Our advantage
Global Logistics
We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.
Brand new and original
Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.
24-hour service
We provide 7*24 hours service to our customers. We will be there whenever you need us.
Price advantage
All our products are priced very favorably because we have our own warehouse and supply.
| Company Information | |||
| [email protected] | |||
| Mobile | +8615980777398 | ||
| +8615980777398 | |||
| 15980777398 |

The Schneider TSXCPP110 Modicon Premium CANopen Bus Master PCMCIA Card is a communication interface used to connect a Modicon Premium automation controller to CANopen field devices. It provides the controller with access to a CANopen network, allowing distributed devices to exchange process and diagnostic information with the Premium control system.
The card is suited to control architectures where sensors, actuators, drives, distributed I/O, and other CANopen-compatible equipment are located away from the main controller. By placing the CANopen master function at the controller communication layer, the Premium PLC can coordinate multiple field devices through a common network.
A typical installation uses the TSXCPP110 as the communication bridge between the Premium processor and a CANopen device network. The PLC application determines the required machine sequence, while the communication card handles the exchange of configured network data with connected CANopen nodes.
For commissioning and troubleshooting, communication status can be evaluated separately from the PLC application logic and individual field devices. This makes it possible to determine whether a problem originates from the controller configuration, CANopen network, node addressing, wiring, or a connected device.
| Parameter | Specification |
|---|---|
| Manufacturer | Schneider Electric |
| Model | TSXCPP110 |
| Product Family | Modicon Premium |
| Product Type | CANopen Bus Master PCMCIA Card |
| Primary Function | CANopen master communication |
| System Role | PLC fieldbus communication interface |
| Application | CANopen device networking and industrial automation |
| Dimensions | 110 × 35 × 80 mm |
| Weight | 0.23 kg |
The TSXCPP110 operates as the CANopen master interface within a compatible Modicon Premium control system. The Premium controller exchanges configured process data through the card with devices connected to the CANopen network.
The controller application determines which data must be read or written. The TSXCPP110 manages the corresponding CANopen communication exchange, allowing connected nodes to provide input information or receive commands from the control system.
Modicon Premium Controller → TSXCPP110 CANopen Master → CANopen Network → Distributed Field Devices
Input information from CANopen nodes can be made available to the PLC application for sequencing, monitoring, interlocking, or diagnostic purposes. Output information generated by the controller can travel in the opposite direction to compatible networked devices.
The card therefore handles communication rather than the physical control action itself. A network communication fault can prevent valid controller commands or device feedback from reaching their intended destinations even when the PLC application is functioning correctly.
The TSXCPP110 occupies the fieldbus communication layer between the Premium controller and CANopen devices. It allows distributed equipment to participate in the controller’s automation system without requiring every field signal to be wired directly to local PLC I/O.
Premium PLC → TSXCPP110 → CANopen Bus → CANopen Nodes → Drives / I/O / Sensors / Actuators
| System Element | Function |
|---|---|
| Modicon Premium Controller | Executes machine and process control logic |
| TSXCPP110 | Provides CANopen master communication |
| CANopen Network | Transfers process and diagnostic data |
| CANopen Slave Nodes | Exchange data with the CANopen master |
| Distributed I/O | Interfaces field signals with the network |
| CANopen Drives | Receives motion or motor-control commands |
| Sensors / Actuators | Provide process feedback and perform physical actions |
| Engineering System | Supports configuration and commissioning |
This arrangement reduces the need for point-to-point wiring where distributed CANopen equipment is appropriate and gives the Premium controller a structured interface to networked field devices.
| Application | Typical Use |
|---|---|
| Machine Automation | CANopen networking between Premium PLC and field devices |
| Distributed I/O | Communication with remote I/O nodes |
| Motor Control | Interface to compatible CANopen drives |
| Packaging Machinery | Networking sensors, actuators, and distributed devices |
| Material Handling | CANopen communication for conveyor equipment |
| Assembly Systems | Coordinating distributed machine components |
| Manufacturing Equipment | Fieldbus connection for networked automation devices |
| Process Auxiliary Systems | Communication with distributed control equipment |
| OEM Machine Control | Integrating CANopen devices into Premium architectures |
| Component | Function |
|---|---|
| Modicon Premium Processor | Executes PLC control and sequencing logic |
| TSXCPP110 | Provides CANopen master communication |
| CANopen Network | Transfers data between controller and field nodes |
| CANopen Distributed I/O | Exchanges field signals through the network |
| CANopen Motor Drives | Provides networked motor-control interface |
| CANopen Sensors | Supplies measurement and status information |
| CANopen Actuator Interfaces | Receives commands for connected field equipment |
| CANopen Termination | Maintains appropriate network electrical conditions |
| Engineering Software | Supports PLC and communication configuration |
| Model / Product Family | Product Type | Typical Application |
|---|---|---|
| Schneider TSXCPP110 | CANopen Bus Master PCMCIA Card | Premium CANopen communication |
| Modicon Premium | PLC Platform | Machine and process control |
| Modicon Premium Processors | PLC Processor | Control logic and sequencing |
| Schneider CANopen Interfaces | CANopen Communication Products | Industrial fieldbus integration |
| Schneider CANopen I/O | Distributed I/O | Remote field signal interfacing |
| Schneider CANopen Drives | Motor Drive | Networked motor control |
| Modicon Premium Communication Modules | Communication Interface | Premium system networking |
The TSXCPP110 is a communication interface rather than a conventional discrete or analog I/O module. It exchanges configured data with CANopen network nodes, allowing distributed devices to communicate with the Premium controller over the fieldbus.
Check the TSXCPP110 installation and configuration first, followed by CANopen wiring, network termination, node addressing, device power, and communication status. If only one node is unavailable, that device and its local connection should receive particular attention.
It can be used as the CANopen master interface in architectures containing compatible CANopen devices, including networked drive equipment. The specific drive model, communication profile, configuration, and required process data should be verified before commissioning.
The PLC application and associated communication configuration should be preserved before replacement. Network node assignments, CANopen parameters, and device-specific settings should also be documented so the replacement card can be commissioned with the intended network configuration.