• GE IS200TBAIH1BBB Mark VI Analog Input Terminal Board
  • GE IS200TBAIH1BBB Mark VI Analog Input Terminal Board
  • GE IS200TBAIH1BBB Mark VI Analog Input Terminal Board
  • GE IS200TBAIH1BBB Mark VI Analog Input Terminal Board
Product Overview The GE IS200TBAIH1BBB is a Mark VI Analog Input Terminal Board used to interface analog field signals with the GE Mark VI turbine control system. It provides a physical termination poin……
GE IS200TBAIH1BBB Mark VI Analog Input Terminal Board
  • GE
  • IS200TBAIH1BBB
  • Analog Input Terminal Board
  • USA
  • 330.2 × 20 × 101.6 mm
  • 1.1 kg
  • Xiamen, China
  • New & In Stock
  • T/T, PayPal, Western Union
  • 1 Year
  • 1-3 Working Days
  • DHL, UPS, TNT, FedEx and EMS.
  • 24-Hour Service
  • COO
  • 21

Our advantage

GE IS200TBAIH1BBB Mark VI Analog Input Terminal Board

Global Logistics

We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.

GE IS200TBAIH1BBB Mark VI Analog Input Terminal Board

Brand new and original

Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.

GE IS200TBAIH1BBB Mark VI Analog Input Terminal Board

24-hour service

We provide 7*24 hours service to our customers. We will be there whenever you need us.

GE IS200TBAIH1BBB Mark VI Analog Input Terminal Board

Price advantage

All our products are priced very favorably because we have our own warehouse and supply.


Company Information
E-mail [email protected]
Mobile +8615980777398
Whatsapp +8615980777398
WeChat 15980777398

Product Overview

The GE IS200TBAIH1BBB is a Mark VI Analog Input Terminal Board used to interface analog field signals with the GE Mark VI turbine control system. It provides a physical termination point for incoming analog signals and organizes the connection between field instrumentation and the associated Mark VI I/O hardware.

In turbine applications, analog signals can represent operating parameters such as pressure, temperature, flow, level, or other continuously varying process measurements. The terminal board provides the field-side connection through which these signals enter the control architecture before being processed by the appropriate I/O and controller hardware.

The IS200TBAIH1BBB is therefore part of the signal interface layer rather than the main control processor. Its condition and wiring quality can directly affect the signals presented to the Mark VI control system, making correct terminal identification and field wiring inspection important during commissioning and maintenance.


Technical Specifications

Parameter Specification
Manufacturer GE
Model IS200TBAIH1BBB
Product Family Mark VI
Product Type Analog Input Terminal Board
Signal Type Analog Input
Primary Function Analog field signal termination and interface
Application Turbine control and process measurement
Installation Industrial turbine control cabinet
Dimensions 330.2 × 20 × 101.6 mm
Weight 1.1 kg

Product Features

  • Analog field signal termination for Mark VI systems
  • Provides an interface between field instrumentation and Mark VI I/O hardware
  • Suitable for continuously varying process measurements
  • Supports organized field wiring within turbine control cabinets
  • Helps separate field signal connections from controller-level processing
  • Suitable for turbine instrumentation and auxiliary process measurements
  • Accessible terminal arrangement for commissioning and maintenance

Working Principle

The IS200TBAIH1BBB provides the physical connection between analog field instruments and the Mark VI signal acquisition architecture.

A typical signal path is:

Analog Field Instrument → IS200TBAIH1BBB → Mark VI I/O Hardware → Mark VI Controller

The field instrument generates an analog electrical signal corresponding to the measured process variable. The terminal board provides the connection and routing point for that signal, while the associated Mark VI I/O hardware performs the actual signal acquisition and conversion required by the control system.

The terminal board itself does not execute turbine control logic. Its role is to maintain an organized and electrically appropriate interface between field wiring and the control-system I/O layer.


Role in a Mark VI Turbine Control Architecture

The IS200TBAIH1BBB belongs to the field termination and analog signal interface layer of a Mark VI control system. It allows analog instrumentation signals to enter the control architecture in an organized manner before they are processed by the associated I/O and controller hardware.

System Element Function
Analog Field Instruments Measure continuously varying turbine or process parameters
IS200TBAIH1BBB Terminal Board Terminates and interfaces incoming analog field signals
Mark VI I/O Hardware Acquires and processes the connected analog input signals
Mark VI Controller Executes control logic, sequencing, and supervisory functions
Engineering / Diagnostic System Supports configuration, monitoring, and troubleshooting
Turbine Auxiliary Equipment Generates or responds to the measured process conditions

Correct wiring at the terminal board is important because an open circuit, incorrect termination, or wiring fault can appear at the control level as an abnormal process measurement.


Industrial Applications

Application Typical Use
Gas Turbine Control Interfaces analog measurements used for turbine operation and monitoring
Steam Turbine Control Provides field termination for analog process and equipment measurements
Pressure Monitoring Connects pressure-related instrumentation to the Mark VI I/O architecture
Temperature Monitoring Interfaces temperature measurement circuits used by turbine control functions
Flow Measurement Provides a termination point for analog flow instrumentation
Generator Systems Supports analog measurements associated with turbine-generator equipment
Balance-of-Plant Equipment Interfaces selected continuous process measurements with the control system
Turbine Maintenance and Retrofit Provides field termination hardware for existing Mark VI analog input circuits

Installation and Maintenance

  1. Verify the Board Model — Confirm that the replacement board is IS200TBAIH1BBB and matches the intended Mark VI system configuration.
  2. Document Existing Wiring — Record terminal assignments, wire numbers, signal descriptions, and field device identification before removing an installed board.
  3. Isolate the Relevant Circuits — Follow approved control-system and electrical isolation procedures before working on field wiring.
  4. Check Signal Polarity and Termination — Verify each analog circuit against the applicable Mark VI wiring documentation before reconnecting the conductors.
  5. Inspect Terminal Connections — Check for loose conductors, damaged terminals, corrosion, or signs of overheating.
  6. Check Field Instrument Wiring — Inspect the cable route and field device connections when an analog signal appears unstable or incorrect.
  7. Verify Signal Continuity — Confirm continuity through the field circuit when an expected analog input is missing.
  8. Inspect Grounding and Shielding — Check the applicable signal grounding and shielding arrangement when analog readings show unexpected noise or fluctuation.
  9. Compare the Field Signal with the Controller Reading — When troubleshooting, compare the measured field signal with the value reported by the Mark VI system to help locate the fault.
  10. Check Associated I/O Hardware — If multiple analog channels are affected, inspect the associated I/O hardware and common connections rather than replacing the terminal board immediately.
  11. Perform Functional Testing — After replacement or rewiring, verify representative analog signals through the complete field-to-controller signal path.
  12. Follow Turbine Safety Procedures — Maintenance should comply with approved turbine shutdown, electrical isolation, lockout/tagout, and control-system procedures.

For troubleshooting, determine whether the problem originates in the field instrument, field wiring, terminal board, associated I/O hardware, or control configuration. A single abnormal channel often points toward a local circuit issue, while multiple affected channels can indicate a common interface or I/O problem.


Related Components

Component Function
Analog Field Transmitters Generate analog signals representing measured process variables
Mark VI I/O Hardware Acquires and processes analog input signals
Mark VI Controller Executes control logic based on acquired process information
Field Wiring Carries analog measurement signals between instruments and the terminal board
Signal Shielding / Grounding Hardware Helps maintain signal integrity where applicable
Engineering / Diagnostic System Supports configuration and signal troubleshooting
Turbine Auxiliary Equipment Provides the process conditions being measured

Recommended Related Models

Model / Product Family Product Type Typical Application
GE IS200TBAIH1BBB Mark VI Analog Input Terminal Board Analog field signal termination
GE Mark VI Turbine Control System Gas and steam turbine control
GE Mark VI Analog I/O Hardware Analog Input / Output Hardware Acquisition and processing of analog field signals
GE Mark VI Terminal Boards Field Interface Hardware Field wiring termination and signal distribution
GE Mark VI Control Processor Turbine Control Processor Control logic, sequencing, and system coordination

Key Advantages

  • Dedicated interface for analog field signals
  • Organizes analog instrumentation wiring within the Mark VI architecture
  • Supports turbine and process measurement applications
  • Provides accessible field termination points
  • Separates field connections from controller-level processing
  • Suitable for maintenance and replacement of existing Mark VI installations

Technical FAQs

What is the main function of the GE IS200TBAIH1BBB?

The IS200TBAIH1BBB is a Mark VI Analog Input Terminal Board. It provides the field-side termination and interface for analog signals before they are acquired by the associated Mark VI I/O hardware.

Does the IS200TBAIH1BBB convert analog signals into control decisions?

No. The terminal board provides the physical signal interface. Analog acquisition and processing are handled by the associated Mark VI I/O hardware, while control decisions are executed by the Mark VI controller.

What should be checked when an analog input shows an incorrect value?

Check the field instrument, wiring continuity, terminal assignment, polarity, grounding or shielding arrangement, and associated I/O channel. Comparing the actual field signal with the value reported by the Mark VI system can help identify where the signal path is being affected.

What should be verified when replacing the IS200TBAIH1BBB?

Verify the exact board model and system configuration, document all existing terminal assignments, isolate the relevant circuits, and reconnect the field wiring according to the applicable Mark VI documentation. Functional testing should confirm the complete analog signal path after replacement.



Related Products

Get the latest price? We will reply as soon as possible (within 12 hours)

No:77501