• GE SSF16G216 Power Break II Insulated Case Circuit Breaker
  • GE SSF16G216 Power Break II Insulated Case Circuit Breaker
  • GE SSF16G216 Power Break II Insulated Case Circuit Breaker
  • GE SSF16G216 Power Break II Insulated Case Circuit Breaker
Product Overview The GE SSF16G216 is a Power Break II Insulated Case Circuit Breaker used for protection and switching in industrial and commercial electrical distribution systems. It is intended for ap……
GE SSF16G216 Power Break II Insulated Case Circuit Breaker
  • GE
  • SSF16G216
  • Insulated Case Circuit Breaker
  • USA
  • 432.9 × 284.1 × 330.2 mm
  • 35.83 kg
  • Xiamen, China
  • New & In Stock
  • T/T, PayPal, Western Union
  • 1 Year
  • 1-3 Working Days
  • DHL, UPS, TNT, FedEx and EMS.
  • 24-Hour Service
  • COO
  • 42

Our advantage

GE SSF16G216 Power Break II Insulated Case Circuit Breaker

Global Logistics

We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.

GE SSF16G216 Power Break II Insulated Case Circuit Breaker

Brand new and original

Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.

GE SSF16G216 Power Break II Insulated Case Circuit Breaker

24-hour service

We provide 7*24 hours service to our customers. We will be there whenever you need us.

GE SSF16G216 Power Break II Insulated Case Circuit Breaker

Price advantage

All our products are priced very favorably because we have our own warehouse and supply.


Company Information
E-mail [email protected]
Mobile +8615980777398
Whatsapp +8615980777398
WeChat 15980777398

Product Overview

The GE SSF16G216 is a Power Break II Insulated Case Circuit Breaker used for protection and switching in industrial and commercial electrical distribution systems. It is intended for applications where large electrical loads require controlled interruption and overcurrent protection within a low-voltage distribution system.

As part of a distribution assembly, the circuit breaker monitors current flowing through the protected circuit and interrupts the circuit when a qualifying fault or overcurrent condition is detected. It can also be used for routine circuit switching and equipment isolation during maintenance.

The SSF16G216 is particularly relevant to switchgear, motor control, plant distribution, and other installations where feeder protection must be coordinated with upstream and downstream protective devices.


Technical Specifications

Parameter Specification
Manufacturer GE
Model SSF16G216
Product Family Power Break II
Product Type Insulated Case Circuit Breaker
Breaker Type Insulated Case Circuit Breaker
Application Low-Voltage Electrical Distribution
Protection Function Overcurrent and Short-Circuit Protection
Switching Function Circuit Switching and Isolation
Dimensions 432.9 × 284.1 × 330.2 mm
Weight 35.83 kg

Product Features

  • Power Break II insulated case circuit breaker construction.
  • Intended for industrial and commercial power distribution applications.
  • Provides circuit interruption during qualifying overcurrent and fault conditions.
  • Can serve as a feeder or equipment protection device.
  • Supports controlled switching and electrical isolation.
  • Suitable for integration into low-voltage switchgear and distribution assemblies.
  • Appropriate for plant electrical systems requiring coordinated circuit protection.

Working Principle

The SSF16G216 is installed in series with the circuit being protected. Under normal conditions, current passes through the breaker to supply the connected load.

A simplified protection path is:

Power Source → SSF16G216 Circuit Breaker → Distribution Circuit → Electrical Load

The breaker monitors the electrical conditions of the protected circuit. When an overcurrent or short-circuit condition reaches the applicable trip threshold, the breaker mechanism opens the circuit and interrupts current flow.

Once the circuit has been isolated, maintenance personnel can investigate the fault before restoring power. In normal operation, the breaker can also be operated as a switching and isolation device according to the requirements of the installation.


Role in a Power Distribution Architecture

The SSF16G216 sits between the electrical source and the downstream distribution or load circuit.

System Element Function
Incoming Power Source Supplies electrical power to the distribution system
Main Distribution Equipment Routes power to individual feeders
SSF16G216 Circuit Breaker Provides overcurrent protection and circuit interruption
Downstream Feeder Carries protected power to the load or sub-distribution equipment
Electrical Load Consumes the supplied electrical power
Protective Coordination System Coordinates breaker operation with other protective devices

Correct application requires consideration of the complete distribution system, including available fault current, conductor ratings, downstream equipment, and coordination with other protective devices.


Industrial Applications

Application Typical Use
Industrial Power Distribution Feeder and equipment circuit protection
Manufacturing Plants Protection of production equipment power circuits
Motor Control Systems Protection of motor-related distribution circuits
Switchgear Assemblies Main or feeder circuit interruption
Commercial Facilities Protection of building distribution circuits
Process Plants Protection of electrical feeders supplying process equipment
Maintenance Power Isolation Controlled interruption of electrical circuits

Installation and Maintenance

  1. Verify the SSF16G216 model and breaker configuration against the electrical system design before installation.
  2. Confirm that the breaker is suitable for the system voltage, current, fault level, and application.
  3. Follow the applicable electrical safety procedures and fully isolate the circuit before installation or maintenance.
  4. Verify that upstream and downstream protective devices are properly coordinated.
  5. Check busbar, cable, and terminal connections for correct installation and secure contact.
  6. Inspect the breaker housing and operating mechanism for visible damage before energization.
  7. Confirm that the breaker operates correctly through its intended manual or control mechanism.
  8. Check trip and protection functions according to the maintenance procedure specified for the installation.
  9. Inspect electrical connections periodically for signs of overheating, looseness, or deterioration.
  10. Investigate the cause of every protective trip before resetting the breaker.
  11. Keep maintenance records for breaker operation, inspections, testing, and fault events.
  12. After maintenance, verify correct circuit operation and protective-device status before returning the equipment to service.

Related Components

Component Function
Power Break II Accessories Provide compatible breaker control, indication, and installation functions
Busbar System Provides electrical connection to the distribution assembly
Feeder Conductors Carry protected power to downstream equipment
Protective Relays Provide additional monitoring or protection functions where required
Auxiliary Contacts Provide breaker status information to control or monitoring systems
Trip Accessories Support remote or electrically controlled breaker operation where configured
Switchgear Assembly Houses and integrates the circuit breaker within the distribution system

Recommended Related Models

Model Product Type Typical Relationship
GE Power Break II Circuit Breakers Insulated Case Circuit Breaker Same product family for related protection applications
GE Power Break II Accessories Circuit Breaker Accessories Supports breaker control, indication, and integration
GE Feeder Protection Components Protection Equipment Related equipment for coordinated feeder protection
GE Switchgear Components Distribution Equipment Supports integration into electrical distribution assemblies
GE Motor Protection Components Motor Protection Equipment Related protection hardware for motor-driven loads

Key Advantages

  • Provides circuit interruption for qualifying overcurrent and fault conditions.
  • Suitable for industrial and commercial low-voltage distribution.
  • Supports feeder and equipment protection.
  • Can be integrated into switchgear and distribution assemblies.
  • Provides a means of controlled circuit switching and isolation.
  • Part of the Power Break II circuit protection platform.

Technical FAQs

What is the primary function of the GE SSF16G216?

The SSF16G216 is an insulated case circuit breaker used to protect and switch electrical distribution circuits. Its protection function interrupts the circuit when an applicable overcurrent or fault condition is detected.

Where is the SSF16G216 typically installed?

It can be used in low-voltage distribution equipment such as industrial switchgear, feeder assemblies, motor-related distribution systems, and plant electrical distribution panels.

What should be checked before replacing an SSF16G216?

The breaker configuration, system voltage, continuous current requirements, available fault current, conductor ratings, protection settings, and coordination with upstream and downstream protective devices should be verified before replacement.

What should be investigated after the breaker trips?

Do not simply reset the breaker without identifying the cause. Check the downstream circuit and connected equipment for overloads, short circuits, insulation problems, or other abnormal conditions before restoring power.



Related Products

Get the latest price? We will reply as soon as possible (within 12 hours)

No:77501