/O Modules | Interface variable process signals |
| PLC / Controller | Executes application logic |
| Contactors and Relays | Switch compatible field loads |
| Solenoid Valves | Convert digital electrical commands into mechanical actions |
| Model / Product Family | Product Type | Typical Application |
|---|---|---|
| Schneider STBDDO3600 | Modicon STB Standard Digital Output Module | Discrete field output control |
| Schneider STBDDO3410 | Modicon STB Standard Digital Output Module | Standard digital actuator control |
| Schneider STBDDI3610 | Modicon STB Standard Digital Input Module | Discrete field signal acquisition |
| Schneider STBDDI3610K | Modicon STB Standard Digital Input Kit | Packaged digital input installation |
| Schneider STBDDI3725 | Modicon STB Basic Digital Input Module | Basic discrete input applications |
| Schneider STBACO0220 | Modicon STB Standard Analog Output Module | Analog process and actuator outputs |
| Schneider STBAVI1255 | Modicon STB Basic Analog Input Module | Analog process signal acquisition |
STBDDO3600 is the Standard Digital Output Module, while STBDDO3600K is identified as the Standard Digital Output Kit. The kit format is intended for a more complete installation arrangement and should be matched to the required STB hardware configuration.
No. The kit provides the digital output hardware, but output decisions come from the PLC or controller through the Modicon STB network architecture.
Check the field-side power supply, terminal connections, wiring, protection devices, actuator condition, and load requirements. A correct controller command does not by itself confirm that the field device is receiving usable power.
The installation position must match the applicable STB system configuration and hardware arrangement. Verify the network interface, terminal base, adjacent modules, addressing, and power distribution before installation.