• Schneider STBACI1230 Modicon STB Standard Analog Input Module
  • Schneider STBACI1230 Modicon STB Standard Analog Input Module
  • Schneider STBACI1230 Modicon STB Standard Analog Input Module
  • Schneider STBACI1230 Modicon STB Standard Analog Input Module
Product Overview The Schneider STBACI1230 Modicon STB Standard Analog Input Module is an analog signal acquisition module for the Modicon STB distributed I/O platform. It brings continuous electrical si……
Schneider STBACI1230 Modicon STB Standard Analog Input Module
  • Schneider
  • STBACI1230
  • Standard Analog Input Module
  • France
  • 70 × 18.4 × 128.3 mm
  • 0.116 kg
  • Xiamen, China
  • New & In Stock
  • T/T, PayPal, Western Union
  • 1 Year
  • 1-3 Working Days
  • DHL, UPS, TNT, FedEx and EMS.
  • 24-Hour Service
  • COO
  • 5

Our advantage

Schneider STBACI1230 Modicon STB Standard Analog Input Module

Global Logistics

We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.

Schneider STBACI1230 Modicon STB Standard Analog Input Module

Brand new and original

Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.

Schneider STBACI1230 Modicon STB Standard Analog Input Module

24-hour service

We provide 7*24 hours service to our customers. We will be there whenever you need us.

Schneider STBACI1230 Modicon STB Standard Analog Input Module

Price advantage

All our products are priced very favorably because we have our own warehouse and supply.


Company Information
E-mail [email protected]
Mobile +8615980777398
Whatsapp +8615980777398
WeChat 15980777398

Product Overview

The Schneider STBACI1230 Modicon STB Standard Analog Input Module is an analog signal acquisition module for the Modicon STB distributed I/O platform. It brings continuous electrical signals from compatible field instruments into the distributed I/O island so that process measurements can be exchanged with the higher-level controller.

The module fits applications where instrumentation is distributed around a machine, production line, or process installation. Field transmitters can be connected at the local STB I/O station while the controller remains in a separate control cabinet or automation station.

Typical measurement tasks include monitoring process variables such as temperature, pressure, level, flow, and other continuously changing signals supported by the installed instrumentation. The STBACI1230 handles the input-side acquisition, while the PLC or controller uses the resulting process values for regulation, sequencing, alarms, and supervisory functions.

For commissioning, the module also provides a practical point for checking the complete analog signal path. If a displayed process value is incorrect, technicians can compare the field instrument signal, wiring, input channel, STB communication, and controller scaling to locate the source of the discrepancy.


Technical Specifications

Parameter Specification
Manufacturer Schneider Electric
Model STBACI1230
Product Family Modicon STB
Product Type Standard Analog Input Module
Primary Function Analog field signal acquisition
System Role Distributed analog input interface
Application Machine and process automation
Dimensions 70 × 18.4 × 128.3 mm
Weight 0.116 kg

Product Features

  • Modicon STB Standard Analog Input Module
  • Provides analog signal acquisition within an STB distributed I/O island
  • Suitable for continuous process-variable monitoring
  • Connects compatible field instrumentation to the distributed control architecture
  • Supports local acquisition of analog process signals
  • Suitable for machine and process automation systems
  • Integrates with compatible STB network and power infrastructure
  • Useful for commissioning, diagnostics, and replacement applications

Working Principle

The STBACI1230 receives an analog signal from a connected field instrument and converts the measured input into data that can be processed through the Modicon STB I/O architecture.

Field Sensor / Transmitter → STBACI1230 → STB I/O Island → Network Interface → PLC / Controller

The field instrument produces a continuously varying electrical signal corresponding to the measured process condition. The module acquires this signal and makes the resulting input value available to the STB network interface for transfer to the controller.

The controller can then apply the value to process regulation, machine sequencing, alarm handling, trending, or operator visualization. The input module itself performs signal acquisition rather than deciding how the process should respond.

A fault anywhere in the measurement chain can affect the value seen by the controller. Field wiring, instrument condition, channel configuration, signal compatibility, grounding, and STB network communication should therefore be considered together when troubleshooting an abnormal reading.


Role in a Modicon STB Distributed I/O Control Architecture

The STBACI1230 occupies the analog signal acquisition layer of the Modicon STB distributed I/O architecture. It provides the local interface between analog field instrumentation and the networked control system.

Analog Instrument → STBACI1230 → STB I/O Island → Network Interface → PLC / Controller → HMI / SCADA

System Element Function
Analog Instrument Generates the process measurement signal
STBACI1230 Acquires the analog field signal
STB I/O Island Provides distributed I/O infrastructure
Network Interface Exchanges I/O data with the control network
PLC / Controller Processes measurements and executes control logic
HMI / SCADA Displays process values and operating information
Alarm / Control Functions Uses configured values for monitoring and process action

The distributed arrangement allows field measurements to be collected close to the instrument while the main controller remains responsible for application-level decisions.


Industrial Applications

Application Typical Use
Process Automation Acquisition of continuous process measurements
Temperature Monitoring Collection of compatible temperature signals
Pressure Monitoring Interface to pressure transmitters
Level Measurement Monitoring vessels, tanks, and process equipment
Flow Monitoring Acquisition of flow-related process values
Packaging Machinery Monitoring continuously varying machine signals
Manufacturing Systems Distributed analog measurement
Water and Utility Systems Remote process-variable acquisition
Machine Automation Monitoring analog operating conditions

Installation and Maintenance

  1. Verify that the STBACI1230 is compatible with the intended Modicon STB island configuration.
  2. Confirm the connected field instrument and its required analog signal arrangement before wiring.
  3. Isolate the relevant field circuit before installing or servicing the module.
  4. Check the STB island power and network infrastructure before commissioning.
  5. Verify the module position and channel assignment against the approved I/O documentation.
  6. Inspect field conductors and terminal connections for looseness, damage, or incorrect termination.
  7. Confirm that the connected sensor or transmitter produces the expected signal under known process conditions.
  8. Install and secure the module according to the applicable STB system arrangement.
  9. Verify the configured analog input and confirm that the controller recognizes the expected channel data.
  10. Compare the controller value with the field instrument or an approved reference during commissioning.
  11. If the input is unstable or inaccurate, check the instrument, wiring, configuration, grounding, and network communication separately.
  12. After replacement or maintenance, verify the complete analog signal path and confirm correct process values at the controller and HMI.

Compatible System Components

Component Function
Modicon STB Network Interface Connects the I/O island to the control network
Modicon STB Power Distribution Supplies the distributed I/O island
STB Terminal Base Provides module mounting and field-wiring interface
Analog Sensors / Transmitters Generate continuous measurement signals
STB Digital Input Modules Provides discrete field-status interfaces
STB Analog Output Modules Provides analog control outputs
PLC / Controller Processes input values and executes control logic
HMI / SCADA Displays measurements and diagnostic information
Field Wiring Carries analog signals between instruments and I/O

Recommended Related Models

Model / Product Family Product Type Typical Application
Schneider STBACI1230 Standard Analog Input Module Distributed analog signal acquisition
Schneider STBACI0320 Standard Analog Input Module Analog field signal acquisition
Schneider STBACI0320K Standard Analog Input Kit Packaged analog input installation
Schneider Modicon STB Distributed I/O Platform Machine and process automation
Schneider STB Analog Input Modules Analog Input Module Family Process-variable acquisition
Schneider STB Analog Output Modules Analog Output Module Family Analog actuator control
Schneider STB Digital Input Modules Digital Input Module Family Discrete field-status acquisition
Schneider STB Network Interface Modules Network Interface Module Distributed I/O communication

Key Advantages

  • Provides analog signal acquisition within the Modicon STB distributed I/O platform.
  • Supports local collection of process measurements from distributed instrumentation.
  • Allows analog field values to be transferred to the PLC through the STB network architecture.
  • Suitable for machine, process, manufacturing, and utility automation.
  • Keeps field-level measurement acquisition separate from controller application logic.
  • Supports structured commissioning and troubleshooting of analog measurement channels.

Technical FAQs

How does the STBACI1230 fit into a distributed I/O installation?

The module is installed within a compatible STB I/O island and connects analog field instrumentation to the island’s communication infrastructure. The network interface then exchanges the acquired data with the PLC or controller.

What should be checked if the field instrument is working but the PLC receives an incorrect value?

Compare the signal at the field instrument with the value acquired by the STBACI1230. Then check wiring, channel configuration, signal scaling, grounding, and communication between the STB island and controller.

What is the difference between an analog input module and an analog output module in the STB system?

An analog input module acquires continuously varying signals from field instruments, while an analog output module sends controller-generated analog commands toward compatible field equipment. They serve opposite directions within the control signal path.

When is replacement of the STBACI1230 likely to be necessary?

Replacement may be considered when the module fails to acquire the expected input despite verified field wiring, instrumentation, configuration, and STB communication. Before replacing it, the complete signal path should be checked to avoid treating a wiring or configuration problem as an I/O hardware failure.



Related Products

Get the latest price? We will reply as soon as possible (within 12 hours)

No:77501